Wed Nov 19 21:56:44 2014, Axel König, Infineon, hardware run, Infineon_run008, 244167, , , Unknown
|
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0758 µA
strips vertical
Table Position: H: 92.5mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--stopped 19.11 // 21:53 --
Reason: Want to run the eudaq for the next run
Events: 244167 |
Wed Nov 19 22:15:41 2014, Axel König, Infineon, hardware run, Infineon_run010, 1498709, , , Unknown
|
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0200 µA
strips vertical
Table Position: H: 92.5mm V: 81mm
EUDAQ data: Run951 and Run952
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
-- stopped 20.11 / 09:35--
SVD3DAQ Events: 1498709
EUDAQ Events: 2777
EUDAQ stopped counting events --> log entry: "01:38 6-ERROR unexpected trigger number 277714 (expecting 277713)" (TLU Producer) |
Wed Nov 19 22:25:29 2014, Hao Yin, Belle SVD, PedestalRun_008 [CheckLayout], , , , , Unknown
|
cooled (temperature see attachment latest noise run),
latest Noise, FIR settings with the right layout mapping. |
Wed Nov 19 23:15:50 2014, Hao Yin, Belle SVD, HardwareRun_003, , , , , Unknown
|
cooled, latest noise, cal, PedestalRun.
Rawmode |
Wed Nov 19 23:31:08 2014, Hao Yin, Belle SVD, HardwareRun_004, , , , , Unknown
|
Same as HardwareRun_003 but with ZS. |
Thu Nov 20 00:52:50 2014, Hao Yin, Belle SVD, FIRRun_002, , , , , Unknown
|
cooled with new delay run |
Thu Nov 20 00:54:21 2014, Hao Yin, Belle SVD, PedestalRun_008, , , , , Unknown
|
temp see attachment (von flo)
10000
latest fir filter (002) |
Thu Nov 20 00:55:14 2014, Hao Yin, Belle SVD, HardwareRun_007, , , , , Unknown
|
temp cooled see attachment
last noise run(007)
FIRRun_002
PedestalRun_008
new cal run Raw, test with put fifo full flags |
Thu Nov 20 10:22:17 2014, Markus Friedl, Belle SVD, common, , , , , Unknown
|
- Some VME errors occured over night
- Optical fiber changed
- Situation improved
- L3n hybrid could not be configured by I2C
- Plugged cable into the former FWDn slot
- Fully working
|
Thu Nov 20 10:33:13 2014, Benedikt Würkner, Belle SVD, FIRRun and Delay Scan, 003, , , , Unknown
|
Cooled see appendix
with new layout (l3_n-side channels changed and reactivated).
Latest FIRRun |
Thu Nov 20 10:39:11 2014, Benedikt Würkner, Belle SVD, PedestalRun_009, , , , , Unknown
|
cooled see appendix (FIRRun003)
MaxEvents 10000
|
Thu Nov 20 10:39:13 2014, Benedikt Würkner, Belle SVD, PedestalRun_009, , , , , Unknown
|
cooled see appendix (FIRRun003)
MaxEvents 10000
|
Thu Nov 20 10:41:54 2014, Benedikt Würkner, Belle SVD, CalibrationRun_005, , , , , Unknown
|
cooled see appendix (FIRRun_003)
PedestalRun_009 |
Thu Nov 20 15:46:21 2014, Axel König, Infineon, hardware run, Infineon_run012, 263470, , , Unknown
|
Infineon new stack - batch 4
single hit
HV=300V, total I = ? µA
strips vertical
Table Position: H: 89mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--stopped 20.11 // 15:30 --
Eudaq: No Events build --> searching for failure
Events: 263470 |
Thu Nov 20 15:47:56 2014, Axel König, Infineon, hardware run, Infineon_run011, , , , Unknown
|
Infineon new stack - batch 4
faulty!!! |
Thu Nov 20 17:16:56 2014, Axel König, common, how to run the EUDAQ offline monitor, , , , , Unknown
|
YOU need
1.) Folder EUDAQ OFFLINE Monitor
2.) ROOT
Starting:
1.) open command line and chose the path where OfflineMonitor is
2.)Type -i "patch of raw file" -o test.root 100
3.) helpfile typing -h |
Thu Nov 20 18:15:48 2014, Axel König, Infineon, hardware run, Infineon_run013_voltage, 51273, , , Unknown
|
Infineon new stack - batch 4
single hit + eudaq
HV=100V, total I = 3.0326 µA
strips vertical
Table Position: H: 89mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
eudaq file: run000959.raw
--stopped 20.11 // 18:10 --
Eudaq: 54928
Events: 51273 |
Thu Nov 20 22:12:21 2014, Axel König, common, SPS Logbook / SPS Online Monitor, , , , , Unknown
|
Logbook: https://ab-dep-op-elogbook.web.cern.ch/ab-dep-op-elogbook/elogbook/secure/eLogbook.php?shiftId=1059325
Monitor: http://op-webtools.web.cern.ch/op-webtools/vistar/vistars.php?usr=SPS1 |
Fri Nov 21 01:43:54 2014, Axel König, AIDA, calibration run, AIDA_run001_calibration, , , , Unknown
|
Calibration run with AIDA DUT.
Single hit |
Fri Nov 21 11:10:08 2014, Axel König, AIDA, hardware run, AIDA_run002, 211362, , , Unknown
|
AIDA
multi hit
Voltage=100V, I=4.1688uA
(new table calibration): V:56mm, H:96mm
EUDAQ File: Run000962, Run000963, Run000964
config: L:\cern14\AIDA
data: L:\cern14\AIDA
--Stopped 21.11 / 10:30--
DaqEvents: 211362
EUDAQ EVENTS: ca. 41000 |
|