Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in October 2024, Page 28 of 29  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject Run Numberdown DUT Biasing Beam Energy thr HV scan-val Data t-Start t-Stop Duration_min Text Attachments
  233   Thu Oct 3 18:21:31 2024 tb-crewinceasing bias V W8-1E15Topside4.20.97-540 Unknown   bias = 0
setting voltage manually now
approaching regimes in which compliance starts
  
  232   Thu Oct 3 18:21:31 2024 tb-crewinceasing bias V W8-1E15Topside4.20.97-540 Unknown   bias = 0
setting voltage manually now
approaching regimes in which compliance starts
  
  234   Thu Oct 3 18:49:47 2024 tb-crewinceasing bias V W8-1E15Topside4.2   Unknown   might have killed it, being very cautious
now
  
  238   Thu Oct 3 22:08:26 2024 tb-crewinceasing bias V W8-1E15Topside4.20.97-30 Unknown   did kill it :(   
  239   Thu Oct 3 22:36:37 2024 tb-crew  V W3-1E14Topside4.20.97-30 Unknown   changed DUT again for backside bias scan   
  247   Thu Oct 3 23:27:16 2024 tb-crewHV scan V W3-1E14Backside4.21.1-480 Unknown   frgot to unmask from 1E15; done now   
  299   Fri Oct 4 08:34:23 2024 tb-crewVNFB scan V W3-1E14Backside4.21.1-50030Unknown   no tel data in last 3 runs   
  301   Fri Oct 4 08:39:59 2024 tb-crewVNFB scan V W3-1E14Backside4.2   Unknown   had to restart EUDAQ, no telepix now (can't
reach GUI remotely)
  
  303   Fri Oct 4 08:42:13 2024 tb-crewVNFB scan V W3-1E14Backside4.21.1-50030Unknown   back with actual DAC scan   
  308   Fri Oct 4 09:31:31 2024 tb-crewVNFB scan V W3-1E14Backside4.21.1-50060Unknown   we're missing telescope data from Run 269
-> 272
repeating these scans
  
  311   Fri Oct 4 09:47:09 2024 tb-crewVNFB scan V W3-1E14Backside4.21.1-50010Unknown   we we're running with too high of  a bias
voltage
we want -190V for these scans
  
  318   Fri Oct 4 11:40:00 2024 tb-crew  L W3-3E14Backside4.2   Unknown   changed to next (LAST) DUT   
  319   Fri Oct 4 11:56:16 2024 tb-crewstd settings L W3-3E14Backside4.21.1-19018Unknown   we'll have to move the stage a bit, not very
centered
  
Entry is currently edited by Bernhard Pilsl on 192.76.172.198    321   Fri Oct 4 12:02:37 2024 tb-crewcentering DUT L W3-3E14Backside4.2   Unknown   currently at 
positionX = 54.5
positionY = 11
  
  327   Fri Oct 4 12:28:37 2024 tb-crewcentering DUT L W3-3E14Backside4.21.1-190 Unknown   currently at 
positionX = 56
positionY = 11.5
  
  398   Sat Oct 5 09:26:25 2024 tb-crewHV scan L W3-3E14Backside4.20.95-10 Unknown   telepix said ciao at run 362   
  399   Sat Oct 5 09:26:43 2024 tb-crew  L W3-3E14Topside4.20.95-10 Unknown   Moving jumper   
  462   Sat Oct 5 23:32:15 2024 tb-crewHV scan V W8-0E0Topside4.2   Unknown   changed DUT   
  527   Sun Oct 6 10:06:40 2024 tb-crewalignment V W8-0E0Topside4.21.0-280 Unknown   positionX = 55   # DUT measurement position
positionY = 11.5   # mm
  
  528   Sun Oct 6 10:28:57 2024 tb-crew  V W8-0E0Topside4.21.0-280 Unknown   full efficiency achived :D   
ELOG V3.1.5-fc6679b