101
|
Sun Nov 23 00:20:41 2014 |
Axel König | Infineon | hardware run | Infineon_old_run003 | 30000 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.9797uA
(new table calibration): V:?, H:?
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000994
DaqEvents: 30000 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
102
|
Sun Nov 23 00:24:15 2014 |
Axel König | Infineon | hardware run | Infineon_old_run004 | 168725 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.6529uA
(new table calibration): V:81, H:88
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000996
DaqEvents: 168725 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
103
|
Sun Nov 23 00:51:07 2014 |
Axel König | Infineon | hardware run | Infineon_old_run005 | 26569 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.4609uA
(new table calibration): V:75, H:94.5
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000997
DaqEvents: 26569 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset)
|
|
107
|
Sun Nov 23 09:32:48 2014 |
Axel König | Infineon | hardware run | Infineon_old_run007 | 63913 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.4028uA
(new table calibration): V:75, H:96.5
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000999
DaqEvents: 63913 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
108
|
Sun Nov 23 09:36:27 2014 |
Axel König | Infineon | hardware run | Infineon_old_run006 | 526562 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.4028uA
(new table calibration): V:75, H:95
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000998
DaqEvents: 526562 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
1
|
Fri Nov 14 19:01:27 2014 |
Thomas Bergauer | common | Administrative Procedures for Departure | | | | | Unknown |
Wednesday:
* Transport request starten (I do not need any transport service) von 887 nach Wien. Das triggert automatisch die Radio Protection Leute. Der EDH Request hängt dann bei irgend einem Franzosen. Den bitte anrufen und für Montag mittags einen Termin ausmachen. Es muss alles geschnüffelt werden, was in der Zone war (also nicht im Counting room)
Merchandise-Bestätigung für die Anreise ist im attachment!
Anreise: https://edh.cern.ch/Document/SupplyChain/SHIP/5855845
Abreise: https://edh.cern.ch/Document/SupplyChain/SHIP/5863835
|
Attachment 1: Merchandise-2014.pdf
|
Attachment 2: ankunftsbestaetigung.pdf
|
2
|
Fri Nov 14 19:22:40 2014 |
Martin Kurz | common | ip addresses, portforwarding, wlan | | | | | Unknown |
WLAN Router:
SSID: Hephy
password: 20supersecret14
DHCP Range: 192.168.0.200 to 239
Netmask: /24
DNS Server: 192.168.0.254
Gateway: 192.168.0.254
external IP: 128.141.61.16 (für diverse Port Forwardings)
Manuell vergebene IP Adressen bitte unbedingt Martin Kurz mitteilen oder/und in der folgenden Tabelle eintragen!
IP/MAC Zuweisung:
IP |
Machine/Name |
intern |
Port Forwarding (aussen) |
192.168.0.10 |
SVD Kenwood |
VNC(5900) |
VNC(9000) |
192.168.0.11 |
AIDA DAQ |
VNC(5900) |
VNC(9001) |
192.168.0.12 |
TUX DAQ |
VNC(5900), VNC(5901), SSH(22) |
VNC(9009), VNC(9002), SSH(9003), |
192.168.0.13 |
Belle XY Tisch |
|
|
192.168.0.14 |
TUXOA |
SSH(22) |
SSH(9004) |
192.168.0.15 |
JTAG Server |
|
|
192.168.0.148 |
alixcool |
|
|
192.168.0.16 |
slowcontrol |
VNC(5900) |
VNC(9005) |
192.168.0.144 |
CAEN Power supply |
|
|
192.168.0.17 |
zenpixelwiki |
SSH(22), VNC(5900) |
SSH(9006), VNC(9008) |
192.168.0.18 |
TLU (pcx25042, XY) |
VNC(5900) |
VNC(9007) |
192.168.0.240 |
NI GPIB - ENET / 1000 |
|
|
192.168.0.150 |
Printserver |
VNC(5900) |
VNC(9010) |
|
|
|
|
|
|
|
|
Admin Zugang Wlan Router:
IP: 192.168.0.254
Username: admin
password: Hephy2014
|
4
|
Fri Nov 14 19:49:04 2014 |
Florian Buchsteiner | common | Belle Setup | | | | | Unknown |
|
Attachment 1: SPS_2014_Testbeam_-_Belle_Setup-Model.pdf
|
6
|
Sat Nov 15 11:36:41 2014 |
Thomas Bergauer | common | Checklist for North Area access | | | | | Unknown |
Checklist for North Area access:
- Dosimeter (http://dosimetry.web.cern.ch/en
)
- Helmet and safety shoes (http://gs-dep.web.cern.ch/en/content/stores_hours
)
- Access right to H6A control room (request via EDH): Control Room HNA-447 (0887-1-Q45). Activate access right on your CERN access card at one of the validation stations (https://espace.cern.ch/service-access-control/default.aspx
)
- For using CERN rental car, request "CERN vehicle driving license (V)" via EDH
- Park in front of bldg. 890. Walk to North Hall (bldg. 887) through bldg. 907. Swipe dosimeter in front of electronic lock next to the entrance door. Turn left inside bldg. 887. Control room Q45 is on the left-hand side of the upper level. Swipe CERN access card in front of electronic lock.
|
10
|
Sun Nov 16 21:37:56 2014 |
Hao Yin | common | AIM | | | | | Unknown |
fachi: aimhephy@antispam.e4ward.com
chrisu: gargamel0971
flo: flo.bux@sbg.at
shorty: martin@kurznet.net
markus; mueffi1040
hao: hao.yin@gmx.at
benni: benedikt.wuerkner@assoc.oeaw.ac.at
juan: juan.garcia.ferrero@cern.ch
axel: ???
bergi: callmebergi |
12
|
Mon Nov 17 22:03:02 2014 |
Martin Kurz | common | Drucker | | | | | Unknown |
Drucken über den Printserver (192.168.0.150):
MAC:
direkt über den universellen AirPrint Treiber oder mittels Treiber vom Gerätehersteller drucken.
Einfach nach Druckern suchen. Druckername: CanonMP630 @ higgscms
LINUX:
Eine Datei Names (/etc/cups/client.conf) mit dem Inhalt folgenden Inhalt -ohne Anführungszeichen- erstellen: "ServerName 192.168.0.150"
--> sofort steht der Drucker mit allen richtigen Einstellungen zur Verfügung
Drucken mittels Treiber vom Gerätehersteller ist weiterhin möglich. (wird von CUPS automatisch zur Verfügung gestellt) CUPS URL: "http://192.168.0.150:631/printers/CanonMP630"
WINDOWS:
1.) Unter Start->Einstellungen->Drucker und Faxgeräte links den Punkt “neuen Drucker hinzufügen” auswählen.
2.) In dem sich öffnenden Assistenten die Option “Netzwerkdrucker hinzufügen” auswählen und auf “weiter” klicken.
3.) Zunächst den Punkt “Verbindung mit einem Drucker im Internet herstellen” auswählen und dann die "URL" zum Drucker einfügen.
Name: http://192.168.0.150:631/printers/CanonMP630
|
28
|
Tue Nov 18 12:35:32 2014 |
Axel König | common | Infineon (4 modules) TLU Settings | | | | | Unknown |
- VNC to 192.168.0.18
- In command line: cd C:\Users\telescope\eudaq\bin
- TLUControl.exe.exe -d 2 -a 11 - i RJ45
Operating with AIDA telescope: TLUControl.exe.exe -d 3 -a 11 - i RJ45
Dut Position (left to right): 11, 06, 05, 07 |
39
|
Wed Nov 19 16:24:25 2014 |
Axel König | common | Running EUDAQ | | | | | Unknown |
Windows PC at Telescope:
0.) JTAG Programming: Chose a threshold file (recommended threshold 5) File: M26TB_Cern_2011.thresh5.mcf--> press start
1.) C:\Users\telescope\Desktop\users\BelleII --> start Mimosa 26 Telescope --> select all six Mimosa's
2.) C:\Users\telescope\Desktop\users\BelleII --> start startEudaq_fullWindows.bat
3.) Use configuration file hephy1 (location: C:\eudaq\conf). Change it according to your TLU settings (DUT mask, AND mask, etc.)
4.) configure
5.) start
x) Online monitor in preparation
Files: Are saved in C:\eudaq\data with internal numbering "run000000xxx.raw" (look at the date and time). [You can connect locally to this folder at HEPHY-SVD PC] |
64
|
Thu Nov 20 17:16:56 2014 |
Axel König | common | how to run the EUDAQ offline monitor | | | | | Unknown |
YOU need
1.) Folder EUDAQ OFFLINE Monitor
2.) ROOT
Starting:
1.) open command line and chose the path where OfflineMonitor is
2.)Type -i "patch of raw file" -o test.root 100
3.) helpfile typing -h |
67
|
Thu Nov 20 22:12:21 2014 |
Axel König | common | SPS Logbook / SPS Online Monitor | | | | | Unknown |
Logbook: https://ab-dep-op-elogbook.web.cern.ch/ab-dep-op-elogbook/elogbook/secure/eLogbook.php?shiftId=1059325
Monitor: http://op-webtools.web.cern.ch/op-webtools/vistar/vistars.php?usr=SPS1 |
78
|
Fri Nov 21 18:23:05 2014 |
Axel König | common | New Table Calibration | | | | | Unknown |
Nach powercut musste der Tisch neu kalibriert werden. Diese Neukalibration betrifft alle Messungen ab den ersten Messungen vom AIDA Stack. |
96
|
Sat Nov 22 16:43:18 2014 |
Axel König | common | table, telescope and dut geometry | | | | | Unknown |
geometry files |
Attachment 1: geometry_table.pdf
|
Attachment 2: geometry_DUT.pdf
|
Attachment 3: geometry_infineon_batch4.pdf
|
Attachment 4: geometry_infineon_old.pdf
|
113
|
Sun Nov 23 12:39:45 2014 |
Axel König | common | PMT's of EUDET (Igor Rubinsky) | | | | | Unknown |
Der zweite PM (entsprechend der Beamrichtung) war von Anfang an nicht angeschlossen an die TLU! Stattdessen war ein Atlas pixel sensor, welcher als 4ter PM fungiert angeschlossen. Genau dieser "PM" hatte 0 counts bei der TLU --> Igor sagt, dass dieser Sensor ("PM") anscheinend keine Versorgungsspannung hatte (~400V). Jetzt baut Igor diesen Atlas Sensor wieder aus und hat bereits den nicht angeschlossenen PM wieder angeschlossen an die TLU. DIeser PM zeigt aber nun zu viele counts. Deshalb behalten wir die AND mask 11 (auch jetzt bei den Belle Modulen). |