  69   Fri Apr 14 17:22:52 2017 Axel KoenigALiBaVa (IFX)run_025_IFX_CB_150V.dat025175000109, 4.5, 240NoUnknown

3Remarks: Telescope run 548. Bias scan 150 V.

Parameter Value
Alibava run run_025_IFX_CB_150V.dat
Telescope run 548
Triggers 175000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -150
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  70   Fri Apr 14 18:22:58 2017 Axel KoenigALiBaVa (IFX)run_026_IFX_CB_100V.dat026350000109, 4.5, 230NoUnknown

Remarks: Telescope run 549. Angle shift 230 deg.

Parameter Value
Alibava run run_026_IFX_CB_100V.dat
Telescope run 549
Triggers 350000
Alibava trigger eff. ~59.8%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

230 deg

  71   Fri Apr 14 19:43:13 2017 Axel KoenigALiBaVa (IFX)run_027_IFX_CB_100V.dat027350000109, 4.5, 250NoUnknown

Remarks: Telescope run 550. Angle shift 250 deg.

Parameter Value
Alibava run run_027_IFX_CB_100V.dat
Telescope run 550
Triggers 350000
Alibava trigger eff. ~59.8%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

250 deg

  73   Sat Apr 15 09:57:51 2017 Axel KoenigALiBaVa (IFX)run_029_IFX_CB_130V.dat029175000109, 4.5, 240NoUnknown

3Remarks: Telescope run 557. Bias scan 130 V.

Parameter Value
Alibava run run_029_IFX_CB_130V.dat
Telescope run 557
Triggers 175000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -130
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  74   Sat Apr 15 12:12:00 2017 Axel KoenigALiBaVa (IFX)run_030_IFX_CB_100V.dat0301000000109, 4.5, 240NoUnknown

3Remarks: Telescope run 558. Bias scan 100 V. Telescope chiller turned off. Could be the root cause of crashing runs.

Parameter Value
Alibava run run_030_IFX_CB_100V.dat
Telescope run 558
Triggers 1000000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  75   Sat Apr 15 16:52:06 2017 Axel KoenigALiBaVa (IFX)run_001_Baby_100V.dat001250000102.5, 22.5, 240NoUnknown

Remarks: Telescope run 562. Telescope chiller turned off (could be the root cause of runs crashing).

Position: 102.5, 22.5, 240 (should be the center of the sensor).

Parameter Value
Alibava run run_001_Baby_100V.dat
Telescope run 562
Triggers 250000
Alibava trigger eff. ~93%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 102.5 mm
Table z 22.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  76   Sat Apr 15 16:55:19 2017 Axel KoenigcommonChiller turned off!   NoUnknown

The chiller has been turned off beginning of run_30_IFX_CB_100V.dat.

Set temperature was 15 C. Now it should settle at 20 +- 1 C (room temperature).

   
  77   Sat Apr 15 17:38:58 2017 Axel KoenigALiBaVa (IFX)run_002_Baby_100V.dat002250000102.5, 12.5, 240NoUnknown

Remarks: Telescope run 563. Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_002_Baby_100V.dat
Telescope run 563
Triggers 250000
Alibava trigger eff. ~93%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 102.5 mm
Table z 12.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  78   Sat Apr 15 18:31:14 2017 Axel KoenigALiBaVa (IFX)run_003_Baby_100V.dat003250000102.5, 32.5, 240NoUnknown

Remarks: Telescope run 564. Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_003_Baby_100V.dat
Telescope run 564
Triggers 250000
Alibava trigger eff. ~93%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 102.5 mm
Table z 32.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  79   Sat Apr 15 19:20:34 2017 Axel KoenigALiBaVa (IFX)run_004_Baby_100V.dat004250000102.5, 22.5, 250NoUnknown

Remarks: Telescope run 565. Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_004_Baby_100V.dat
Telescope run 565
Triggers 250000
Alibava trigger eff. ~93%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 102.5 mm
Table z 22.5 mm
Tabe rot

250 deg

  80   Sat Apr 15 20:12:41 2017 Axel KoenigALiBaVa (IFX)run_005_Baby_100V.dat005250000102.5, 22.5, 230NoUnknown

Remarks: Telescope run 568. Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_005_Baby_100V.dat
Telescope run 568
Triggers 250000
Alibava trigger eff. ~93%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 102.5 mm
Table z 22.5 mm
Tabe rot

230 deg

  82   Sun Apr 16 13:15:55 2017 Axel KoenigALiBaVa (IFX)run_008_Baby_20V.dat008175000102.5, 22.5, 240NoUnknown

Remarks: Telescope run 583. Bias scan 20 V. run crashed.

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_008_Baby_20V.dat
Telescope run 583
Triggers 175000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -20
Latency 132
Table x 102.5 mm
Table z 22.5 mm
Tabe rot

240 deg

  83   Sun Apr 16 15:44:35 2017 Axel KoenigALiBaVa (IFX)run_009_Baby_30V.dat009135000102.5, 22.5, 240NoUnknown

Remarks: Telescope run 586. Bias scan 30 V.

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_009_Baby_30V.dat
Telescope run 586
Triggers 135000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -30
Latency 132
Table x 102.5 mm
Table z 22.5 mm
Tabe rot

240 deg

  84   Sun Apr 16 17:42:06 2017 Axel KoenigALiBaVa (IFX)run_010_Baby_40V.dat010135000102.5, 22.5, 240NoUnknown

Remarks: Telescope run 587. Bias scan 40 V.

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_010_Baby_40V.dat
Telescope run 587
Triggers 135000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -40
Latency 132
Table x 102.5 mm
Table z 22.5 mm
Tabe rot

240 deg

  85   Sun Apr 16 18:25:59 2017 Axel KoenigALiBaVa (IFX)run_011_Baby_50V.dat011135000102.5, 22.5, 240NoUnknown

Remarks: Telescope run 588. Bias scan 50 V.

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_011_Baby_50V.dat
Telescope run 588
Triggers 135000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -50
Latency 132
Table x 102.5 mm
Table z 22.5 mm
Tabe rot

240 deg

  86   Sun Apr 16 19:04:41 2017 Axel KoenigALiBaVa (IFX)run_012_Baby_60V.dat012135000102.5, 22.5, 240NoUnknown

Remarks: Telescope run 589. Bias scan 60 V.

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_012_Baby_60V.dat
Telescope run 589
Triggers 135000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -60
Latency 132
Table x 102.5 mm
Table z 22.5 mm
Tabe rot

240 deg

  87   Sun Apr 16 19:46:01 2017 Axel KoenigALiBaVa (IFX)run_013_Baby_65V.dat013112000102.5, 22.5, 240NoUnknown

Remarks: Telescope run 590. Bias scan 65 V.

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_013_Baby_65V.dat
Telescope run 590
Triggers 112000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -65
Latency 132
Table x 102.5 mm
Table z 22.5 mm
Tabe rot

240 deg

  88   Sun Apr 16 20:22:27 2017 Axel KoenigALiBaVa (IFX)run_014_Baby_70V.dat014250000102.5, 22.5, 240NoUnknown

Remarks: Telescope run 591. Bias scan 70 V.

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_014_Baby_70V.dat
Telescope run 591
Triggers 250000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -70
Latency 132
Table x 102.5 mm
Table z 22.5 mm
Tabe rot

240 deg

  90   Sun Apr 16 21:43:15 2017 Axel KoenigALiBaVa (IFX)run_015_Baby_100V.dat0152500000102.5, 22.5, 240NoUnknown

Remarks: Telescope run 592. Long run, bias voltage 100 V. Long run finished without any problems.

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_015_Baby_100V.dat
Telescope run 592
Triggers 2500000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 102.5 mm
Table z 22.5 mm
Tabe rot

240 deg

  91   Sun Apr 16 22:42:51 2017 Johannes GrossmannMaPSAHV_Scan38700NoUnknown

Changed HV from 100V to 80 V

22:41 16.4.2017

ELOG V3.1.5-fc6679b