Tue May 19 14:48:06 2015, Hao Yin, Belle II, module, L6 Noise inJection Runs, L6 Noise inJection Runs
|
Folder "L6_RLC_Test"
Configuration file: /mnt/data/ITA_NOISE_TESTS/L6_RLC_Test/SinglePeak_3Fadc.cfg
3 Tests: Injkection to 2.5V 1.25V. ground and their combination |
Mon Nov 30 15:18:12 2015, Hao Yin, Belle II, module, ADC_DELAY_HOT, ADC delay hot
|
ADC delay scan at room temp and 20 min after APV I2C config.
measured values at display in the FIR_HOT cfg file.
17:06 first run 20 min after i2c config. |
Mon Nov 30 17:11:17 2015, Hao Yin, Belle II, module, FIRRun001, FIRRun001 aft ADC_HOT
|
FirRun 20 min after I2C |
Wed Apr 23 13:05:05 2008, Christian Irmler, SPS Testbeam June08, source, hybrid 01, time correlation between TDC and sensor measurement -> 3.1 ns RMS
|
|
Wed Apr 23 13:37:18 2008, Markus Friedl, SPS Testbeam June08, source, hybrid 01, analysis results of source test
|
Ignore the "KEK November 2007" title - that's a legacy and is already changed :-)
As of now, there is no distinction in 16 separate zones. However, the gaps between the the zones are clearly visible in the Hit Profile, as the edge strips |
Tue May 20 14:27:50 2008, Markus Friedl, BELLE Upgrade, source, micron, analysis results of source test 9x
|
*** NOTE: AFTER THIS MEASUREMENT WE REALIZED THAT BIASING WAS NOT DONE PROPERLY
HENCE THE RESULTS BELOW ARE NOT RELIABLE
|
Sun Jul 4 05:48:36 2010, Christian Irmler, BELLE Upgrade, source, Origami 6 - module 1, run002: first analysis results 7x
|
Run name: run002
Run type: 0 (Hardware (Normal Run)) |
Wed May 7 14:36:29 2014, Benedikt Würkner, Belle II, source, L3 module, No 1 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -5:-20(top left) |
Wed May 7 15:04:32 2014, Benedikt Würkner, Belle II, source, L3 module, No 2 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -32:-20(top center) |
Wed May 7 15:53:38 2014, Benedikt Würkner, Belle II, source, L3 module, No 3 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -59:-20(top right) |
Wed May 7 16:43:37 2014, Benedikt Würkner, Belle II, source, L3 module, No 4 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -5:-30(bottom left) |
Wed May 7 17:33:21 2014, Benedikt Würkner, Belle II, source, L3 module, No 5 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -32:-30(bottom center) |
Wed May 7 18:20:36 2014, Benedikt Würkner, Belle II, source, L3 module, No 6 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -57:-30(bottom right) |
Thu May 8 16:51:03 2014, Benedikt Würkner, Belle II, source, L3 module, No 1 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: 0:0(top left) |
Thu May 8 16:51:57 2014, Benedikt Würkner, Belle II, source, L3 module, No 2 of 6 room temperature measurements using Sr90 Source (single)
|
Failed with Error: "***ERROR*** Init NECO failed, Return code: -32761"
Restarted and it works again
Sr90 Radioactive Source |
Fri May 9 15:12:44 2014, Benedikt Würkner, Belle II, source, L3 module, No 2 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -27:0(top center) |
Fri May 9 16:44:41 2014, Benedikt Würkner, Belle II, source, L3 module, No 3 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -54:0(top center) |
Fri May 16 11:37:05 2014, Benedikt Würkner, Belle II, source, L3 module, No 4 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: 0:-10(bottom left) |
Fri May 16 11:38:44 2014, Benedikt Würkner, Belle II, source, L3 module, No 5 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -27:-10(bottom center) |
Fri May 16 11:40:29 2014, Benedikt Würkner, Belle II, source, L3 module, No 6 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -54:-10(bottom right) |