Home CMS Production Clean room MedAustron HEPHY testbeams old
electronics module assembly SiDDaTA scratch
  HEPHY logbook of the Electronics Group, Page 4 of 4  Not logged in ELOG logo
Entry  Wed May 20 10:12:12 2015, Hao Yin, , , , Ladder RLC test (CMC Injection) 
L5 Ladder Test

folder: /mnt/data/ITA_NOISE_TESTS/Ladder_test

Setup: ladder only, noise injection on one hybrid (injection point = cable between hybrid and junction board, see attachment
Entry  Thu May 21 18:23:22 2015, Hao Yin, , , , Noise Injection LV cable P1000717.JPG
(TestNr. 15)

injecting sin wave into LV at different frequencies to analyse the output frequency and noise ground level after the junction borad.
Entry  Fri May 22 12:01:32 2015, Hao Yin, , , , CMC injection LV 10V 
Comparison w/o filter (LC) connected to -z_n side.

Mateo has the results.
Entry  Mon Nov 30 15:12:19 2015, Hao Yin, , , , FIR_ADC config 
FIR filter and ADC delay test:
ADC delay and FIR filter with and without cooling to reproduce error detected during CERN beam test 2015.
 
ELOG V3.1.5-fc6679b