| ID | Date | Author | Project | Subject  | Run Number | Events | StartTime | EndTime | Data |  | 41 | Sat Oct 20 11:40:13 2012 | Markus Friedl | MicronOrigami_gross | run | run019 | 100000 | 20.10.2012  11:38:19 | 20.10.2012  19:20:51 | Good |  | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2HV = +-45V, Ibias=72A
 Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
 = p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
 = n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1
 Several periods without beam during this run. |  | 42 | Sat Oct 20 19:35:30 2012 | Markus Friedl | MicronOrigami_gross | run | run020 | 300000 | 20.10.2012  19:34:19 | 21.10.2012  08:55:28 | Good |  | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2HV = +-40V, Ibias=73A
 Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
 = p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
 = n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1
   |  | 45 | Sun Oct 21 10:39:15 2012 | Markus Friedl | MicronOrigami_gross | run | run021 | 100000 | 21.10.2012  10:37:26 | 21.10.2012  15:04:49 | Good |  | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2HV = +-35V, Ibias=69uA
 Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
 = p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
 = n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1
   |  | 47 | Sun Oct 21 16:04:06 2012 | Markus Friedl | MicronOrigami_gross | run | run022 | 151282 | 21.10.2012  18:16:53 | 22.10.2012  00:04:42 | Good |  | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2HV = +-30V, Ibias=70uA
 Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
 = p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
 = n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1
 |  | 49 | Mon Oct 22 00:57:05 2012 | Markus Friedl | MicronOrigami_gross | run | run023 | 176629 | 22.10.2012  00:55:59 | 22.10.2012  10:04:38 | Good |  | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2HV = +-25V, Ibias=65uA
 Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
 = p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
 = n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1
 No more events since 22.10.2012  07:09:53  event=176629 - spill signals removed?   |  | 51 | Mon Oct 22 19:19:53 2012 | Markus Friedl | MicronOrigami_gross | run | run024 | 260000 | 22.10.2012  19:18:16 | 23.10.2012  08:17:20 | Good |  | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2HV = +-20V, Ibias=57uA
 Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
 = p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
 = n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1
   Beam shape on n side (horizontally) different than in previous runs. Number of triggers per spill is reduced to ~60k (was 200..250k before). Reason unknown. |  | 52 | Tue Oct 23 08:22:42 2012 | Markus Friedl | MicronOrigami_gross | run | run025 | 100000 | 23.10.2012  08:21:37 | 23.10.2012  13:47:09 | Good |  | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2HV = +-15V, Ibias=47uA
 Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
 = p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
 = n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1
 |  | 55 | Tue Oct 23 16:06:09 2012 | Markus Friedl | MicronOrigami_gross | run | run026 | 102124 | 23.10.2012  16:04:47 | 23.10.2012  23:04:56 | Unknown |  | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2HV = +-10V, Ibias=36uA
 Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
 = p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
 = n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1
 
 
    
        
            | SPS Status during whole run: Still problems with North Area steering. means that beam position was not stable. |  |  | 56 | Tue Oct 23 23:12:03 2012 | Thomas Bergauer | MicronOrigami_gross | run | run027 | 220847 | 23.10.2012  23:10:14 | 24.10.2012  08:19:51 | Unknown |  |  Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2 HV = +-5V, Ibias=23.5uA Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29 = p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3 = n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1   SPS Status during whole run: Still problems with North Area steering. means that beam position was not stable. |  | 61 | Sat Oct 27 01:13:47 2012 | Christian Irmler | MicronBaby | run | run029 | 307k | 27.10.2012  01:02:49 | 27.10.2012  07:36:34 | Good |  | After irradiation xy-table: x=319.4, y=74.6beam hits APV0
 Micron baby stack after gamma irrdiationHV = -100 V
 I = -58 uA
 |  | 62 | Sat Oct 27 07:51:49 2012 | Manfred Valentan | MicronBaby | run | run030 | 376678 | 27.10.2012  07:49:09 | 27.10.2012  17:32:07 | Good |  | After irradiation xy-table: x=319.4, y=87.6beam hits APV1
 Micron baby stack after gamma irrdiationHV = -100 V
 I = -58 uA
 |  | 64 | Sat Oct 27 21:49:08 2012 | Markus Friedl | MicronOrigami_gross | run | run031 | 150k | 27.10.2012  21:42:46 | 28.10.2012  02:35:55 (+1h due to winter time) | Good |  | Belle stack 2 after gamma irrdiationHV = +50V -50 V
 I = 102 uA
 CO2 cooling
   |  | 65 | Sun Oct 28 02:51:49 2012 | Markus Friedl | MicronOrigami_gross | run | run032 | 150k | 28.10.2012  02:47:24 | 28.10.2012  08:31:19 | Good |  | Belle stack 2 after gamma irradiation HV = +50V -50V I = 101 uA Bias currents absolutely stable during the whole run. CO2 cooling hitting APV3 (n side) = wide side of wedge sensor |  | 66 | Sun Oct 28 08:37:53 2012 | Christian Irmler | MicronOrigami_gross | run | run033 | 66937 | 28.10.2012  08:33:42 | 28.10.2012  14:10:43 | Unknown |  | Belle stack 2 after gamma irradiation HV = +50V -50V I = 101 uA CO2 cooling hitting APV2 (n side) = center of wedge sensor   Temperatur sensors: 
    T11: Origami #4 inT12: Origami #4 outT13: Origami #3 in (still wrong values!)T14: Origami #3 outT15: Wedge new 1 outT16: Wedge old outT17: Wedge new 1 cooling blockT18: Wedge old cooling block |  | Attachment 1: temp_run33.JPG |  |  |  | Attachment 2: temp_run33_2.JPG |  |  |  | 68 | Sun Oct 28 16:22:35 2012 | Christian Irmler | MicronBaby | run | run034 | 101864 | 28.10.2012  16:12:24 | 28.10.2012  18:34:24 | Good |  | Micron Baby stack 2 after irradiation (intermediate strips)HV = -100 V
 I = 36.3 uA
 Position APV0 of all sensors X-Y Table coordinates:X=0 / Y=-1  (afterwards: nulled)
 PC power cut after ~100k events |  | 69 | Sun Oct 28 20:07:28 2012 | Markus Friedl | MicronBaby | run | run035 | 304110 | 28.10.2012  20:01:48 | 29.10.2012  03:50:44 | Good |  | Micron Baby stack 2 after irradiation (intermediate strips)HV = -100 V
 I = 39 uA
 
 DESY table shifted by 2.5mm (beam down) after beam profile was changed (to get higher intensity) beam hitting lower APVs |  | 70 | Mon Oct 29 04:02:16 2012 | Manfred Valentan | MicronBaby | run | run036 | 296294 | 29.10.2012  03:53:33 | 29.10.2012  11:05:35 | Unknown |  | Micron Baby stack 2 after irradiation (intermediate strips)HV = -100 V
 I = 36 uA
 
 DESY table shifted by 2.5mm (beam down) after beam profile was changed (to get higher intensity) beam hitting higher APVs   Stopped when long beam off period was announced |  | 72 | Mon Oct 29 12:24:41 2012 | Markus Friedl | Infineon | run | run037 | 301382 | 29.10.2012  12:22:22 | 29.10.2012  21:05:57 | Good |  | Infineon stack Version 2 after irradiationHV = +300 V
 I = 162 A
 
 hitting upper part of strixels and baby, vertically ~centered |  | 74 | Mon Oct 29 23:13:52 2012 | Markus Friedl | HPK_baby | run | run038 | 476500 | 29.10.2012  23:13:05 | 30.10.2012  10:22:54 | Unknown |  | HPK baby stack after irradiation with partial cooling (HPK neutron & HPK neutron/gamma)HV = +75 V  -75V
 I =  176A
 positioned centered on p and n
 
 Temp sensors configuration: 11   HPK Neutron n in 12   HPK Neutron n -> p 13   ---- 14   HPK Neutron p -> Gamma p 15   Gamma p -> n 16   Neutron Gamma n out   Perfect cooling curve :-) 
 |  | 76 | Tue Oct 30 11:05:32 2012 | Markus Friedl | HPK_baby | run | run039 | 150k | 30.10.2012  11:03:19 | 30.10.2012  14:57:57 | Unknown |  | HPK baby stack after irradiation - no coolingI =  420A and growing (warming up)
 positioned centered on p and n
 
 
 |  |