Message ID: 17
Entry time: Sun Jul 4 05:48:36 2010
|
Type: |
Measurement |
Author: |
Christian Irmler |
Project: |
BELLE Upgrade |
Subject: |
run002: first analysis results |
Object ID: |
Origami 6 - module 1 |
Measurement Type: |
source |
Run Number: |
|
|
|
Run name: run002
Run type: 0 (Hardware (Normal Run))
Comments:
After ~40min warmup
HV=80
90Sr 1mCi source - moved compared to run001
multi6
Max. Events=100000 Trg delay=25
Origami 6 module #1
w/o cooling
sensor: B2HPK_10938-9239_8
n-side: all 4 APVs read out
p-side: APV #0 to #3 read out, analog output of #4 and #5 were not connected to FADC board
|
|
Analysis of run002
Peak Mode, 3 x 200 initevents (first 10 skipped) + 99400 events
Number hybrids: 2 number zones: 2 number sensors: 1
Using calibration file intcal001
No pedestal correction file
Seed/Neighbor/Cluster/Noisy Strips Cuts [RMS noise]: 5.0/3.0/5.0
Min. hitlength: 3
Comments:
After ~40min warmup
HV=80
90Sr 1mCi source - moved compared to run001
multi6
Analysis date: 04.07.2010 05:40:47
Analysis settings:
runname: run002_cluster
clock: 40.00 MHz
datafilepath: ./
outputpath: ./
subevents: 6
fitmode: 2 (cal. fit)
options: hr
Results:
ModuleName ZoneType Ch OKCh OK% Entries MClW MPSignal Noise MPSNR HpSE Occup SigSlop SigInt SigRes PtiSlop PtiInt PtiRes ClwSlop ClwInt ClwRes
Origami6_mod1_p Orgami 6" 512 512 100.0 34659 1.87 24436.5 3330.4 6.74 0.25 0.80 0.95 0.00 6651.0 1.00 -17.63 7.47 1.00 0.21 0.86
Origami6_mod1_n Orgami 6" 512 508 99.2 95601 1.93 23801.7 962.7 17.08 1.02 0.79 0.95 0.00 6651.0 1.00 -17.63 7.47 1.00 0.21 0.86
|
|
|
|
|
|
|