Fri Apr 14 17:22:52 2017, Axel Koenig, ALiBaVa (IFX), run_025_IFX_CB_150V.dat, 025, 175000, 109, 4.5, 240, No, Unknown
|
3Remarks: Telescope run 548. Bias scan 150 V.
Parameter
Value
Alibava run
run_025_IFX_CB_150V.dat
|
Fri Apr 14 18:22:58 2017, Axel Koenig, ALiBaVa (IFX), run_026_IFX_CB_100V.dat, 026, 350000, 109, 4.5, 230, No, Unknown
|
Remarks: Telescope run 549. Angle shift 230 deg.
Parameter
Value
Alibava run
run_026_IFX_CB_100V.dat
|
Fri Apr 14 19:43:13 2017, Axel Koenig, ALiBaVa (IFX), run_027_IFX_CB_100V.dat, 027, 350000, 109, 4.5, 250, No, Unknown
|
Remarks: Telescope run 550. Angle shift 250 deg.
Parameter
Value
Alibava run
run_027_IFX_CB_100V.dat
|
Sat Apr 15 09:57:51 2017, Axel Koenig, ALiBaVa (IFX), run_029_IFX_CB_130V.dat, 029, 175000, 109, 4.5, 240, No, Unknown
|
3Remarks: Telescope run 557. Bias scan 130 V.
Parameter
Value
Alibava run
run_029_IFX_CB_130V.dat
|
Sat Apr 15 12:12:00 2017, Axel Koenig, ALiBaVa (IFX), run_030_IFX_CB_100V.dat, 030, 1000000, 109, 4.5, 240, No, Unknown
|
3Remarks: Telescope run 558. Bias scan 100 V. Telescope chiller turned off. Could be the root cause of crashing runs.
Parameter
Value
Alibava run
run_030_IFX_CB_100V.dat
|
Sat Apr 15 16:52:06 2017, Axel Koenig, ALiBaVa (IFX), run_001_Baby_100V.dat, 001, 250000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 562. Telescope chiller turned off (could be the root cause of runs crashing).
Position: 102.5, 22.5, 240 (should be the center of the sensor).
Parameter
|
Sat Apr 15 16:55:19 2017, Axel Koenig, common, Chiller turned off!, , , , No, Unknown
|
The chiller has been turned off beginning of run_30_IFX_CB_100V.dat.
Set temperature was 15 C. Now it should settle at 20 +- 1 C (room temperature).
|
Sat Apr 15 17:38:58 2017, Axel Koenig, ALiBaVa (IFX), run_002_Baby_100V.dat, 002, 250000, 102.5, 12.5, 240, No, Unknown
|
Remarks: Telescope run 563. Telescope chiller turned off (could be the root cause of runs crashing).
Parameter
Value
Alibava run
run_002_Baby_100V.dat
|
Sat Apr 15 18:31:14 2017, Axel Koenig, ALiBaVa (IFX), run_003_Baby_100V.dat, 003, 250000, 102.5, 32.5, 240, No, Unknown
|
Remarks: Telescope run 564. Telescope chiller turned off (could be the root cause of runs crashing).
Parameter
Value
Alibava run
run_003_Baby_100V.dat
|
Sat Apr 15 19:20:34 2017, Axel Koenig, ALiBaVa (IFX), run_004_Baby_100V.dat, 004, 250000, 102.5, 22.5, 250, No, Unknown
|
Remarks: Telescope run 565. Telescope chiller turned off (could be the root cause of runs crashing).
Parameter
Value
Alibava run
run_004_Baby_100V.dat
|
Sat Apr 15 20:12:41 2017, Axel Koenig, ALiBaVa (IFX), run_005_Baby_100V.dat, 005, 250000, 102.5, 22.5, 230, No, Unknown
|
Remarks: Telescope run 568. Telescope chiller turned off (could be the root cause of runs crashing).
Parameter
Value
Alibava run
run_005_Baby_100V.dat
|
Sun Apr 16 13:15:55 2017, Axel Koenig, ALiBaVa (IFX), run_008_Baby_20V.dat, 008, 175000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 583. Bias scan 20 V. run crashed.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter
|
Sun Apr 16 15:44:35 2017, Axel Koenig, ALiBaVa (IFX), run_009_Baby_30V.dat, 009, 135000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 586. Bias scan 30 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter
|
Sun Apr 16 17:42:06 2017, Axel Koenig, ALiBaVa (IFX), run_010_Baby_40V.dat, 010, 135000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 587. Bias scan 40 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter
|
Sun Apr 16 18:25:59 2017, Axel Koenig, ALiBaVa (IFX), run_011_Baby_50V.dat, 011, 135000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 588. Bias scan 50 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter
|
Sun Apr 16 19:04:41 2017, Axel Koenig, ALiBaVa (IFX), run_012_Baby_60V.dat, 012, 135000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 589. Bias scan 60 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter
|
Sun Apr 16 19:46:01 2017, Axel Koenig, ALiBaVa (IFX), run_013_Baby_65V.dat, 013, 112000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 590. Bias scan 65 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter
|
Sun Apr 16 20:22:27 2017, Axel Koenig, ALiBaVa (IFX), run_014_Baby_70V.dat, 014, 250000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 591. Bias scan 70 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter
|
Sun Apr 16 21:43:15 2017, Axel Koenig, ALiBaVa (IFX), run_015_Baby_100V.dat, 015, 2500000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 592. Long run, bias voltage 100 V. Long run finished without any problems.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter
|
Sun Apr 16 22:42:51 2017, Johannes Grossmann, MaPSA, HV_Scan, 387, 0, 0, No, Unknown
|
Changed HV from 100V to 80 V
22:41 16.4.2017 |
|