Entry  Sat Nov 22 16:04:05 2014, Axel König, Infineon, Infineon old calibration, Infineon_old_calibration, , , , Unknown 
Calibration run 
L:\cern14\infineon_old
Entry  Sat Nov 22 16:43:18 2014, Axel König, common, table, telescope and dut geometry , , , , , Unknown geometry_table.pdfgeometry_DUT.pdfgeometry_infineon_batch4.pdfgeometry_infineon_old.pdf
geometry files
Entry  Sat Nov 22 17:00:43 2014, Axel König, Infineon, Infineon old, damaged strixel sensors, strange IV behaviour, , , , Unknown 
1.) No events recorded for strixel sensors (run001). They seem to be damaged like they were at DESY.
2.) Very strange IV behaviour for every old Infineon module (especially TB12_baby1). 
Entry  Sat Nov 22 19:29:40 2014, Axel König, AIDA, DUT Position, , , , , Unknown AIDA_DUT_Position.JPG
 
Entry  Sun Nov 23 09:49:00 2014, Markus Friedl, Belle SVD, cooling, , , , , Unknown temp_last_night.png
Saturday evening, the cooling became unstable which indicates the end of the CO2 supply, possibly having a mixture of liquid and gas phases.
Strange oscillations observed for the DUT temperatures until the MF valve was finally turned off close to midnight.
 
Entry  Sun Nov 23 12:39:45 2014, Axel König, common, PMT's of EUDET (Igor Rubinsky), , , , , Unknown 
Der zweite PM (entsprechend der Beamrichtung) war von Anfang an nicht angeschlossen an die TLU! Stattdessen war ein Atlas pixel sensor, welcher
als 4ter PM fungiert angeschlossen. Genau dieser "PM" hatte 0 counts bei der TLU --> Igor sagt, dass dieser Sensor ("PM") anscheinend
keine Versorgungsspannung hatte (~400V). Jetzt baut Igor diesen Atlas Sensor wieder aus und hat bereits den nicht angeschlossenen PM wieder angeschlossen
Entry  Sun Nov 23 15:07:54 2014, Markus Friedl, Belle SVD, common, , , , , Unknown fwbw_setup.png
Geometry setup of FW/BW:
(all dimensions are in mm and refer to the sensor planes)
Entry  Fri Nov 21 23:33:54 2014, Axel König, AIDA, hardware run (PC crashed), AIDA_run008, ---, , , Unknown 
22:00 SVD3 PC crashed!!! data will be collected. 
Entry  Mon Nov 17 22:22:56 2014, Hao Yin, , PedestalRun_001, 001, 10000, Mon Nov 17 22:22:41 CET 2014, , Unknown 
At room temperature.
 
Entry  Tue Nov 18 09:48:53 2014, Hao Yin, Belle SVD, PedestalRun_004, , 10000, Tue Nov 18 09:48:30 CET 2014, , Unknown 
At room temperature.
Old delay settings and FIRRun_002
 
Entry  Tue Nov 18 10:12:25 2014, Hao Yin, Belle SVD, 6let PedestalRun_005, , 10000, Tue Nov 18 10:11:45 CET 2014, , Unknown 
At room temperature
Latest delay, FIRRun002. 
Check for bad strips.
Entry  Fri Nov 21 22:08:32 2014, Hao Yin, , PedestalRun, 013, 10000, , , Unknown 
correct mapping 
cooled -25 °C
L3n deactivated
Entry  Sun Nov 23 10:32:41 2014, Hao Yin, Belle SVD, PedestalRun, 016, 10000, , , Unknown 
Pedestal Run 
room temperature (30C)
Bias scans planned
Entry  Sun Nov 23 15:09:53 2014, Markus Friedl, Belle SVD, PedestalRun, 001, 10000, , , Good 
Initial pedestal run with SVD3 setup and WedgeOld, FW993, BW993 (reading out 4 chips on every p-side)
Entry is currently edited by Thomas Bergauer on 193.170.243.91  Entry  Sun Nov 23 17:51:44 2014, Benedikt Würkner, Belle SVD, HardwareRun, 046, 100000, 20:06, 20:36, Unknown 
Hardware Run +-60V Bias
Room Temperature
Pedestal 018 (again marked all the bad strips)
Entry  Sun Nov 23 15:13:37 2014, Markus Friedl, Belle SVD, HardwareRun, 003, 100600, 23.11.2014 14:07:23, 23.11.2014 16:51:27, Good 
Hardware run, hitting APVs 0/1 on p-sides, 1/2 on n-sides
EUDAT telescope running with difference of 2 events
Entry  Mon Nov 17 23:04:57 2014, Hao Yin, Belle SVD, PedestalRun_002, , 10338, Mon Nov 17 23:03:03 CET 2014, , Unknown 
Pedestal run at room temperature.
6 subevents. Noise reference run.
Delay as latest run.
Entry  Fri Nov 21 15:02:28 2014, Benedikt Würkner, Belle SVD, HardwareRun, 013, 1433, , , Unknown 
cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
Entry  Wed Nov 19 22:15:41 2014, Axel König, Infineon, hardware run, Infineon_run010, 1498709, , , Unknown 
Infineon new stack - batch 4 
 
single hit
 
HV=300V, total I = 4.0200 µA
 
strips vertical
 
Table
Position: H: 92.5mm V: 81mm
 
EUDAQ data: Run951 and Run952
 
data file in L:\cern14\infineon\Infineon
Entry  Wed Nov 19 09:26:39 2014, Axel König, Infineon, hardware run, Infineon_run006, 1500, , , Unknown 
Infineon new stack - batch 4
multi hit
 
HV=300V, total I = 4.0200 µA
 