Sat Nov 22 16:43:18 2014, Axel König, common, table, telescope and dut geometry , , , , , Unknown
|
geometry files |
Fri Nov 14 19:22:40 2014, Martin Kurz, common, ip addresses, portforwarding, wlan, , , , , Unknown
|
WLAN Router:
SSID: Hephy
password: 20supersecret14
DHCP Range: 192.168.0.200 to 239
Netmask: /24
DNS Server: 192.168.0.254
Gateway: 192.168.0.254
external IP: 128.141.61.16 (für diverse Port Forwardings)
Manuell vergebene IP Adressen bitte unbedingt Martin Kurz mitteilen oder/und in der folgenden Tabelle eintragen!
IP/MAC Zuweisung:
IP |
Machine/Name |
intern |
Port Forwarding (aussen) |
192.168.0.10 |
SVD Kenwood |
VNC(5900) |
VNC(9000) |
192.168.0.11 |
AIDA DAQ |
VNC(5900) |
VNC(9001) |
192.168.0.12 |
TUX DAQ |
VNC(5900), VNC(5901), SSH(22) |
VNC(9009), VNC(9002), SSH(9003), |
192.168.0.13 |
Belle XY Tisch |
|
|
192.168.0.14 |
TUXOA |
SSH(22) |
SSH(9004) |
192.168.0.15 |
JTAG Server |
|
|
192.168.0.148 |
alixcool |
|
|
192.168.0.16 |
slowcontrol |
VNC(5900) |
VNC(9005) |
192.168.0.144 |
CAEN Power supply |
|
|
192.168.0.17 |
zenpixelwiki |
SSH(22), VNC(5900) |
SSH(9006), VNC(9008) |
192.168.0.18 |
TLU (pcx25042, XY) |
VNC(5900) |
VNC(9007) |
192.168.0.240 |
NI GPIB - ENET / 1000 |
|
|
192.168.0.150 |
Printserver |
VNC(5900) |
VNC(9010) |
|
|
|
|
|
|
|
|
Admin Zugang Wlan Router:
IP: 192.168.0.254
Username: admin
password: Hephy2014
|
Fri Nov 14 19:52:12 2014, Thomas Bergauer, , important web pages, , , , , Unknown
|
SPS Accelerator status: http://op-webtools.web.cern.ch/op-webtools/vistar/vistars.php?usr=SPS1
general Information about the Beam line(s): http://sba.web.cern.ch/sba/ |
Thu Nov 20 17:16:56 2014, Axel König, common, how to run the EUDAQ offline monitor, , , , , Unknown
|
YOU need
1.) Folder EUDAQ OFFLINE Monitor
2.) ROOT
Starting:
1.) open command line and chose the path where OfflineMonitor is
2.)Type -i "patch of raw file" -o test.root 100
3.) helpfile typing -h |
Fri Nov 21 23:33:54 2014, Axel König, AIDA, hardware run (PC crashed), AIDA_run008, ---, , , Unknown
|
22:00 SVD3 PC crashed!!! data will be collected. |
Tue Nov 18 13:13:53 2014, Thomas Bergauer, Infineon, hardware run, infineon_run001, 225508, , , Unknown
|
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.2475 µA
strips horizontal
data file in L:\cern14\infineon\Infineon Run horiz
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
STOPPED by main User in H6B (18:11, 15:00)
Events: 225508
Next step: rearange modules vertically
|
Tue Nov 18 18:33:31 2014, Axel König, Infineon, hardware run, Infineon_run003, 300000, , , Unknown
|
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0044 µA
strips vertical
Table Position: H: 96mm V: 101mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--Stopped 18.11 / 20:20---
Reason: Enough events, adjusting new DUT position for next run
Events: 300000 |
Tue Nov 18 23:04:34 2014, Axel König, Infineon, hardware run, Infineon_run004, 400000, , , Unknown
|
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0044 µA
strips vertical
Table Position: H: 96mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--stopped 18.11 // 23:05---
Reason: Enough events, next run with the same position but now multi six
Events: 400000
|
Wed Nov 19 00:58:27 2014, Axel König, Infineon, hardware run, Infineon_run005, 87000, , , Unknown
|
Infineon new stack - batch 4
multi hit
HV=300V, total I = 4.0200 µA
strips vertical
Table Position: H: 96mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
--stopped 19.11 // 01:00 --
Reason: Enough events, new dut postion for next multi run
Events: 87000 |
Wed Nov 19 09:26:39 2014, Axel König, Infineon, hardware run, Infineon_run006, 1500, , , Unknown
|
Infineon new stack - batch 4
multi hit
HV=300V, total I = 4.0200 µA
strips vertical
Table Position: H: 96mm V: 91mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
-- stopped --
1500 Events only --> no trigger signals from TU (01:30 Uhr) |
Wed Nov 19 21:56:44 2014, Axel König, Infineon, hardware run, Infineon_run008, 244167, , , Unknown
|
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0758 µA
strips vertical
Table Position: H: 92.5mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--stopped 19.11 // 21:53 --
Reason: Want to run the eudaq for the next run
Events: 244167 |
Wed Nov 19 22:15:41 2014, Axel König, Infineon, hardware run, Infineon_run010, 1498709, , , Unknown
|
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0200 µA
strips vertical
Table Position: H: 92.5mm V: 81mm
EUDAQ data: Run951 and Run952
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
-- stopped 20.11 / 09:35--
SVD3DAQ Events: 1498709
EUDAQ Events: 2777
EUDAQ stopped counting events --> log entry: "01:38 6-ERROR unexpected trigger number 277714 (expecting 277713)" (TLU Producer) |
Thu Nov 20 15:46:21 2014, Axel König, Infineon, hardware run, Infineon_run012, 263470, , , Unknown
|
Infineon new stack - batch 4
single hit
HV=300V, total I = ? µA
strips vertical
Table Position: H: 89mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--stopped 20.11 // 15:30 --
Eudaq: No Events build --> searching for failure
Events: 263470 |
Thu Nov 20 15:47:56 2014, Axel König, Infineon, hardware run, Infineon_run011, , , , Unknown
|
Infineon new stack - batch 4
faulty!!! |
Thu Nov 20 18:15:48 2014, Axel König, Infineon, hardware run, Infineon_run013_voltage, 51273, , , Unknown
|
Infineon new stack - batch 4
single hit + eudaq
HV=100V, total I = 3.0326 µA
strips vertical
Table Position: H: 89mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
eudaq file: run000959.raw
--stopped 20.11 // 18:10 --
Eudaq: 54928
Events: 51273 |
Fri Nov 21 11:10:08 2014, Axel König, AIDA, hardware run, AIDA_run002, 211362, , , Unknown
|
AIDA
multi hit
Voltage=100V, I=4.1688uA
(new table calibration): V:56mm, H:96mm
EUDAQ File: Run000962, Run000963, Run000964
config: L:\cern14\AIDA
data: L:\cern14\AIDA
--Stopped 21.11 / 10:30--
DaqEvents: 211362
EUDAQ EVENTS: ca. 41000 |
Fri Nov 21 12:14:46 2014, Axel König, AIDA, hardware run, AIDA_run003, 20617, , , Unknown
|
AIDA
single hit
Voltage=100V, I=5.4240uA
(new table calibration): V:66mm, H:74mm
EUDAQ file: Run000965
config: L:\cern14\AIDA
data: L:\cern14\AIDA
--Stopped 21.11 / 12:12--
DaqEvents: 20617 (-600 ped)
EUDAQ EVENTS: 20019 (2 more than DAQ [+2 offset]) |
Fri Nov 21 15:37:30 2014, Axel König, AIDA, hardware run, AIDA_run004, 7057, , , Unknown
|
AIDA
single hit
Voltage=100V, I=5.4357uA
(new table calibration): V:71mm, H:80mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: Run000977
--Stopped 21.11 / 12:12--
DaqEvents: 7057 (-600 ped)
EUDAQ EVENTS: 4658 (less than Daq) |
Fri Nov 21 18:20:47 2014, Axel König, AIDA, hardware run, AIDA_run005, 20045, , , Unknown
|
AIDA
single hit
Voltage=100V, I=5.4357uA
(new table calibration): V:71mm, H:80mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: Run000979
--Stopped 21.11 / 12:12--
DaqEvents: 20045 (-600 ped)
EUDAQ EVENTS: ~18k |
Fri Nov 21 18:21:45 2014, Axel König, AIDA, hardware run, AIDA_run006, ~1k, , , Unknown
|
verwerfen! |
|