Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle/Infineon/AIDA testbeam at SPS in Nov 2014, Page 3 of 6  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Fri Nov 21 19:05:27 2014, Hao Yin, Belle SVD, FIRRun_004, , , Fri Nov 21 19:05:23 CET 2014, , Unknown 

New ADC delay scan. cooled, -25 temperature

 

Entry  Fri Nov 21 18:35:17 2014, Axel König, AIDA, Important: Dockbox Inverter!, , , , , Unknown 

Alle AIDA runs vor run_007 hatten kein Signal auf den Sensoren 5 und 6.

Grund: Inverter auf N Seite war im config file noch an (von Markus behoben). 

Runs vor 007 können noch verwendet werden obwohl sensoren 5 und 6 negative Events lieferten (kommt aber auf das negative Limit an). 

Entry  Fri Nov 21 18:23:05 2014, Axel König, common, New Table Calibration, , , , , Unknown 

 Nach powercut musste der Tisch neu kalibriert werden. Diese Neukalibration betrifft alle Messungen ab den ersten Messungen vom AIDA Stack.

Entry  Fri Nov 21 18:21:45 2014, Axel König, AIDA, hardware run, AIDA_run006, ~1k, , , Unknown 

 verwerfen!

Entry  Fri Nov 21 18:20:47 2014, Axel König, AIDA, hardware run, AIDA_run005, 20045, , , Unknown 

AIDA

single hit

Voltage=100V, I=5.4357uA

(new table calibration): V:71mm, H:80mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000979

--Stopped 21.11 / 12:12--

DaqEvents: 20045 (-600 ped)

EUDAQ EVENTS: ~18k

Entry  Fri Nov 21 15:37:30 2014, Axel König, AIDA, hardware run, AIDA_run004, 7057, , , Unknown 

AIDA

 

single hit

Voltage=100V, I=5.4357uA

(new table calibration): V:71mm, H:80mm

 

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000977

--Stopped 21.11 / 12:12--

DaqEvents: 7057 (-600 ped)

EUDAQ EVENTS: 4658 (less than Daq) 

Entry  Fri Nov 21 15:10:19 2014, Benedikt Würkner, , HardwareRun, 15-22 (exept 19) , none, , , Crap 
 
Entry  Fri Nov 21 15:07:24 2014, Benedikt Würkner, Belle SVD, HardwareRun, 019, 150948, 2014-11-21 02:41:55, 2014-11-21 10:11:02, Unknown 

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)

VME Error, overnight run

Entry  Fri Nov 21 15:03:08 2014, Benedikt Würkner, Belle SVD, HardwareRun, 014, 989, , , Unknown 

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)
Zero_suppressed

Entry  Fri Nov 21 15:02:28 2014, Benedikt Würkner, Belle SVD, HardwareRun, 013, 1433, , , Unknown 

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)
Zero_suppressed

Entry  Fri Nov 21 12:14:46 2014, Axel König, AIDA, hardware run, AIDA_run003, 20617, , , Unknown 

AIDA

 

single hit

Voltage=100V, I=5.4240uA

(new table calibration): V:66mm, H:74mm

EUDAQ file:  Run000965

config: L:\cern14\AIDA

data: L:\cern14\AIDA

 

--Stopped 21.11 / 12:12--

DaqEvents: 20617 (-600 ped)

EUDAQ EVENTS: 20019 (2 more than DAQ [+2 offset]) 

Entry  Fri Nov 21 11:10:08 2014, Axel König, AIDA, hardware run, AIDA_run002, 211362, , , Unknown 

AIDA

multi hit
Voltage=100V, I=4.1688uA
(new table calibration): V:56mm, H:96mm
 
EUDAQ File: Run000962, Run000963, Run000964
 
config: L:\cern14\AIDA
data: L:\cern14\AIDA
 
--Stopped 21.11 / 10:30--
DaqEvents: 211362
EUDAQ EVENTS: ca. 41000
Entry  Fri Nov 21 01:43:54 2014, Axel König, AIDA, calibration run, AIDA_run001_calibration, , , , Unknown 

Calibration run with AIDA DUT.

Single hit

Entry  Thu Nov 20 22:12:21 2014, Axel König, common, SPS Logbook / SPS Online Monitor, , , , , Unknown 

Logbook: https://ab-dep-op-elogbook.web.cern.ch/ab-dep-op-elogbook/elogbook/secure/eLogbook.php?shiftId=1059325

 

Monitor:  http://op-webtools.web.cern.ch/op-webtools/vistar/vistars.php?usr=SPS1

Entry  Thu Nov 20 22:11:06 2014, Hao Yin, Belle SVD, HardwareRun, 012, , , , Good 

cooled see appendix (FirRun003)

PedestalRun_009

multi 6 Raw Mode

FIFO size increased

Entry  Thu Nov 20 18:15:48 2014, Axel König, Infineon, hardware run, Infineon_run013_voltage, 51273, , , Unknown 

Infineon new stack - batch 4 

single hit + eudaq
 
HV=100V, total I = 3.0326 µA
 
strips vertical
 
Table Position: H: 89mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
eudaq file: run000959.raw
 
--stopped 20.11 // 18:10 --
Eudaq: 54928
Events: 51273
Entry  Thu Nov 20 17:16:56 2014, Axel König, common, how to run the EUDAQ offline monitor, , , , , Unknown 

YOU need

1.) Folder EUDAQ OFFLINE Monitor

2.) ROOT

 

Starting: 

1.) open command line and chose the path where OfflineMonitor is

2.)Type -i "patch of raw file" -o test.root 100

3.) helpfile typing -h

Entry  Thu Nov 20 16:13:18 2014, Hao Yin, Belle SVD, HardwareRun, 011, , , , Crap 

cooled see appendix (FirRun003)

PedestalRun_009

multi 6 Raw Mode

FIFO size increased

 

 

FIFO FULL at  event ~27000

Entry  Thu Nov 20 15:47:56 2014, Axel König, Infineon, hardware run, Infineon_run011, , , , Unknown 

 Infineon new stack - batch 4 

 faulty!!!
Entry  Thu Nov 20 15:46:21 2014, Axel König, Infineon, hardware run, Infineon_run012, 263470, , , Unknown 

Infineon new stack - batch 4 

single hit
 
HV=300V, total I = ? µA
 
strips vertical
 
Table Position: H: 89mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
--stopped 20.11 // 15:30 --
Eudaq: No Events build --> searching for failure
Events: 263470
ELOG V3.1.5-fc6679b