Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  HEPHY logbook for testbeam at SPS September/October 2010, Page 8 of 8  Not logged in ELOG logo
ID Date Author Project Subject Run Number Eventsdown StartTime EndTime
  110   Mon Oct 11 11:18:17 2010 Christian Irmlercommonend of success  09.10.2010 19:44:23NaN

der Beiweis  :-)

Attachment 1: IMG_9033.JPG
IMG_9033.JPG
  111   Tue Oct 19 14:58:56 2010 Manfred ValentanMicron Babygeometry    
Attachment 1: IMG_8888.JPG
IMG_8888.JPG
Attachment 2: micron_baby_stack_telescope_geometry.JPG
micron_baby_stack_telescope_geometry.JPG
Attachment 3: micron_baby_stack_telectope_geometry.dwg
  112   Thu Mar 31 10:28:19 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, pre zupfcal100 31.03.2011 10:24:5931.03.2011 10:33:15

DUT5
cal-file: micronbaby_single_irrad_cal100.cfg


HV=+-50V
90Sr 1mCi ~centered
I_start=99muA
I_end=103muA

 

  114   Thu Mar 31 12:11:04 2011 Manfred ValentanMicron BabyDUT4, source run, post irrad, pre zupfcal101 31.03.2011 12:09:3631.03.2011 12:17:52

DUT4
config file: micronbaby_single_irrrad_cal101.cfg


HV=+-50V
90Sr 1mCi ~centered
I_start=128µA
I_end=140µA

 

  116   Fri Apr 8 13:25:58 2011 Manfred ValentanMicron Babysensors and modules    

TRK1: B2Micron_2826_1_baby2

TRK2: B2Micron_2826_1_baby3

DUT3: B2Micron_2826_7_baby2 (common p-stop)

DUT4: B2Micron_2826_19_baby4 (combined p-stop)

DUT5: B2Micron_2826_19_baby3 (atoll p-stop)

TRK6: B2Micron_2826_1_baby4

TRK7: B2Micron_2826_19_baby2

GEW: B2Micron_2826_7_baby4

not used: B2Micron_2826_7_baby3

  120   Wed May 4 15:14:31 2011 Thomas BergauerPtinfo about module    

pt-Modul hat jeweils zwei OB1 Sensoren von STM (mit 122um Pitch)

im Abstand von 2mm uebereinander

  135   Tue May 17 19:08:29 2011 Manfred ValentanMicron Babysensors for source test with intermediate strips    

Every second bond of these sensors will be removed to mimic the effect of an intermediate strip. For comparison, this is done both with irradiated and unirradiated sensors.

DUT3: B2Micron_2826_7_baby2, common p-stop, irradiated

DUT4: B2Micron_2826_19_baby4, combined p-stop, irradiated

DUT5: B2Micron_2826_19_baby3, atoll p-stop, irradiated (Wolfgang T. took this sensor to the SEM, it's destroyed by now)

TRK6: B2Micron_2826_1_baby4, combined p-stop, unirradiated

TRK7: B2Micron_2826_19_baby2, common p-stop, unirradiated

            B2Micron_2826_7_baby3, atoll p-stop, unirradiated

 

ELOG V3.1.5-fc6679b