Thu Nov 20 00:55:14 2014, Hao Yin, Belle SVD, HardwareRun_007, , , , , Unknown
|
temp cooled see attachment
last noise run(007)
FIRRun_002
PedestalRun_008
new cal run Raw, test with put fifo full flags |
Thu Nov 20 10:22:17 2014, Markus Friedl, Belle SVD, common, , , , , Unknown
|
- Some VME errors occured over night
- Optical fiber changed
- Situation improved
- L3n hybrid could not be configured by I2C
- Plugged cable into the former FWDn slot
- Fully working
|
Thu Nov 20 10:39:11 2014, Benedikt Würkner, Belle SVD, PedestalRun_009, , , , , Unknown
|
cooled see appendix (FIRRun003)
MaxEvents 10000
|
Thu Nov 20 10:39:13 2014, Benedikt Würkner, Belle SVD, PedestalRun_009, , , , , Unknown
|
cooled see appendix (FIRRun003)
MaxEvents 10000
|
Thu Nov 20 10:41:54 2014, Benedikt Würkner, Belle SVD, CalibrationRun_005, , , , , Unknown
|
cooled see appendix (FIRRun_003)
PedestalRun_009 |
Thu Nov 20 17:16:56 2014, Axel König, common, how to run the EUDAQ offline monitor, , , , , Unknown
|
YOU need
1.) Folder EUDAQ OFFLINE Monitor
2.) ROOT
Starting:
1.) open command line and chose the path where OfflineMonitor is
2.)Type -i "patch of raw file" -o test.root 100
3.) helpfile typing -h |
Thu Nov 20 22:12:21 2014, Axel König, common, SPS Logbook / SPS Online Monitor, , , , , Unknown
|
Logbook: https://ab-dep-op-elogbook.web.cern.ch/ab-dep-op-elogbook/elogbook/secure/eLogbook.php?shiftId=1059325
Monitor: http://op-webtools.web.cern.ch/op-webtools/vistar/vistars.php?usr=SPS1 |
Fri Nov 21 18:23:05 2014, Axel König, common, New Table Calibration, , , , , Unknown
|
Nach powercut musste der Tisch neu kalibriert werden. Diese Neukalibration betrifft alle Messungen ab den ersten Messungen vom AIDA Stack. |
Fri Nov 21 18:35:17 2014, Axel König, AIDA, Important: Dockbox Inverter!, , , , , Unknown
|
Alle AIDA runs vor run_007 hatten kein Signal auf den Sensoren 5 und 6.
Grund: Inverter auf N Seite war im config file noch an (von Markus behoben).
Runs vor 007 können noch verwendet werden obwohl sensoren 5 und 6 negative Events lieferten (kommt aber auf das negative Limit an). |
Fri Nov 21 19:05:27 2014, Hao Yin, Belle SVD, FIRRun_004, , , Fri Nov 21 19:05:23 CET 2014, , Unknown
|
New ADC delay scan. cooled, -25 temperature
|
Fri Nov 21 19:10:09 2014, Hao Yin, Belle SVD, CalibrationRun_006, , , , , Unknown
|
cooled, latest ADC delay scan and FIRRun. |
Fri Nov 21 19:42:36 2014, Hao Yin, , HardwareRun_033, , , , , Good
|
L6 are swapped, needs to be corrected later in the offline analysis.
cooled at -25
latest ADC delay and FIRRun
PedestalRun_012
CalibrationRun_006
100k trigger dead time
Need to change L6n apv definition to:
mod = 9,0,1,1,1,m,29,0,0,0,0,0,0,L6_n_side
apv = 9,1,34,3,30,x,0,0,5,1,7,0,0,x
apv = 9,0,36,3,50,x,0,0,5,1,6,0,0,x
apv = 9,3,38,3,30,x,0,0,5,1,9,0,0,x
apv = 9,2,40,3,30,x,0,0,5,1,8,0,0,x
to get the right mapping of the sensor. |
Sat Nov 22 11:16:26 2014, Markus Friedl, Belle SVD, cooling, , , , , Unknown
|
Cooling box plant hung up (I2C error on Alix, persistent after reboot)
Power-cycled cooling plant, now working
Slowly cooling down again |
Sat Nov 22 16:43:18 2014, Axel König, common, table, telescope and dut geometry , , , , , Unknown
|
geometry files |
Sat Nov 22 19:29:40 2014, Axel König, AIDA, DUT Position, , , , , Unknown
|
|
Sun Nov 23 09:49:00 2014, Markus Friedl, Belle SVD, cooling, , , , , Unknown
|
Saturday evening, the cooling became unstable which indicates the end of the CO2 supply, possibly having a mixture of liquid and gas phases.
Strange oscillations observed for the DUT temperatures until the MF valve was finally turned off close to midnight.
|
Sun Nov 23 12:39:45 2014, Axel König, common, PMT's of EUDET (Igor Rubinsky), , , , , Unknown
|
Der zweite PM (entsprechend der Beamrichtung) war von Anfang an nicht angeschlossen an die TLU! Stattdessen war ein Atlas pixel sensor, welcher als 4ter PM fungiert angeschlossen. Genau dieser "PM" hatte 0 counts bei der TLU --> Igor sagt, dass dieser Sensor ("PM") anscheinend keine Versorgungsspannung hatte (~400V). Jetzt baut Igor diesen Atlas Sensor wieder aus und hat bereits den nicht angeschlossenen PM wieder angeschlossen an die TLU. DIeser PM zeigt aber nun zu viele counts. Deshalb behalten wir die AND mask 11 (auch jetzt bei den Belle Modulen). |
Sun Nov 23 15:07:54 2014, Markus Friedl, Belle SVD, common, , , , , Unknown
|
Geometry setup of FW/BW: