Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle/Infineon/AIDA testbeam at SPS in Nov 2014, Page 5 of 6  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Project Subjectdown Run Number Events StartTime EndTime Data
  73   Fri Nov 21 15:07:24 2014 Benedikt WürknerBelle SVDHardwareRun0191509482014-11-21 02:41:552014-11-21 10:11:02Unknown

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)

VME Error, overnight run

  74   Fri Nov 21 15:10:19 2014 Benedikt Würkner HardwareRun15-22 (exept 19) none  Crap
  93   Sat Nov 22 11:37:16 2014 Benedikt WürknerBelle SVDHardwareRun0364503782014-11-22 1:00:002014-11-22 10:27:54Unknown

 Not completely cooled since cooling failed at 1:42 in the night

Bias voltage set to +-60V

Some error with event no17 or 18 leading to the data not being easily analysable requiring a hack in TuxOA

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

Attachment 1: SPS_Testbeam-Temp.xlsx
Attachment 2: Screen_Shot_2014-11-22_at_12.41.44.png
Screen_Shot_2014-11-22_at_12.41.44.png
  94   Sat Nov 22 15:31:49 2014 Hao YinBelle SVDHardwareRun038437882014-11-22 15:18:40 Unknown

Cooled down to -20

Bias voltage set to +-60V

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

Zero suppressed

  105   Sun Nov 23 01:05:43 2014 Hao YinBelle SVDHardwareRun039200002014-11-22 15:18:40 Crap

Cooled down to -20

Bias voltage set to +-80V

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

 

  106   Sun Nov 23 01:37:42 2014 Hao YinBelle SVDHardwareRun040200002014-11-23 01:37:00 Unknown

Bias voltage set to +-80V

Pedestal_015 (cooled)

"New" layout with no cooling (CO2 is no more)

Newly set values for APC Delay

New FIR Run 005

Temperature around 30 C

Bias: +-80V

  111   Sun Nov 23 10:51:49 2014 Hao YinBelle SVDHardwareRun04276863  Unknown

Hardware Run +-40V Bias

Room Temperature

Pedestal 016

Zero Suppressed

Attachment 1: Temp_23-11-14.PNG
Temp_23-11-14.PNG
  112   Sun Nov 23 12:17:59 2014 Benedikt WürknerBelle SVDHardwareRun04420000  Unknown

Hardware Run +-30V Bias

Room Temperature

Pedestal 017 (again marked all the bad strips)

Zero Suppressed

  114   Sun Nov 23 12:55:47 2014 Benedikt WürknerBelle SVDHardwareRun04520000  Unknown

Hardware Run +-50V Bias

Room Temperature

Pedestal 018 (again marked all the bad strips)

Zero Suppressed

  118   Sun Nov 23 15:13:37 2014 Markus FriedlBelle SVDHardwareRun00310060023.11.2014 14:07:2323.11.2014 16:51:27Good

Hardware run, hitting APVs 0/1 on p-sides, 1/2 on n-sides

EUDAT telescope running with difference of 2 events

  119   Sun Nov 23 16:55:37 2014 Markus FriedlBelle SVDHardwareRun0046060023.11.2014 16:51:4923.11.2014 18:23:54Good

Hardware run, hitting APVs 1/2 on p-sides, 1/2 on n-sides

EUDAT telescope running with difference of 2 events

Entry is currently edited by Thomas Bergauer on 193.170.243.91    120   Sun Nov 23 17:51:44 2014 Benedikt WürknerBelle SVDHardwareRun04610000020:0620:36Unknown

Hardware Run +-60V Bias

Room Temperature

Pedestal 018 (again marked all the bad strips)

Zero Suppressed

 

  121   Sun Nov 23 18:26:54 2014 Markus FriedlBelle SVDHardwareRun0056060023.11.2014 18:24:3423.11.2014 Good

Hardware run, hitting APVs 2/3 on p-sides, 1/2 on n-sides

EUDAT telescope running with difference of 2 events

  80   Fri Nov 21 19:05:27 2014 Hao YinBelle SVDFIRRun_004  Fri Nov 21 19:05:23 CET 2014 Unknown

New ADC delay scan. cooled, -25 temperature

 

  23   Tue Nov 18 09:45:59 2014 Hao Yin FIRRun_002002 Tue Nov 18 09:45:58 CET 2014 Unknown

New FIR run after reconecting to original setting. 

  50   Thu Nov 20 00:52:50 2014 Hao YinBelle SVDFIRRun_002    Unknown

cooled with new delay run

  54   Thu Nov 20 10:33:13 2014 Benedikt WürknerBelle SVDFIRRun and Delay Scan003   Unknown

 Cooled see appendix

with new layout (l3_n-side channels changed and reactivated).

Latest FIRRun

Attachment 1: Temp_19-11-14.PNG
Temp_19-11-14.PNG
  14   Mon Nov 17 22:21:41 2014 Hao Yin FIR run001 Mon Nov 17 22:08:29 CET 2014 Good

Excellent, brilliant run. 

  12   Mon Nov 17 22:03:02 2014 Martin KurzcommonDrucker    Unknown

Drucken über den Printserver (192.168.0.150):

 

MAC:

direkt über den universellen AirPrint Treiber oder mittels Treiber vom Gerätehersteller drucken.

Einfach nach Druckern suchen. Druckername: CanonMP630 @ higgscms


LINUX:

Eine Datei Names (/etc/cups/client.conf) mit dem Inhalt folgenden Inhalt -ohne Anführungszeichen- erstellen: "ServerName 192.168.0.150"

--> sofort steht der Drucker mit allen richtigen Einstellungen zur Verfügung

Drucken mittels Treiber vom Gerätehersteller ist weiterhin möglich. (wird von CUPS automatisch zur Verfügung gestellt) CUPS URL: "http://192.168.0.150:631/printers/CanonMP630"

 

WINDOWS:

1.) Unter Start->Einstellungen->Drucker und Faxgeräte links den Punkt “neuen Drucker hinzufügen” auswählen.

2.) In dem sich öffnenden Assistenten die Option “Netzwerkdrucker hinzufügen” auswählen und auf “weiter” klicken.

3.) Zunächst den Punkt “Verbindung mit einem Drucker im Internet herstellen” auswählen und dann die "URL" zum Drucker einfügen.

Name: http://192.168.0.150:631/printers/CanonMP630

 

 

  8   Sat Nov 15 12:41:50 2014 Benedikt WürknerBelle SVDDiscoveries during preliminary sensor tests    Unknown

L5_p_side APV #3 faulty signal

L4_n_side APV #2 and #3 faulty signal

Attachment 1: weird_signal.png
weird_signal.png
Attachment 2: faulty-signal-l4_n.png
faulty-signal-l4_n.png
Attachment 3: faulty-signal_l4_n_2.png
faulty-signal_l4_n_2.png
ELOG V3.1.5-fc6679b