68
|
Fri Nov 21 01:43:54 2014 |
Axel König | AIDA | calibration run | AIDA_run001_calibration | | | | Unknown |
Calibration run with AIDA DUT.
Single hit |
91
|
Sat Nov 22 10:20:07 2014 |
Axel König | AIDA | calibration run | AIDA_calibration | | | | Unknown |
Calibration run AIDA_calibration
L:\cern14\AIDA |
53
|
Thu Nov 20 10:22:17 2014 |
Markus Friedl | Belle SVD | common | | | | | Unknown |
- Some VME errors occured over night
- Optical fiber changed
- Situation improved
- L3n hybrid could not be configured by I2C
- Plugged cable into the former FWDn slot
- Fully working
|
115
|
Sun Nov 23 15:07:54 2014 |
Markus Friedl | Belle SVD | common | | | | | Unknown |
Geometry setup of FW/BW:
(all dimensions are in mm and refer to the sensor planes) |
92
|
Sat Nov 22 11:16:26 2014 |
Markus Friedl | Belle SVD | cooling | | | | | Unknown |
Cooling box plant hung up (I2C error on Alix, persistent after reboot)
Power-cycled cooling plant, now working
Slowly cooling down again |
109
|
Sun Nov 23 09:49:00 2014 |
Markus Friedl | Belle SVD | cooling | | | | | Unknown |
Saturday evening, the cooling became unstable which indicates the end of the CO2 supply, possibly having a mixture of liquid and gas phases.
Strange oscillations observed for the DUT temperatures until the MF valve was finally turned off close to midnight.
|
29
|
Tue Nov 18 13:13:53 2014 |
Thomas Bergauer | Infineon | hardware run | infineon_run001 | 225508 | | | Unknown |
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.2475 µA
strips horizontal
data file in L:\cern14\infineon\Infineon Run horiz
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
STOPPED by main User in H6B (18:11, 15:00)
Events: 225508
Next step: rearange modules vertically
|
31
|
Tue Nov 18 18:33:31 2014 |
Axel König | Infineon | hardware run | Infineon_run003 | 300000 | | | Unknown |
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0044 µA
strips vertical
Table Position: H: 96mm V: 101mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--Stopped 18.11 / 20:20---
Reason: Enough events, adjusting new DUT position for next run
Events: 300000 |
36
|
Tue Nov 18 23:04:34 2014 |
Axel König | Infineon | hardware run | Infineon_run004 | 400000 | | | Unknown |
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0044 µA
strips vertical
Table Position: H: 96mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--stopped 18.11 // 23:05---
Reason: Enough events, next run with the same position but now multi six
Events: 400000
|
37
|
Wed Nov 19 00:58:27 2014 |
Axel König | Infineon | hardware run | Infineon_run005 | 87000 | | | Unknown |
Infineon new stack - batch 4
multi hit
HV=300V, total I = 4.0200 µA
strips vertical
Table Position: H: 96mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
--stopped 19.11 // 01:00 --
Reason: Enough events, new dut postion for next multi run
Events: 87000 |
38
|
Wed Nov 19 09:26:39 2014 |
Axel König | Infineon | hardware run | Infineon_run006 | 1500 | | | Unknown |
Infineon new stack - batch 4
multi hit
HV=300V, total I = 4.0200 µA
strips vertical
Table Position: H: 96mm V: 91mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
-- stopped --
1500 Events only --> no trigger signals from TU (01:30 Uhr) |
44
|
Wed Nov 19 21:56:44 2014 |
Axel König | Infineon | hardware run | Infineon_run008 | 244167 | | | Unknown |
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0758 µA
strips vertical
Table Position: H: 92.5mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--stopped 19.11 // 21:53 --
Reason: Want to run the eudaq for the next run
Events: 244167 |
45
|
Wed Nov 19 22:15:41 2014 |
Axel König | Infineon | hardware run | Infineon_run010 | 1498709 | | | Unknown |
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0200 µA
strips vertical
Table Position: H: 92.5mm V: 81mm
EUDAQ data: Run951 and Run952
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
-- stopped 20.11 / 09:35--
SVD3DAQ Events: 1498709
EUDAQ Events: 2777
EUDAQ stopped counting events --> log entry: "01:38 6-ERROR unexpected trigger number 277714 (expecting 277713)" (TLU Producer) |
61
|
Thu Nov 20 15:46:21 2014 |
Axel König | Infineon | hardware run | Infineon_run012 | 263470 | | | Unknown |
Infineon new stack - batch 4
single hit
HV=300V, total I = ? µA
strips vertical
Table Position: H: 89mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--stopped 20.11 // 15:30 --
Eudaq: No Events build --> searching for failure
Events: 263470 |
62
|
Thu Nov 20 15:47:56 2014 |
Axel König | Infineon | hardware run | Infineon_run011 | | | | Unknown |
Infineon new stack - batch 4
faulty!!! |
65
|
Thu Nov 20 18:15:48 2014 |
Axel König | Infineon | hardware run | Infineon_run013_voltage | 51273 | | | Unknown |
Infineon new stack - batch 4
single hit + eudaq
HV=100V, total I = 3.0326 µA
strips vertical
Table Position: H: 89mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
eudaq file: run000959.raw
--stopped 20.11 // 18:10 --
Eudaq: 54928
Events: 51273 |
69
|
Fri Nov 21 11:10:08 2014 |
Axel König | AIDA | hardware run | AIDA_run002 | 211362 | | | Unknown |
AIDA
multi hit
Voltage=100V, I=4.1688uA
(new table calibration): V:56mm, H:96mm
EUDAQ File: Run000962, Run000963, Run000964
config: L:\cern14\AIDA
data: L:\cern14\AIDA
--Stopped 21.11 / 10:30--
DaqEvents: 211362
EUDAQ EVENTS: ca. 41000 |
70
|
Fri Nov 21 12:14:46 2014 |
Axel König | AIDA | hardware run | AIDA_run003 | 20617 | | | Unknown |
AIDA
single hit
Voltage=100V, I=5.4240uA
(new table calibration): V:66mm, H:74mm
EUDAQ file: Run000965
config: L:\cern14\AIDA
data: L:\cern14\AIDA
--Stopped 21.11 / 12:12--
DaqEvents: 20617 (-600 ped)
EUDAQ EVENTS: 20019 (2 more than DAQ [+2 offset]) |
75
|
Fri Nov 21 15:37:30 2014 |
Axel König | AIDA | hardware run | AIDA_run004 | 7057 | | | Unknown |
AIDA
single hit
Voltage=100V, I=5.4357uA
(new table calibration): V:71mm, H:80mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: Run000977
--Stopped 21.11 / 12:12--
DaqEvents: 7057 (-600 ped)
EUDAQ EVENTS: 4658 (less than Daq) |
76
|
Fri Nov 21 18:20:47 2014 |
Axel König | AIDA | hardware run | AIDA_run005 | 20045 | | | Unknown |
AIDA
single hit
Voltage=100V, I=5.4357uA
(new table calibration): V:71mm, H:80mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: Run000979
--Stopped 21.11 / 12:12--
DaqEvents: 20045 (-600 ped)
EUDAQ EVENTS: ~18k |