Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
Testbeam at DESY in October 2024, Page 28 of 29
Not logged in
Find
|
Login
|
Help
Full |
Summary
|
Threaded
|
Hide attachments
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
V W8-0E0
V W3-1E14
L W3-3E14
V W8-1E15
L W3-3E15
V W3-1W16
L W3-3E16
-- Beam Energy --
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
3.8
4.0
4.2
4.4
4.6
4.8
5.0
5.2
5.4
5.6
5.8
6.0
564 Entries
Goto page
Previous
1
,
2
,
3
...
27
, 28,
29
Next
ID
Date
Author
Subject
Run Number
DUT
Biasing
Beam Energy
thr
HV
scan-val
Data
t-Start
t-Stop
Duration_min
233
Thu Oct 3 18:21:31 2024
tb-crew
inceasing bias
V W8-1E15
Topside
4.2
0.97
-540
Unknown
bias = 0
setting voltage manually now
approaching regimes in which compliance starts to drip all the time
232
Thu Oct 3 18:21:31 2024
tb-crew
inceasing bias
V W8-1E15
Topside
4.2
0.97
-540
Unknown
bias = 0
setting voltage manually now
approaching regimes in which compliance starts to drip all the time
234
Thu Oct 3 18:49:47 2024
tb-crew
inceasing bias
V W8-1E15
Topside
4.2
Unknown
might have killed it, being very cautious now
238
Thu Oct 3 22:08:26 2024
tb-crew
inceasing bias
V W8-1E15
Topside
4.2
0.97
-30
Unknown
did kill it
239
Thu Oct 3 22:36:37 2024
tb-crew
V W3-1E14
Topside
4.2
0.97
-30
Unknown
changed DUT again for backside bias scan
247
Thu Oct 3 23:27:16 2024
tb-crew
HV scan
V W3-1E14
Backside
4.2
1.1
-480
Unknown
frgot to unmask from 1E15; done now
299
Fri Oct 4 08:34:23 2024
tb-crew
VNFB scan
V W3-1E14
Backside
4.2
1.1
-500
30
Unknown
no tel data in last 3 runs
301
Fri Oct 4 08:39:59 2024
tb-crew
VNFB scan
V W3-1E14
Backside
4.2
Unknown
had to restart EUDAQ, no telepix now (can't reach GUI remotely)
303
Fri Oct 4 08:42:13 2024
tb-crew
VNFB scan
V W3-1E14
Backside
4.2
1.1
-500
30
Unknown
back with actual DAC scan
308
Fri Oct 4 09:31:31 2024
tb-crew
VNFB scan
V W3-1E14
Backside
4.2
1.1
-500
60
Unknown
we're missing telescope data from Run 269 -> 272
repeating these scans
311
Fri Oct 4 09:47:09 2024
tb-crew
VNFB scan
V W3-1E14
Backside
4.2
1.1
-500
10
Unknown
we we're running with too high of a bias voltage
we want -190V for these scans
starting all over again
318
Fri Oct 4 11:40:00 2024
tb-crew
L W3-3E14
Backside
4.2
Unknown
changed to next (LAST) DUT
319
Fri Oct 4 11:56:16 2024
tb-crew
std settings
L W3-3E14
Backside
4.2
1.1
-190
18
Unknown
we'll have to move the stage a bit, not very centered
321
Fri Oct 4 12:02:37 2024
tb-crew
centering DUT
L W3-3E14
Backside
4.2
Unknown
currently at
positionX = 54.5
positionY = 11
327
Fri Oct 4 12:28:37 2024
tb-crew
centering DUT
L W3-3E14
Backside
4.2
1.1
-190
Unknown
currently at
positionX = 56
positionY = 11.5
398
Sat Oct 5 09:26:25 2024
tb-crew
HV scan
L W3-3E14
Backside
4.2
0.95
-10
Unknown
telepix said ciao at run 362
399
Sat Oct 5 09:26:43 2024
tb-crew
L W3-3E14
Topside
4.2
0.95
-10
Unknown
Moving jumper
462
Sat Oct 5 23:32:15 2024
tb-crew
HV scan
V W8-0E0
Topside
4.2
Unknown
changed DUT
527
Sun Oct 6 10:06:40 2024
tb-crew
alignment
V W8-0E0
Topside
4.2
1.0
-280
Unknown
positionX = 55 # DUT measurement position
positionY = 11.5 # mm
528
Sun Oct 6 10:28:57 2024
tb-crew
V W8-0E0
Topside
4.2
1.0
-280
Unknown
full efficiency achived