Entry  Fri Nov 21 15:10:19 2014, Benedikt Würkner, , HardwareRun, 15-22 (exept 19) , none, , , Crap 
 
Entry  Fri Nov 21 15:37:30 2014, Axel König, AIDA, hardware run, AIDA_run004, 7057, , , Unknown 

AIDA

 

single hit

Voltage=100V, I=5.4357uA

(new table calibration): V:71mm, H:80mm

 

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000977

--Stopped 21.11 / 12:12--

DaqEvents: 7057 (-600 ped)

EUDAQ EVENTS: 4658 (less than Daq) 

Entry  Fri Nov 21 18:20:47 2014, Axel König, AIDA, hardware run, AIDA_run005, 20045, , , Unknown 

AIDA

single hit

Voltage=100V, I=5.4357uA

(new table calibration): V:71mm, H:80mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000979

--Stopped 21.11 / 12:12--

DaqEvents: 20045 (-600 ped)

EUDAQ EVENTS: ~18k

Entry  Fri Nov 21 18:21:45 2014, Axel König, AIDA, hardware run, AIDA_run006, ~1k, , , Unknown 

 verwerfen!

Entry  Fri Nov 21 18:23:05 2014, Axel König, common, New Table Calibration, , , , , Unknown 

 Nach powercut musste der Tisch neu kalibriert werden. Diese Neukalibration betrifft alle Messungen ab den ersten Messungen vom AIDA Stack.

Entry  Fri Nov 21 18:35:17 2014, Axel König, AIDA, Important: Dockbox Inverter!, , , , , Unknown 

Alle AIDA runs vor run_007 hatten kein Signal auf den Sensoren 5 und 6.

Grund: Inverter auf N Seite war im config file noch an (von Markus behoben). 

Runs vor 007 können noch verwendet werden obwohl sensoren 5 und 6 negative Events lieferten (kommt aber auf das negative Limit an). 

Entry  Fri Nov 21 19:10:09 2014, Hao Yin, Belle SVD, CalibrationRun_006, , , , , Unknown 

cooled, latest ADC delay scan and FIRRun. 

Entry  Fri Nov 21 19:25:57 2014, Axel König, AIDA, hardware run, AIDA_run007, 26770, , , Unknown 

AIDA

multi hit

Voltage=100V, I=5.4357uA

(new table calibration): V:71mm, H:65mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000983

--Stopped 21.11 / 19:20--

DaqEvents: 26770 (-600 ped)

EUDAQ EVENTS: 26171 (+1 trigger offset)

Entry  Fri Nov 21 19:42:36 2014, Hao Yin, , HardwareRun_033, , , , , Good Temp_21-11-14.PNG

L6 are swapped, needs to be corrected later in the offline analysis.

cooled at -25

latest ADC delay and FIRRun

PedestalRun_012

CalibrationRun_006

100k trigger dead time

 

Need to change L6n apv definition to:

mod = 9,0,1,1,1,m,29,0,0,0,0,0,0,L6_n_side

apv = 9,1,34,3,30,x,0,0,5,1,7,0,0,x
apv = 9,0,36,3,50,x,0,0,5,1,6,0,0,x
apv = 9,3,38,3,30,x,0,0,5,1,9,0,0,x
apv = 9,2,40,3,30,x,0,0,5,1,8,0,0,x

to  get the right mapping of the sensor.

Entry  Fri Nov 21 22:08:32 2014, Hao Yin, , PedestalRun, 013, 10000, , , Unknown 

correct mapping

cooled -25 °C

L3n deactivated

 

Entry  Fri Nov 21 23:33:54 2014, Axel König, AIDA, hardware run (PC crashed), AIDA_run008, ---, , , Unknown 

22:00 SVD3 PC crashed!!! data will be collected. 

Entry  Fri Nov 21 23:34:36 2014, Axel König, AIDA, hardware run, AIDA_run009, 32902, , , Unknown 

 

AIDA

multi hit

Voltage=100V, I=5.2190uA

(new table calibration): V:71mm, H:100mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000983

--Stopped 21.11 / 19:20--

DaqEvents: 32902 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

 
Entry  Fri Nov 21 23:40:10 2014, Axel König, AIDA, hardware run, AIDA_run010, 26329, , , Unknown 

  

AIDA

multi hit

Voltage=100V, I=5.3470uA

(new table calibration): V:71mm, H:90mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000987

DaqEvents: 26329 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

 
Entry  Sat Nov 22 00:11:36 2014, Axel König, AIDA, hardware run, AIDA_run011, 24916, , , Unknown 

AIDA

multi hit

Voltage=100V, I=5.3470uA

(new table calibration): V:71mm, H:80mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000988

DaqEvents: 24916 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

Entry  Sat Nov 22 00:58:04 2014, Axel König, AIDA, hardware run, AIDA_run012, 276006, , , Unknown 

AIDA

multi hit

Voltage=100V, I=5.3417uA

(new table calibration): V:51mm, H:70mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000989

DaqEvents: 276006 (-600 ped)

EUDAQ EVENTS: 275390 

Entry  Sat Nov 22 07:56:33 2014, Axel König, AIDA, hardware run, AIDA_run013, 55629, , , Unknown 

AIDA

multi hit

Voltage=100V, I=5.3417uA

(new table calibration): V:51mm, H:45mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000990

DaqEvents: 55629 (-600 ped)

EUDAQ EVENTS: 55003 

 
Entry  Sat Nov 22 10:20:07 2014, Axel König, AIDA, calibration run, AIDA_calibration, , , , Unknown 

Calibration run AIDA_calibration 

L:\cern14\AIDA

Entry  Sat Nov 22 11:16:26 2014, Markus Friedl, Belle SVD, cooling, , , , , Unknown 

Cooling box plant hung up (I2C error on Alix, persistent after reboot)

Power-cycled cooling plant, now working

Slowly cooling down again

Entry  Sat Nov 22 16:04:05 2014, Axel König, Infineon, Infineon old calibration, Infineon_old_calibration, , , , Unknown 

Calibration run 

L:\cern14\infineon_old

Entry  Sat Nov 22 16:43:18 2014, Axel König, common, table, telescope and dut geometry , , , , , Unknown geometry_table.pdfgeometry_DUT.pdfgeometry_infineon_batch4.pdfgeometry_infineon_old.pdf