Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle/Infineon/AIDA testbeam at SPS in Nov 2014, Page 1 of 6  Not logged in ELOG logo
ID Date Author Project Subject Run Numberdown Events StartTime EndTime Data
  29   Tue Nov 18 13:13:53 2014 Thomas BergauerInfineonhardware runinfineon_run001225508  Unknown

Infineon new stack - batch 4

single hit
 
HV=300V, total I = 4.2475 µA
 
strips horizontal
 
data file in L:\cern14\infineon\Infineon Run horiz
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
 
STOPPED by main User in H6B (18:11, 15:00)
 
Events: 225508
Next step: rearange modules vertically
 
  98   Sat Nov 22 17:00:43 2014 Axel KönigInfineonInfineon olddamaged strixel sensors, strange IV behaviour   Unknown

1.) No events recorded for strixel sensors (run001). They seem to be damaged like they were at DESY.

2.) Very strange IV behaviour for every old Infineon module (especially TB12_baby1). 

  65   Thu Nov 20 18:15:48 2014 Axel KönigInfineonhardware runInfineon_run013_voltage51273  Unknown

Infineon new stack - batch 4 

single hit + eudaq
 
HV=100V, total I = 3.0326 µA
 
strips vertical
 
Table Position: H: 89mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
eudaq file: run000959.raw
 
--stopped 20.11 // 18:10 --
Eudaq: 54928
Events: 51273
  61   Thu Nov 20 15:46:21 2014 Axel KönigInfineonhardware runInfineon_run012263470  Unknown

Infineon new stack - batch 4 

single hit
 
HV=300V, total I = ? µA
 
strips vertical
 
Table Position: H: 89mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
--stopped 20.11 // 15:30 --
Eudaq: No Events build --> searching for failure
Events: 263470
  62   Thu Nov 20 15:47:56 2014 Axel KönigInfineonhardware runInfineon_run011   Unknown

 Infineon new stack - batch 4 

 faulty!!!
  45   Wed Nov 19 22:15:41 2014 Axel KönigInfineonhardware runInfineon_run0101498709  Unknown

Infineon new stack - batch 4 

 
single hit
 
HV=300V, total I = 4.0200 µA
 
strips vertical
 
Table Position: H: 92.5mm V: 81mm
 
EUDAQ data: Run951 and Run952
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
 
-- stopped 20.11 / 09:35-- 
 
SVD3DAQ Events: 1498709
EUDAQ Events: 2777
 
EUDAQ stopped counting events --> log entry: "01:38 6-ERROR unexpected trigger number 277714 (expecting 277713)" (TLU Producer)
  44   Wed Nov 19 21:56:44 2014 Axel KönigInfineonhardware runInfineon_run008244167  Unknown

Infineon new stack - batch 4 

single hit
 
HV=300V, total I = 4.0758 µA
 
strips vertical
 
Table Position: H: 92.5mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
--stopped 19.11 // 21:53 --
Reason: Want to run the eudaq for the next run
Events: 244167
  40   Wed Nov 19 18:20:29 2014 Axel KönigInfineoncalibration runInfineon_run007_cal   Unknown
  38   Wed Nov 19 09:26:39 2014 Axel KönigInfineonhardware runInfineon_run0061500  Unknown

Infineon new stack - batch 4

multi hit
 
HV=300V, total I = 4.0200 µA
 
strips vertical
 
Table Position: H: 96mm V: 91mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
 
-- stopped --
1500 Events only --> no trigger signals from TU (01:30 Uhr)
  37   Wed Nov 19 00:58:27 2014 Axel KönigInfineonhardware runInfineon_run00587000  Unknown

Infineon new stack - batch 4 

multi hit
 
HV=300V, total I = 4.0200 µA
 
strips vertical
 
Table Position: H: 96mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
 
--stopped 19.11 // 01:00 --
Reason: Enough events, new dut postion for next multi run
Events: 87000
  36   Tue Nov 18 23:04:34 2014 Axel KönigInfineonhardware runInfineon_run004400000  Unknown

Infineon new stack - batch 4 

single hit
 
HV=300V, total I = 4.0044 µA
 
strips vertical
 
Table Position: H: 96mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
--stopped 18.11 // 23:05---
Reason: Enough events, next run with the same position but now multi six
Events: 400000
 
  31   Tue Nov 18 18:33:31 2014 Axel KönigInfineonhardware runInfineon_run003300000  Unknown

Infineon new stack - batch 4

single hit

HV=300V, total I = 4.0044 µA

strips vertical

Table Position: H: 96mm V: 101mm

data file in L:\cern14\infineon\Infineon Run vert

config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg

 

--Stopped 18.11 / 20:20---

Reason: Enough events, adjusting new DUT position for next run

Events: 300000

  30   Tue Nov 18 18:29:55 2014 Axel KönigInfineoncalibration runInfineon_run002   Unknown

Infineon_run002 is just a calibration run for the vertical positioned sensors. 

data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
  107   Sun Nov 23 09:32:48 2014 Axel KönigInfineonhardware runInfineon_old_run00763913  Unknown

Infineon old

multi hit

Voltage=300V, I=10.4028uA

(new table calibration): V:75, H:96.5

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000999

DaqEvents: 63913 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset)  

  108   Sun Nov 23 09:36:27 2014 Axel KönigInfineonhardware runInfineon_old_run006526562  Unknown

Infineon old

multi hit

Voltage=300V, I=10.4028uA

(new table calibration): V:75, H:95

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000998

DaqEvents: 526562 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset)  

  103   Sun Nov 23 00:51:07 2014 Axel KönigInfineonhardware runInfineon_old_run00526569  Unknown

Infineon old

multi hit

Voltage=300V, I=10.4609uA

(new table calibration): V:75, H:94.5

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000997

DaqEvents: 26569 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

 
  102   Sun Nov 23 00:24:15 2014 Axel KönigInfineonhardware runInfineon_old_run004168725  Unknown

Infineon old

multi hit

Voltage=300V, I=10.6529uA

(new table calibration): V:81, H:88

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000996

DaqEvents: 168725 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

  101   Sun Nov 23 00:20:41 2014 Axel KönigInfineonhardware runInfineon_old_run00330000  Unknown

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:?, H:?

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000994

DaqEvents: 30000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

  99   Sat Nov 22 18:08:03 2014 Axel KönigInfineonhardware runInfineon_old_run00255000  Unknown

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:81mm, H:102mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000993

DaqEvents: 55000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

  97   Sat Nov 22 16:53:39 2014 Axel KönigInfineonInfineon oldInfineon_old_run00155000   Unknown

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:81mm, H:97mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000992

DaqEvents: 55000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

ELOG V3.1.5-fc6679b