ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
XYPosition |
Cooling |
Data |
88
|
Sun Apr 16 20:22:27 2017 |
Axel Koenig | ALiBaVa (IFX) | run_014_Baby_70V.dat | 014 | 250000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 591. Bias scan 70 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_014_Baby_70V.dat |
Telescope run |
591 |
Triggers |
250000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-70 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
90
|
Sun Apr 16 21:43:15 2017 |
Axel Koenig | ALiBaVa (IFX) | run_015_Baby_100V.dat | 015 | 2500000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 592. Long run, bias voltage 100 V. Long run finished without any problems.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_015_Baby_100V.dat |
Telescope run |
592 |
Triggers |
2500000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
92
|
Mon Apr 17 08:14:24 2017 |
Axel Koenig | ALiBaVa (IFX) | run_016_Baby_75V.dat | 016 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 593. Bias scan 75 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_016_Baby_75V.dat |
Telescope run |
593 |
Triggers |
112000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-75 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
93
|
Mon Apr 17 09:01:09 2017 |
Axel Koenig | ALiBaVa (IFX) | run_017_Baby_80V.dat | 017 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 594. Bias scan 80 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_017_Baby_80V.dat |
Telescope run |
594 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-80 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
94
|
Mon Apr 17 09:04:02 2017 |
Axel Koenig | ALiBaVa (IFX) | run_006_Baby_100V.dat | 006 | k.a. | 102.5, 22.5, 230 | No | Unknown |
Remarks: Telescope run 570. Telescope chiller turned off (could be the root cause of runs crashing).
Forgot ro record data in elog.
Parameter |
Value |
Alibava run |
run_006_Baby_100V.dat |
Telescope run |
570 |
Triggers |
k.a. |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
230 deg
|
|
95
|
Mon Apr 17 09:29:40 2017 |
Axel Koenig | ALiBaVa (IFX) | run_018_Baby_90V.dat | 018 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 595. Bias scan 90 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_018_Baby_90V.dat |
Telescope run |
595 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-90 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
96
|
Mon Apr 17 10:05:57 2017 |
Axel Koenig | ALiBaVa (IFX) | run_019_Baby_110V.dat | 019 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 596. Bias scan 110 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_019_Baby_110V.dat |
Telescope run |
596 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-110 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
99
|
Mon Apr 17 10:36:22 2017 |
Axel Koenig | ALiBaVa (IFX) | run_020_Baby_120V.dat | 020 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 597. Bias scan 120 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_020_Baby_120V.dat |
Telescope run |
597 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-120 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
100
|
Mon Apr 17 11:04:40 2017 |
Axel Koenig | ALiBaVa (IFX) | run_021_Baby_130V.dat | 021 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 598. Bias scan 130 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_021_Baby_130V.dat |
Telescope run |
598 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-130 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
101
|
Mon Apr 17 11:34:55 2017 |
Axel Koenig | ALiBaVa (IFX) | run_022_Baby_140V.dat | 022 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 599. Bias scan 140 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_022_Baby_140V.dat |
Telescope run |
599 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-140 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
104
|
Mon Apr 17 12:06:11 2017 |
Axel Koenig | ALiBaVa (IFX) | run_023_Baby_150V.dat | 023 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 600. Bias scan 150 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_023_Baby_150V.dat |
Telescope run |
600 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-150 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
105
|
Mon Apr 17 13:30:01 2017 |
Axel Koenig | ALiBaVa (IFX) | run_001_HPK_CB_200V.dat | 001 | 450000 | 107, 0, 240 | No | Unknown |
Remarks: Telescope run 604. Bias scan 200 V. Only one chip.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_001_HPK_CB_200V.dat |
Telescope run |
604 |
Triggers |
450000 |
Alibava trigger eff. |
~64% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
0 mm |
Tabe rot |
240 deg
|
|
106
|
Mon Apr 17 16:36:56 2017 |
Axel Koenig | ALiBaVa (IFX) | run_002_HPK_CB_200V.dat | 002 | 450000 | 107, 5.8, 240 | No | Unknown |
Remarks: Telescope run 605. Bias scan 200 V. Only one chip.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_002_HPK_CB_200V.dat |
Telescope run |
605 |
Triggers |
450000 |
Alibava trigger eff. |
~64% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
5.8 mm |
Tabe rot |
240 deg
|
|
107
|
Mon Apr 17 17:02:34 2017 |
Axel Koenig | ALiBaVa (IFX) | run_003_HPK_CB_200V.dat | 003 | 250000 | 107, 2.6, 230 | No | Unknown |
Remarks: Telescope run 606. Angle scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_003_HPK_CB_200V.dat |
Telescope run |
606 |
Triggers |
250000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
230 deg
|
|
109
|
Mon Apr 17 17:46:38 2017 |
Axel Koenig | ALiBaVa (IFX) | run_005_HPK_CB_50V.dat | 005 | 150000 | 107, 2.6, 240 | No | Unknown |
Remarks: Telescope run 609. Bias scan 50 V. Bias scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_005_HPK_CB_50V.dat |
Telescope run |
609 |
Triggers |
150000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-50 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
240 deg
|
|
111
|
Mon Apr 17 19:19:14 2017 |
Axel Koenig | ALiBaVa (IFX) | run_006_HPK_CB_100V.dat | 006 | 150000 | 107, 2.6, 240 | No | Unknown |
Remarks: Telescope run 610. Bias scan 100 V. Bias scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_006_HPK_CB_100V.dat |
Telescope run |
610 |
Triggers |
150000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
240 deg
|
|
113
|
Mon Apr 17 19:54:08 2017 |
Axel Koenig | ALiBaVa (IFX) | run_007_HPK_CB_150V.dat | 007 | 300000 | 107, 2.6, 240 | No | Unknown |
Remarks: Telescope run 611. Bias scan 150 V. Bias scan. Run crashed at 294000 triggers!
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_007_HPK_CB_150V.dat |
Telescope run |
611 |
Triggers |
300000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-150 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
240 deg
|
|
114
|
Mon Apr 17 21:52:45 2017 |
Axel Koenig | ALiBaVa (IFX) | run_008_HPK_CB_250V.dat | 008 | 150000 | 107, 2.6, 240 | No | Unknown |
Remarks: Telescope run 613. Bias scan 250 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_008_HPK_CB_250V.dat |
Telescope run |
613 |
Triggers |
150000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-250 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
240 deg
|
|
115
|
Mon Apr 17 22:27:44 2017 |
Axel Koenig | ALiBaVa (IFX) | run_009_HPK_CB_200V.dat | 009 | 2400000 | 107, 2.6, 240 | No | Unknown |
Remarks: Telescope run 614. Long run over night. run crashed over night!
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_009_HPK_CB_200V.dat |
Telescope run |
614 |
Triggers |
2400000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
240 deg
|
|
118
|
Tue Apr 18 08:04:39 2017 |
Axel Koenig | ALiBaVa (IFX) | run_004_HPK_CB_200V.dat | 004 | 250000 | 107, 2.6, 250 | No | Unknown |
Remarks: Telescope run 607. Angle scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_004_HPK_CB_200V.dat |
Telescope run |
607 |
Triggers |
250000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
250 deg
|
|