Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
electronics
module assembly
SiDDaTA
scratch
HEPHY logbook of the Electronics Group, Page 2 of 4
Not logged in
Find
|
Select
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Type --
Common
Measurement
-- Project --
SPS Testbeam June08
Belle II
PixelFED
-- Measurement Type --
hybrid
module
source
system
64 Entries
Goto page
Previous
1
, 2,
3
,
4
Next
All
Selected entries:
Tracker Sensor QC
HGC Sensor QC
Process QC
Longterm
Visual Inspection
Process QC OLD
SQC
PQC
P3
HGC
Klimakammer
microscopes
infrastructure
test
cleanroom
lasersetup
module assembly
testbeam-MA2023
testbeam-MA2021
testbeam-MA2020
testbeam-MA2019
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
SiDDaTA
scratch
testbeam-MA2018
testbeam-MA2024
ID
Date
Author
Project
Measurement Type
Object ID
Subject
Text
2
Tue Apr 22 19:34:09 2008
Markus Friedl
SPS Testbeam June08
module
hybrid 01
Properties of hybrid 01, sensor fully bonded, HV=100V
HV bias glued to backplane, HV=100V
6x
40
Tue May 19 11:01:29 2015
Hao Yin
Belle II
system
Pedestal
PedestalRun
FIRRun001
Baseline measurement without injections,
50000 event,
16x
1
Fri Apr 18 17:23:26 2008
Markus Friedl
SPS Testbeam June08
hybrid
hybrid 01
Noise of hybrid 01, sensor fully bonded, no HV
HV bias not yet glued to backplane
37
Tue May 19 09:31:50 2015
Hao Yin
Noise Test ITA
Everything works except L3 p-side.
The config file is shown in the
following:
45
Thu May 21 18:23:22 2015
Hao Yin
Noise Injection LV cable
(TestNr. 15)
injecting sin wave into LV at different
32
Fri May 16 11:40:29 2014
Benedikt Würkner
Belle II
source
L3 module
No 6 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: -54:-10(bottom right)
10x
23
Wed May 7 18:20:36 2014
Benedikt Würkner
Belle II
source
L3 module
No 6 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -57:-30(bottom right)
10x
31
Fri May 16 11:38:44 2014
Benedikt Würkner
Belle II
source
L3 module
No 5 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: -27:-10(bottom center)
10x
22
Wed May 7 17:33:21 2014
Benedikt Würkner
Belle II
source
L3 module
No 5 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -32:-30(bottom center)
10x
30
Fri May 16 11:37:05 2014
Benedikt Würkner
Belle II
source
L3 module
No 4 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: 0:-10(bottom left)
10x
21
Wed May 7 16:43:37 2014
Benedikt Würkner
Belle II
source
L3 module
No 4 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -5:-30(bottom left)
10x
29
Fri May 9 16:44:41 2014
Benedikt Würkner
Belle II
source
L3 module
No 3 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: -54:0(top center)
10x
20
Wed May 7 15:53:38 2014
Benedikt Würkner
Belle II
source
L3 module
No 3 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -59:-20(top right)
10x
27
Thu May 8 16:51:57 2014
Benedikt Würkner
Belle II
source
L3 module
No 2 of 6 room temperature measurements using Sr90 Source (single)
Failed with Error: "***ERROR*** Init
NECO failed, Return code: -32761"
Restarted and it works again
28
Fri May 9 15:12:44 2014
Benedikt Würkner
Belle II
source
L3 module
No 2 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: -27:0(top center)
10x
19
Wed May 7 15:04:32 2014
Benedikt Würkner
Belle II
source
L3 module
No 2 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -32:-20(top center)
10x
26
Thu May 8 16:51:03 2014
Benedikt Würkner
Belle II
source
L3 module
No 1 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: 0:0(top left)
10x
18
Wed May 7 14:36:29 2014
Benedikt Würkner
Belle II
source
L3 module
No 1 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -5:-20(top left)
10x
44
Wed May 20 10:12:12 2015
Hao Yin
Ladder RLC test (CMC Injection)
L5 Ladder Test
folder: /mnt/data/ITA_NOISE_TESTS/Ladder_test
Setup: ladder
42
Tue May 19 13:42:04 2015
Hao Yin
L6 Noise inJection Setup
Test Nr. 1:
RLC between DockBox and Hybrid
(both side).
Goto page
Previous
1
, 2,
3
,
4
Next
All
ELOG V3.1.5-fc6679b