Entry  Sat Nov 22 11:16:26 2014, Markus Friedl, Belle SVD, cooling, , , , , Unknown 
Cooling box plant hung up (I2C error on Alix, persistent after reboot)
Power-cycled cooling plant, now working
Slowly cooling down again
Entry  Sat Nov 22 11:37:16 2014, Benedikt Würkner, Belle SVD, HardwareRun, 036, 450378, 2014-11-22 1:00:00, 2014-11-22 10:27:54, Unknown SPS_Testbeam-Temp.xlsxScreen_Shot_2014-11-22_at_12.41.44.png
 Not completely cooled since cooling failed at 1:42 in the night
Bias voltage set to +-60V
Some error with event no17 or 18 leading to the data not being easily analysable requiring a hack in TuxOA
Entry  Sat Nov 22 15:31:49 2014, Hao Yin, Belle SVD, HardwareRun, 038, 43788, 2014-11-22 15:18:40, , Unknown 
Cooled down to -20
Bias voltage set to +-60V
Pedestal_013 (cooled)
Entry  Sat Nov 22 16:04:05 2014, Axel König, Infineon, Infineon old calibration, Infineon_old_calibration, , , , Unknown 
Calibration run 
L:\cern14\infineon_old
Entry  Sat Nov 22 16:43:18 2014, Axel König, common, table, telescope and dut geometry , , , , , Unknown geometry_table.pdfgeometry_DUT.pdfgeometry_infineon_batch4.pdfgeometry_infineon_old.pdf
geometry files
Entry  Sat Nov 22 16:53:39 2014, Axel König, Infineon, Infineon old, Infineon_old_run001, 55000 , , , Unknown 
Infineon old
multi hit
Voltage=300V, I=10.9797uA
Entry  Sat Nov 22 17:00:43 2014, Axel König, Infineon, Infineon old, damaged strixel sensors, strange IV behaviour, , , , Unknown 
1.) No events recorded for strixel sensors (run001). They seem to be damaged like they were at DESY.
2.) Very strange IV behaviour for every old Infineon module (especially TB12_baby1). 
Entry  Sat Nov 22 18:08:03 2014, Axel König, Infineon, hardware run, Infineon_old_run002, 55000, , , Unknown 
Infineon old
multi hit
Voltage=300V, I=10.9797uA
Entry  Sat Nov 22 19:29:40 2014, Axel König, AIDA, DUT Position, , , , , Unknown AIDA_DUT_Position.JPG
 
Entry  Sun Nov 23 00:20:41 2014, Axel König, Infineon, hardware run, Infineon_old_run003, 30000, , , Unknown 
Infineon old
multi hit
Voltage=300V, I=10.9797uA
Entry  Sun Nov 23 00:24:15 2014, Axel König, Infineon, hardware run, Infineon_old_run004, 168725, , , Unknown 
Infineon old
multi hit
Voltage=300V, I=10.6529uA
Entry  Sun Nov 23 00:51:07 2014, Axel König, Infineon, hardware run, Infineon_old_run005, 26569, , , Unknown 

    
      
 
            
            
Entry  Sun Nov 23 01:37:42 2014, Hao Yin, Belle SVD, HardwareRun, 040, 20000, 2014-11-23 01:37:00, , Unknown 
Bias voltage set to +-80V
Pedestal_015 (cooled) 

p, li { white-space: pre-wrap; }
"New" layout with no cooling (CO2 is no more)
Entry  Sun Nov 23 09:32:48 2014, Axel König, Infineon, hardware run, Infineon_old_run007, 63913, , , Unknown 
Infineon old
multi hit
Voltage=300V, I=10.4028uA
Entry  Sun Nov 23 09:36:27 2014, Axel König, Infineon, hardware run, Infineon_old_run006, 526562, , , Unknown 
Infineon old
multi hit
Voltage=300V, I=10.4028uA
Entry  Sun Nov 23 09:49:00 2014, Markus Friedl, Belle SVD, cooling, , , , , Unknown temp_last_night.png
Saturday evening, the cooling became unstable which indicates the end of the CO2 supply, possibly having a mixture of liquid and gas phases.
Strange oscillations observed for the DUT temperatures until the MF valve was finally turned off close to midnight.
 
Entry  Sun Nov 23 10:32:41 2014, Hao Yin, Belle SVD, PedestalRun, 016, 10000, , , Unknown 
Pedestal Run 
room temperature (30C)
Bias scans planned
Entry  Sun Nov 23 10:51:49 2014, Hao Yin, Belle SVD, HardwareRun, 042, 76863, , , Unknown Temp_23-11-14.PNG
Hardware Run +-40V Bias
Room Temperature
Pedestal 016
Entry  Sun Nov 23 12:17:59 2014, Benedikt Würkner, Belle SVD, HardwareRun, 044, 20000, , , Unknown 
Hardware Run +-30V Bias
Room Temperature
Pedestal 017 (again marked all the bad strips)
Entry  Sun Nov 23 12:39:45 2014, Axel König, common, PMT's of EUDET (Igor Rubinsky), , , , , Unknown 
Der zweite PM (entsprechend der Beamrichtung) war von Anfang an nicht angeschlossen an die TLU! Stattdessen war ein Atlas pixel sensor, welcher
als 4ter PM fungiert angeschlossen. Genau dieser "PM" hatte 0 counts bei der TLU --> Igor sagt, dass dieser Sensor ("PM") anscheinend
keine Versorgungsspannung hatte (~400V). Jetzt baut Igor diesen Atlas Sensor wieder aus und hat bereits den nicht angeschlossenen PM wieder angeschlossen