  Belle/Infineon/AIDA testbeam at SPS in Nov 2014, Page 6 of 6  Not logged in ELOG logo
Entry  Thu Nov 20 00:55:14 2014, Hao Yin, Belle SVD, HardwareRun_007, , , , , Unknown 

temp cooled see attachment

last noise run(007)

FIRRun_002

PedestalRun_008

new cal run Raw, test with put fifo full flags

Entry  Thu Nov 20 10:22:17 2014, Markus Friedl, Belle SVD, common, , , , , Unknown 
  1. Some VME errors occured over night
  2. Optical fiber changed
  3. Situation improved

 

  1. L3n hybrid could not be configured by I2C
  2. Plugged cable into the former FWDn slot
  3. Fully working

 

Entry  Thu Nov 20 10:39:11 2014, Benedikt Würkner, Belle SVD, PedestalRun_009, , , , , Unknown 

cooled see appendix (FIRRun003)

MaxEvents 10000

 

Entry  Thu Nov 20 10:39:13 2014, Benedikt Würkner, Belle SVD, PedestalRun_009, , , , , Unknown 

cooled see appendix (FIRRun003)

MaxEvents 10000

 

Entry  Thu Nov 20 10:41:54 2014, Benedikt Würkner, Belle SVD, CalibrationRun_005, , , , , Unknown 

 cooled see appendix (FIRRun_003)

PedestalRun_009

Entry  Thu Nov 20 17:16:56 2014, Axel König, common, how to run the EUDAQ offline monitor, , , , , Unknown 

YOU need

1.) Folder EUDAQ OFFLINE Monitor

2.) ROOT

 

Starting: 

1.) open command line and chose the path where OfflineMonitor is

2.)Type -i "patch of raw file" -o test.root 100

3.) helpfile typing -h

Entry  Thu Nov 20 22:12:21 2014, Axel König, common, SPS Logbook / SPS Online Monitor, , , , , Unknown 

Logbook: https://ab-dep-op-elogbook.web.cern.ch/ab-dep-op-elogbook/elogbook/secure/eLogbook.php?shiftId=1059325

 

Monitor:  http://op-webtools.web.cern.ch/op-webtools/vistar/vistars.php?usr=SPS1

Entry  Fri Nov 21 18:23:05 2014, Axel König, common, New Table Calibration, , , , , Unknown 

 Nach powercut musste der Tisch neu kalibriert werden. Diese Neukalibration betrifft alle Messungen ab den ersten Messungen vom AIDA Stack.

Entry  Fri Nov 21 18:35:17 2014, Axel König, AIDA, Important: Dockbox Inverter!, , , , , Unknown 

Alle AIDA runs vor run_007 hatten kein Signal auf den Sensoren 5 und 6.

Grund: Inverter auf N Seite war im config file noch an (von Markus behoben). 

Runs vor 007 können noch verwendet werden obwohl sensoren 5 und 6 negative Events lieferten (kommt aber auf das negative Limit an). 

Entry  Fri Nov 21 19:05:27 2014, Hao Yin, Belle SVD, FIRRun_004, , , Fri Nov 21 19:05:23 CET 2014, , Unknown 

New ADC delay scan. cooled, -25 temperature

 

Entry  Fri Nov 21 19:10:09 2014, Hao Yin, Belle SVD, CalibrationRun_006, , , , , Unknown 

cooled, latest ADC delay scan and FIRRun. 

Entry  Fri Nov 21 19:42:36 2014, Hao Yin, , HardwareRun_033, , , , , Good Temp_21-11-14.PNG

L6 are swapped, needs to be corrected later in the offline analysis.

cooled at -25

latest ADC delay and FIRRun

PedestalRun_012

CalibrationRun_006

100k trigger dead time

 

Need to change L6n apv definition to:

mod = 9,0,1,1,1,m,29,0,0,0,0,0,0,L6_n_side

apv = 9,1,34,3,30,x,0,0,5,1,7,0,0,x
apv = 9,0,36,3,50,x,0,0,5,1,6,0,0,x
apv = 9,3,38,3,30,x,0,0,5,1,9,0,0,x
apv = 9,2,40,3,30,x,0,0,5,1,8,0,0,x

to  get the right mapping of the sensor.

Entry  Sat Nov 22 11:16:26 2014, Markus Friedl, Belle SVD, cooling, , , , , Unknown 

Cooling box plant hung up (I2C error on Alix, persistent after reboot)

Power-cycled cooling plant, now working

Slowly cooling down again

Entry  Sat Nov 22 16:43:18 2014, Axel König, common, table, telescope and dut geometry , , , , , Unknown geometry_table.pdfgeometry_DUT.pdfgeometry_infineon_batch4.pdfgeometry_infineon_old.pdf

geometry files

Entry  Sat Nov 22 19:29:40 2014, Axel König, AIDA, DUT Position, , , , , Unknown AIDA_DUT_Position.JPG
 
Entry  Sun Nov 23 09:49:00 2014, Markus Friedl, Belle SVD, cooling, , , , , Unknown temp_last_night.png

Saturday evening, the cooling became unstable which indicates the end of the CO2 supply, possibly having a mixture of liquid and gas phases.

Strange oscillations observed for the DUT temperatures until the MF valve was finally turned off close to midnight.

 

Entry  Sun Nov 23 12:39:45 2014, Axel König, common, PMT's of EUDET (Igor Rubinsky), , , , , Unknown 

Der zweite PM (entsprechend der Beamrichtung) war von Anfang an nicht angeschlossen an die TLU! Stattdessen war ein Atlas pixel sensor, welcher als 4ter PM fungiert angeschlossen. Genau dieser "PM" hatte 0 counts bei der TLU --> Igor sagt, dass dieser Sensor ("PM") anscheinend keine Versorgungsspannung hatte (~400V). Jetzt baut Igor diesen Atlas Sensor wieder aus und hat bereits den nicht angeschlossenen PM wieder angeschlossen an die TLU. DIeser PM zeigt aber nun zu viele counts. Deshalb behalten wir die AND mask 11 (auch jetzt bei den Belle Modulen).

Entry  Sun Nov 23 15:07:54 2014, Markus Friedl, Belle SVD, common, , , , , Unknown fwbw_setup.png

Geometry setup of FW/BW:

(all dimensions are in mm and refer to the sensor planes)