  Alibava/Mapsa testbeam at DESY in April 2017 (Axel, Grossi), Page 4 of 7  Not logged in ELOG logo
ID Date Author Project Subject Run Number Events XYPosition Cooling Datadown Text Attachments
  69   Fri Apr 14 17:22:52 2017 Axel KoenigALiBaVa (IFX)run_025_IFX_CB_150V.dat025175000109, 4.5, 240NoUnknown3Remarks: Telescope run 548. Bias scan
150 V.

  
  70   Fri Apr 14 18:22:58 2017 Axel KoenigALiBaVa (IFX)run_026_IFX_CB_100V.dat026350000109, 4.5, 230NoUnknownRemarks: Telescope run 549. Angle shift
230 deg.

  
  71   Fri Apr 14 19:43:13 2017 Axel KoenigALiBaVa (IFX)run_027_IFX_CB_100V.dat027350000109, 4.5, 250NoUnknownRemarks: Telescope run 550. Angle shift
250 deg.

  
  73   Sat Apr 15 09:57:51 2017 Axel KoenigALiBaVa (IFX)run_029_IFX_CB_130V.dat029175000109, 4.5, 240NoUnknown3Remarks: Telescope run 557. Bias scan
130 V.

  
  74   Sat Apr 15 12:12:00 2017 Axel KoenigALiBaVa (IFX)run_030_IFX_CB_100V.dat0301000000109, 4.5, 240NoUnknown3Remarks: Telescope run 558. Bias scan
100 V. Telescope chiller turned off. Could
be the root cause of crashing runs.
  
  75   Sat Apr 15 16:52:06 2017 Axel KoenigALiBaVa (IFX)run_001_Baby_100V.dat001250000102.5, 22.5, 240NoUnknownRemarks: Telescope run 562. Telescope chiller
turned off (could be the root cause of runs
crashing).
  
  76   Sat Apr 15 16:55:19 2017 Axel KoenigcommonChiller turned off!   NoUnknownThe chiller has been turned off beginning
of run_30_IFX_CB_100V.dat.

Set temperature was 15 C. Now it
  
  77   Sat Apr 15 17:38:58 2017 Axel KoenigALiBaVa (IFX)run_002_Baby_100V.dat002250000102.5, 12.5, 240NoUnknownRemarks: Telescope run 563. Telescope chiller
turned off (could be the root cause of runs
crashing).
  
  78   Sat Apr 15 18:31:14 2017 Axel KoenigALiBaVa (IFX)run_003_Baby_100V.dat003250000102.5, 32.5, 240NoUnknownRemarks: Telescope run 564. Telescope chiller
turned off (could be the root cause of runs
crashing).
  
  79   Sat Apr 15 19:20:34 2017 Axel KoenigALiBaVa (IFX)run_004_Baby_100V.dat004250000102.5, 22.5, 250NoUnknownRemarks: Telescope run 565. Telescope chiller
turned off (could be the root cause of runs
crashing).
  
  80   Sat Apr 15 20:12:41 2017 Axel KoenigALiBaVa (IFX)run_005_Baby_100V.dat005250000102.5, 22.5, 230NoUnknownRemarks: Telescope run 568. Telescope chiller
turned off (could be the root cause of runs
crashing).
  
  82   Sun Apr 16 13:15:55 2017 Axel KoenigALiBaVa (IFX)run_008_Baby_20V.dat008175000102.5, 22.5, 240NoUnknownRemarks: Telescope run 583. Bias scan 20
V. run crashed.

Telescope chiller turned off (could
  
  83   Sun Apr 16 15:44:35 2017 Axel KoenigALiBaVa (IFX)run_009_Baby_30V.dat009135000102.5, 22.5, 240NoUnknownRemarks: Telescope run 586. Bias scan 30
V.

Telescope chiller turned off (could
  
  84   Sun Apr 16 17:42:06 2017 Axel KoenigALiBaVa (IFX)run_010_Baby_40V.dat010135000102.5, 22.5, 240NoUnknownRemarks: Telescope run 587. Bias scan 40
V.

Telescope chiller turned off (could
  
  85   Sun Apr 16 18:25:59 2017 Axel KoenigALiBaVa (IFX)run_011_Baby_50V.dat011135000102.5, 22.5, 240NoUnknownRemarks: Telescope run 588. Bias scan 50
V.

Telescope chiller turned off (could
  
  86   Sun Apr 16 19:04:41 2017 Axel KoenigALiBaVa (IFX)run_012_Baby_60V.dat012135000102.5, 22.5, 240NoUnknownRemarks: Telescope run 589. Bias scan 60
V.

Telescope chiller turned off (could
  
  87   Sun Apr 16 19:46:01 2017 Axel KoenigALiBaVa (IFX)run_013_Baby_65V.dat013112000102.5, 22.5, 240NoUnknownRemarks: Telescope run 590. Bias scan 65
V.

Telescope chiller turned off (could
  
  88   Sun Apr 16 20:22:27 2017 Axel KoenigALiBaVa (IFX)run_014_Baby_70V.dat014250000102.5, 22.5, 240NoUnknownRemarks: Telescope run 591. Bias scan 70
V.

Telescope chiller turned off (could
  
  90   Sun Apr 16 21:43:15 2017 Axel KoenigALiBaVa (IFX)run_015_Baby_100V.dat0152500000102.5, 22.5, 240NoUnknownRemarks: Telescope run 592. Long run, bias
voltage 100 V. Long run finished without
any problems.
  
  91   Sun Apr 16 22:42:51 2017 Johannes GrossmannMaPSAHV_Scan38700NoUnknownChanged HV from 100V to 80 V

22:41 16.4.2017
  