64 Entries
Goto page
Previous
1
, 2,
3
,
4
Next
All
ID
Date
Author
Project
Measurement Type
Object ID
Subject
Text
40
Tue May 19 11:01:29 2015
Hao Yin
Belle II
system
Pedestal
PedestalRun
FIRRun001
Baseline measurement without injections,
50000 event,
16x
50
Fri May 29 11:47:56 2015
Hao Yin
Belle II
system
PS Filter
Testing PS LV filter and quantifying the required min noise lvl
Data of this entry is recorded in the folder:
LV315kHz_Injections
Injecting noise to LV with a freq.
17
Sun Jul 4 05:48:36 2010
Christian Irmler
BELLE Upgrade
source
Origami 6 - module 1
run002: first analysis results
Run name: run002
Run type: 0 (Hardware (Normal Run))
7x
43
Tue May 19 14:48:06 2015
Hao Yin
Belle II
module
L6 Noise inJection Runs
L6 Noise inJection Runs
Folder "L6_RLC_Test"
Configuration file: /mnt/data/ITA_NOISE_TESTS/L6_RLC_Test/SinglePeak_3Fadc.cfg
3 Tests: Injkection to 2.5V 1.25V.
47
Mon May 25 10:38:03 2015
Hao Yin
Belle II
system
L5 Ladder Emission Test
Emission
(TestNr: 16)
base line noise measurement are
saved in SYSTEM_CHECK_AFTER_WE.
18
Wed May 7 14:36:29 2014
Benedikt Würkner
Belle II
source
L3 module
No 1 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -5:-20(top left)
10x
19
Wed May 7 15:04:32 2014
Benedikt Würkner
Belle II
source
L3 module
No 2 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -32:-20(top center)
10x
20
Wed May 7 15:53:38 2014
Benedikt Würkner
Belle II
source
L3 module
No 3 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -59:-20(top right)
10x
21
Wed May 7 16:43:37 2014
Benedikt Würkner
Belle II
source
L3 module
No 4 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -5:-30(bottom left)
10x
22
Wed May 7 17:33:21 2014
Benedikt Würkner
Belle II
source
L3 module
No 5 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -32:-30(bottom center)
10x
23
Wed May 7 18:20:36 2014
Benedikt Würkner
Belle II
source
L3 module
No 6 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -57:-30(bottom right)
10x
26
Thu May 8 16:51:03 2014
Benedikt Würkner
Belle II
source
L3 module
No 1 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: 0:0(top left)
10x
27
Thu May 8 16:51:57 2014
Benedikt Würkner
Belle II
source
L3 module
No 2 of 6 room temperature measurements using Sr90 Source (single)
Failed with Error: "***ERROR*** Init
NECO failed, Return code: -32761"
Restarted and it works again
28
Fri May 9 15:12:44 2014
Benedikt Würkner
Belle II
source
L3 module
No 2 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: -27:0(top center)
10x
29
Fri May 9 16:44:41 2014
Benedikt Würkner
Belle II
source
L3 module
No 3 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: -54:0(top center)
10x
30
Fri May 16 11:37:05 2014
Benedikt Würkner
Belle II
source
L3 module
No 4 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: 0:-10(bottom left)
10x
31
Fri May 16 11:38:44 2014
Benedikt Würkner
Belle II
source
L3 module
No 5 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: -27:-10(bottom center)
10x
32
Fri May 16 11:40:29 2014
Benedikt Würkner
Belle II
source
L3 module
No 6 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: -54:-10(bottom right)
10x
62
Mon Nov 30 19:48:05 2015
Hao Yin
Belle II
system
Hardware_Room_With_Cold_I2C
ADC Cold diff to hot: 1-3 adc delay config
(max 1.5 ns), FIRRun_Cold_001
with room temp i2c config
63
Mon Nov 30 20:06:15 2015
Hao Yin
Belle II
system
Hardware_Room_With_Cold_I2C
ADC Cold diff to hot: 1-3 adc delay config
(max 1.5 ns), FIRRun_Cold_001
with room temp i2c config