Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  HEPHY logbook for testbeam at SPS September/October 2010, Page 3 of 8  Not logged in ELOG logo
ID Date Author Project Subject Run Number Events StartTime EndTimedown
  137   Wed May 18 10:38:07 2011 Manfred ValentanMicron BabyDUT3, source run, irrad, prezupfrun113100k18.05.2011 10:03:1518.05.2011 10:25:14

DUT3: B2Micron_2826_7_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT3/prezupf/micronbaby_single_irrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=20µA
I_end=26µA

  136   Wed May 18 10:12:32 2011 Manfred ValentanMicron BabyDUT3, source run, unirrad, prezupfcal1138380018.05.2011 09:42:0818.05.2011 09:50:23

DUT3: B2Micron_2826_7_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT3/prezupf/micronbaby_single_irrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=13µA
I_end=20µA

  134   Tue May 17 18:53:33 2011 Manfred ValentanMicron BabyB2Micron_2826_7_baby3, source run, unirrad, prezupfrun112100k17.05.2011 19:00:2117.05.2011 19:22:45

DUT candidate atoll p-stop

B2Micron_2826_7_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/7baby3/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.4µA
I_end=1.8µA

n-side: looks very good except for a few strips in the middle of APV5 -> DUT candidate

  133   Tue May 17 18:49:16 2011 Manfred ValentanMicron BabyB2Micron_2826_7_baby3, source run, unirrad, prezupfcal1128380017.05.2011 18:50:5017.05.2011 18:59:04

B2Micron_2826_7_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/7baby3/prezupf/micronbaby_single.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.2µA
I_end=1.4µA

  132   Tue May 17 18:33:07 2011 Manfred ValentanMicron BabyGEW8, source run, unirrad, prezupfrun111100k17.05.2011 18:01:4117.05.2011 18:23:24

NOT usable as DUT

GEW8: B2Micron_2826_7_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/GEW8/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.6µA
I_end=2.2µA

n-side: most of zones 1 and 3 unusable

  131   Tue May 17 17:44:12 2011 Manfred ValentanMicron BabyGEW8, source run, unirrad, prezupfcal1118380017.05.2011 17:51:5017.05.2011 18:00:02

GEW8: B2Micron_2826_7_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/GEW8/prezupf/micronbaby_single.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=1.6µA

  130   Tue May 17 17:43:24 2011 Manfred ValentanMicron BabyTRK7, source run, unirrad, prezupfrun110100k17.05.2011 15:39:3717.05.2011 16:02:54

DUT candidate common p-stop

TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.8µA
I_end=2.1µA

n-side: highest 32 strips of APV5 noisy = half of zone 4. Rest okay, DUT candidate

  129   Tue May 17 15:10:52 2011 Manfred ValentanMicron BabyTRK7, source run, unirrad, prezupfcal1108380017.05.2011 15:16:2517.05.2011 15:24:35

TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/prezupf/micronbaby_single.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=1.7µA

  128   Tue May 17 14:37:23 2011 Manfred ValentanMicron BabyTRK6, source run, unirrad, prezupfrun109100k17.05.2011 14:34:3217.05.2011 15:00:02

DUT candidate combined p-stop

TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.9µA
I_end=2.4µA

n-side zone 2 several unusable strips, zone 3 & 4 32 strips each suspicious. Nevertheless DUT candidate!

  127   Tue May 17 14:36:36 2011 Manfred ValentanMicron BabyTRK6, source run, unirrad, prezupfcal1098380017.05.2011 14:18:1317.05.2011 14:34:25

TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=1.8µA

  126   Tue May 17 14:01:45 2011 Manfred ValentanMicron BabyTRK2, source run, unirrad, prezupfrun108100k17.05.2011 13:28:4817.05.2011 13:51:16

No DUT candidate (atoll p-stop)

TRK2: B2Micron_2826_1_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK2/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=2µA

n-side: APV4 most strips unusable, no DUT candidate

  125   Tue May 17 13:31:32 2011 Manfred ValentanMicron BabyTRK2, source run, unirrad, prezupfcal1088380017.05.2011 13:17:1717.05.2011 13:25:27

TRK2: B2Micron_2826_1_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK2/prezupf/micronbaby_single.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.0µA
I_end=1.3µA

  124   Tue May 17 13:08:08 2011 Manfred ValentanMicron BabyTRK1, source run, unirrad, prezupfrun107100k17.05.2011 12:39:3417.05.2011 13:03:05

DUT candidate common p-stop

TRK1: B2Micron_2826_1_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK1/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=2µA

n-side: half of zones 1 and 4 obsolete due to noisy strips, rest is okay. DUT Candidate

  123   Tue May 17 13:02:34 2011 Manfred ValentanMicron BabyTRK1, source run, unirrad, prezupfcal1078380017.05.2011 12:2017.05.2011 12:35

TRK1: B2Micron_2826_1_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK1/prezupf/micronbaby_single.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=2µA

  119   Wed Apr 13 12:13:09 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, post zupf ** DO NOT USE **cal1058380013.04.2011 12:02:4113.04.2011 12:10:55

DUT5 (atoll), each second bond removed to simulate intermediate strips
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_single_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=18µA
I_end=21.5µA

data recorded with new switching power supplies and old intcal, which doesn't ignore bad strips!!!!!

  121   Wed May 11 16:28:07 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, post zupfrun106100k11.05.2011 16:0011.05.2011 16:25

DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=52µA
I_end=120µA

 DAQ modified so that only strips marked as good are considered when calculating the common mode correction.

  122   Wed May 11 16:28:20 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, post zupfcal106100k11.05.2011 16:0011.05.2011 16:25

DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=52µA
I_end=120µA

 DAQ modified so that only strips marked as good are considered when calculating the common mode correction.

  118   Mon Apr 11 18:37:28 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, pre zupfrun104100k11.04.2011 18:25:2811.04.2011 18:32:11

DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=50µA
I_end=95µA

 

  117   Mon Apr 11 18:25:35 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, pre zupfcal1048380011.04.2011 18:12:3811.04.2011 18:20:50

DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_single_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=26µA
I_end=48µA

 

  106   Sat Oct 9 15:29:09 2010 Markus FriedlBELLErunrun0583000009.10.2010 15:26:5009.10.2010 16:21:37

Origami1 (n-side only) + Micron1 (non-irrad)
angle scan: 73 - now with multi6 (previous run was single)
HV=100V / 35uA (beginning of run) 34uA (end of run)
cooling: chiller set to 15C

telescope run 20201

Origami p-side does not receive triggers -> disabled

origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem...

 

ELOG V3.1.5-fc6679b