52
|
Tue Oct 23 08:22:42 2012 |
Markus Friedl | MicronOrigami_gross | run | run025 | 100000 | 23.10.2012 08:21:37 | 23.10.2012 13:47:09 | Good | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2
HV = +-15V, Ibias=47uA
Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
= p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
= n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1 |
53
|
Tue Oct 23 13:50:44 2012 |
Markus Friedl | MicronOrigami_gross | cal | cal025 | 83800 | 23.10.2012 13:47:09 | 23.10.2012 14:35:05 | Good | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2
HV = +-15V, Ibias=48uA
Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
= p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
= n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1 |
54
|
Tue Oct 23 15:55:58 2012 |
Markus Friedl | MicronOrigami_gross | cal | cal026 | 83800 | 23.10.2012 14:56:47 | 23.10.2012 15:42:17 | Good | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2
HV = +-10V, Ibias=36uA
Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
= p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
= n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1 |
60
|
Sat Oct 27 00:43:55 2012 |
Christian Irmler | MicronBaby | cal | cal029 | 83800 | 27.10.2012 00:10:15 | 27.10.2012 00:36:55 | Good | After irradiation
Micron baby stack after gamma irrdiation
HV = -100 V
I = -58 uA |
61
|
Sat Oct 27 01:13:47 2012 |
Christian Irmler | MicronBaby | run | run029 | 307k | 27.10.2012 01:02:49 | 27.10.2012 07:36:34 | Good | After irradiation
xy-table: x=319.4, y=74.6
beam hits APV0
Micron baby stack after gamma irrdiation
HV = -100 V
I = -58 uA |
62
|
Sat Oct 27 07:51:49 2012 |
Manfred Valentan | MicronBaby | run | run030 | 376678 | 27.10.2012 07:49:09 | 27.10.2012 17:32:07 | Good | After irradiation
xy-table: x=319.4, y=87.6
beam hits APV1
Micron baby stack after gamma irrdiation
HV = -100 V
I = -58 uA |
63
|
Sat Oct 27 19:36:24 2012 |
Markus Friedl | MicronOrigami_gross | cal | cal031 | 83800 | 27.10.2012 19:59:50 | 27.10.2012 20:44:38 | Good | Belle stack 2 after irradiation
HV = +50V -50V
I = 112 µA
CO2 cooling |
64
|
Sat Oct 27 21:49:08 2012 |
Markus Friedl | MicronOrigami_gross | run | run031 | 150k | 27.10.2012 21:42:46 | 28.10.2012 02:35:55 (+1h due to winter time) | Good | Belle stack 2 after gamma irrdiation
HV = +50V -50 V
I = 102 uA
CO2 cooling
|
65
|
Sun Oct 28 02:51:49 2012 |
Markus Friedl | MicronOrigami_gross | run | run032 | 150k | 28.10.2012 02:47:24 | 28.10.2012 08:31:19 | Good | Belle stack 2 after gamma irradiation
HV = +50V -50V
I = 101 uA
Bias currents absolutely stable during the whole run.
CO2 cooling
hitting APV3 (n side) = wide side of wedge sensor |
67
|
Sun Oct 28 15:46:07 2012 |
Markus Friedl | MicronBaby | cal | cal034 | 83800 | 28.10.2012 15:19:10 | 28.10.2012 15:40:47 | Good | Micron Baby stack 2 after irradiation (intermediate strips)
HV = -100 V
I = 33 uA |
68
|
Sun Oct 28 16:22:35 2012 |
Christian Irmler | MicronBaby | run | run034 | 101864 | 28.10.2012 16:12:24 | 28.10.2012 18:34:24 | Good | Micron Baby stack 2 after irradiation (intermediate strips)
HV = -100 V
I = 36.3 uA
Position APV0 of all sensors
X-Y Table coordinates:
X=0 / Y=-1 (afterwards: nulled)
PC power cut after ~100k events |
69
|
Sun Oct 28 20:07:28 2012 |
Markus Friedl | MicronBaby | run | run035 | 304110 | 28.10.2012 20:01:48 | 29.10.2012 03:50:44 | Good | Micron Baby stack 2 after irradiation (intermediate strips)
HV = -100 V
I = 39 uA
DESY table shifted by 2.5mm (beam down) after beam profile was changed (to get higher intensity)
beam hitting lower APVs |
71
|
Mon Oct 29 11:36:40 2012 |
Markus Friedl | Infineon | cal | cal037 | 83800 | 29.10.2012 11:35:12 | 29.10.2012 11:58:02 | Good | Infineon stack Version 2 after irradiation
HV = +300 V
I = 137 A
|
72
|
Mon Oct 29 12:24:41 2012 |
Markus Friedl | Infineon | run | run037 | 301382 | 29.10.2012 12:22:22 | 29.10.2012 21:05:57 | Good | Infineon stack Version 2 after irradiation
HV = +300 V
I = 162 A
hitting upper part of strixels and baby, vertically ~centered |
73
|
Mon Oct 29 22:36:52 2012 |
Markus Friedl | HPK_baby | cal | cal038 | 83800 | 29.10.2012 22:17:34 | 29.10.2012 22:47:47 | Good | HPK baby stack after irradiation with partial cooling (HPK neutron & HPK neutron/gamma)
HV = +75 Vm -75V
I = 226A
Temp sensors configuration:
11 HPK Neutron n in
12 HPK Neutron n -> p
13 ----
14 HPK Neutron p -> Gamma p
15 Gamma p -> n
16 Neutron Gamma n out |
75
|
Tue Oct 30 10:37:19 2012 |
Markus Friedl | HPK_baby | cal | cal039 | 83800 | 30.10.2012 10:35:35 | 30.10.2012 11:02:06 | Good | Turned off cooling, now taking warm data
HPK baby stack after irradiation - no cooling
I = 200A and growing (warming up)
positioned centered on p and n
|
22
|
Mon Oct 15 19:40:03 2012 |
Marko Dragicevic | MicronOrigami_gross | run ATTENTION: wrong bias voltage | run009 | 31650 | 15.10.2012 19:28:30 | 15.10.2012 22:08:31 | Crap | ATTENTION! Bias voltage was +-100 V instead of +-50 V
Origami Stack 2: Origami #4, #3, Wedge new1, old
HV = +-100V
Ibias=12.3µA
beam position:
vertical: between APV 1&2 (of 6)
horizontal: centered on APV#1 -> right side of sensor
Position of xy table:
x = 23, y = -25
Temperatures:
Origami #4: In=-33 degC / Out=-34 degC
Origami #3: Out=-35 degC (temperatur sensor of inlet is not working)
Wedge new 1: Out = -17 degC, cooling block = -14 degC
Wedge old: Out = -16 degC, cooling block = -14 degC
15.10.2012 22:08:31 event=0 rate=0events/s temp/curr=31.3/089.2 31.3/-16.2 31.2/-17.9 31.3/-18.2 29.9/003.6 29.9/003.1 30.0/-01.1 29.9/-01.6
Stopped after 31650 events, because of PS problems and no beam. |
24
|
Mon Oct 15 23:26:52 2012 |
Marko Dragicevic | MicronOrigami_gross | run ATTENTION: wrong bias voltage | run010 | 158k | 15.10.2012 23:10:40 | 16.10.2012 05:05:35 | Crap | ATTENTION: Bias voltage was +-100 V instead of +- 50 V
Same as run009.
Origami Stack 2: Origami #4, #3, Wedge new1, old
HV = +-10V
Ibias=12.3µA
beam position:
vertical: between APV 1&2 (of 6)
horizontal: centered on APV#1 -> right side of sensor -> small side of wedge sensors
Position of xy table:
x = 23, y = -25
Temperatures:
Origami #4: In=-33 degC / Out=-34 degC
Origami #3: Out=-35 degC (temperatur sensor of inlet is not working)
Wedge new 1: Out = -17 degC, cooling block = -14 degC
Wedge old: Out = -16 degC, cooling block = -14 degC
15.10.2012 22:08:31 event=0 rate=0events/s temp/curr=31.3/089.2 31.3/-16.2 31.2/-17.9 31.3/-18.2 29.9/003.6 29.9/003.1 30.0/-01.1 29.9/-01.6
|
25
|
Tue Oct 16 05:24:21 2012 |
Christian Irmler | MicronOrigami_gross | run ATTENTION: wrong bias voltage | run011 | 150k | 16.10.2012 05:19:28 | 16.10.2012 09:59:24 | Crap | ATTENTION: Bias voltage was +-100 V instead of +- 50 V
Origami Stack 2: Origami #4, #3, Wedge new1, old
HV = +-100V
Ibias=12.3µA
beam position:
vertical: between APV 1&2 (of 6)
horizontal: centered on APV#3 -> left side of sensor -> wide side of wedge sensors
Position of xy table:
x = 83, y = -25
Temperatures:
Origami #4: In=-33 degC / Out=-34 degC
Origami #3: Out=-35 degC (temperatur sensor of inlet is not working)
Wedge new 1: Out = -17 degC, cooling block = -16 degC
Wedge old: Out = -15 degC, cooling block = -15 degC
Stopped after 132658 events, because of empty gas bottle and thus insufficient cooling. |
37
|
Fri Oct 19 00:45:52 2012 |
Markus Friedl | MicronOrigami_gross | run | run016 | 11855 | 19.10.2012 00:24:05 | 19.10.2012 00:48:24 | Crap |
Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2
HV = +-50V, Ibias=77A
Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
= p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
= n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1
Stack is now positioned on globally best performing position which should also enable reasonable tracking.
Trigger timing not perfect, needs adjustment (-1 CLK) -> new run |
|