Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle/Infineon/AIDA testbeam at SPS in Nov 2014, Page 2 of 6  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Sat Nov 22 19:29:40 2014, Axel König, AIDA, DUT Position, , , , , Unknown AIDA_DUT_Position.JPG
 
Entry  Sat Nov 22 18:08:03 2014, Axel König, Infineon, hardware run, Infineon_old_run002, 55000, , , Unknown 

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:81mm, H:102mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000993

DaqEvents: 55000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

Entry  Sat Nov 22 17:00:43 2014, Axel König, Infineon, Infineon old, damaged strixel sensors, strange IV behaviour, , , , Unknown 

1.) No events recorded for strixel sensors (run001). They seem to be damaged like they were at DESY.

2.) Very strange IV behaviour for every old Infineon module (especially TB12_baby1). 

Entry  Sat Nov 22 16:53:39 2014, Axel König, Infineon, Infineon old, Infineon_old_run001, 55000 , , , Unknown 

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:81mm, H:97mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000992

DaqEvents: 55000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

Entry  Sat Nov 22 16:43:18 2014, Axel König, common, table, telescope and dut geometry , , , , , Unknown geometry_table.pdfgeometry_DUT.pdfgeometry_infineon_batch4.pdfgeometry_infineon_old.pdf

geometry files

Entry  Sat Nov 22 16:04:05 2014, Axel König, Infineon, Infineon old calibration, Infineon_old_calibration, , , , Unknown 

Calibration run 

L:\cern14\infineon_old

Entry  Sat Nov 22 15:31:49 2014, Hao Yin, Belle SVD, HardwareRun, 038, 43788, 2014-11-22 15:18:40, , Unknown 

Cooled down to -20

Bias voltage set to +-60V

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

Zero suppressed

Entry  Sat Nov 22 11:37:16 2014, Benedikt Würkner, Belle SVD, HardwareRun, 036, 450378, 2014-11-22 1:00:00, 2014-11-22 10:27:54, Unknown SPS_Testbeam-Temp.xlsxScreen_Shot_2014-11-22_at_12.41.44.png

 Not completely cooled since cooling failed at 1:42 in the night

Bias voltage set to +-60V

Some error with event no17 or 18 leading to the data not being easily analysable requiring a hack in TuxOA

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

Entry  Sat Nov 22 11:16:26 2014, Markus Friedl, Belle SVD, cooling, , , , , Unknown 

Cooling box plant hung up (I2C error on Alix, persistent after reboot)

Power-cycled cooling plant, now working

Slowly cooling down again

Entry  Sat Nov 22 10:20:07 2014, Axel König, AIDA, calibration run, AIDA_calibration, , , , Unknown 

Calibration run AIDA_calibration 

L:\cern14\AIDA

Entry  Sat Nov 22 07:56:33 2014, Axel König, AIDA, hardware run, AIDA_run013, 55629, , , Unknown 

AIDA

multi hit

Voltage=100V, I=5.3417uA

(new table calibration): V:51mm, H:45mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000990

DaqEvents: 55629 (-600 ped)

EUDAQ EVENTS: 55003 

 
Entry  Sat Nov 22 00:58:04 2014, Axel König, AIDA, hardware run, AIDA_run012, 276006, , , Unknown 

AIDA

multi hit

Voltage=100V, I=5.3417uA

(new table calibration): V:51mm, H:70mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000989

DaqEvents: 276006 (-600 ped)

EUDAQ EVENTS: 275390 

Entry  Sat Nov 22 00:11:36 2014, Axel König, AIDA, hardware run, AIDA_run011, 24916, , , Unknown 

AIDA

multi hit

Voltage=100V, I=5.3470uA

(new table calibration): V:71mm, H:80mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000988

DaqEvents: 24916 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

Entry  Fri Nov 21 23:40:10 2014, Axel König, AIDA, hardware run, AIDA_run010, 26329, , , Unknown 

  

AIDA

multi hit

Voltage=100V, I=5.3470uA

(new table calibration): V:71mm, H:90mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000987

DaqEvents: 26329 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

 
Entry  Fri Nov 21 23:34:36 2014, Axel König, AIDA, hardware run, AIDA_run009, 32902, , , Unknown 

 

AIDA

multi hit

Voltage=100V, I=5.2190uA

(new table calibration): V:71mm, H:100mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000983

--Stopped 21.11 / 19:20--

DaqEvents: 32902 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

 
Entry  Fri Nov 21 23:33:54 2014, Axel König, AIDA, hardware run (PC crashed), AIDA_run008, ---, , , Unknown 

22:00 SVD3 PC crashed!!! data will be collected. 

Entry  Fri Nov 21 22:08:32 2014, Hao Yin, , PedestalRun, 013, 10000, , , Unknown 

correct mapping

cooled -25 °C

L3n deactivated

 

Entry  Fri Nov 21 19:42:36 2014, Hao Yin, , HardwareRun_033, , , , , Good Temp_21-11-14.PNG

L6 are swapped, needs to be corrected later in the offline analysis.

cooled at -25

latest ADC delay and FIRRun

PedestalRun_012

CalibrationRun_006

100k trigger dead time

 

Need to change L6n apv definition to:

mod = 9,0,1,1,1,m,29,0,0,0,0,0,0,L6_n_side

apv = 9,1,34,3,30,x,0,0,5,1,7,0,0,x
apv = 9,0,36,3,50,x,0,0,5,1,6,0,0,x
apv = 9,3,38,3,30,x,0,0,5,1,9,0,0,x
apv = 9,2,40,3,30,x,0,0,5,1,8,0,0,x

to  get the right mapping of the sensor.

Entry  Fri Nov 21 19:25:57 2014, Axel König, AIDA, hardware run, AIDA_run007, 26770, , , Unknown 

AIDA

multi hit

Voltage=100V, I=5.4357uA

(new table calibration): V:71mm, H:65mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000983

--Stopped 21.11 / 19:20--

DaqEvents: 26770 (-600 ped)

EUDAQ EVENTS: 26171 (+1 trigger offset)

Entry  Fri Nov 21 19:10:09 2014, Hao Yin, Belle SVD, CalibrationRun_006, , , , , Unknown 

cooled, latest ADC delay scan and FIRRun. 

ELOG V3.1.5-fc6679b