DUT3: B2Micron_2826_7_baby2 (common p-stop) config file: D:/cern10/micronbaby/data_lab/DUT3/postzupf/micronbaby_multi6_irrad_postzupf.cfg
HV=+-50V 90Sr 1mCi ~centered I_start=18.0µA I_end=22.6µA
Every second bond zupfed
DUT4: B2Micron_2826_19_baby4 (combined p-stop) config file: D:/cern10/micronbaby/data_lab/DUT4/postzupf/micronbaby_multi6_irrad_postzupf.cfg
HV=+-50V 90Sr 1mCi ~centered I_start=141µA I_end=167µA
Every second bond zupfed...
angle scan Origami 1 and Micron wedge 1 HV = 100V chiller set to 14°C
angle: 60° axis 1: 92.4 (horizontal) axis 2: 35 (vertical) axis 3: -52.5 (rotary table)
telescope run: 20149
angle: 30° axis 1: 92.4 (horizontal) axis 2: 35 (vertical) axis 3: -22.5 (rotary table)
telescope run: 20150
angle: 45° axis 1: 92.4 (horizontal) axis 2: 35 (vertical) axis 3: -37.5 (rotary table)
telescope run: 20151
angle: 15° axis 1: 92.4 (horizontal) axis 2: 35 (vertical) axis 3: -7.5 (rotary table)
telescope run: 20152
angle: 0° axis 1: 92.4 (horizontal) axis 2: 35 (vertical) axis 3: +7.5 (rotary table)
telescope run: 20153