ID Date Author Project Subject Run Numberdown Events StartTime EndTime
  86   Tue Oct 5 10:23:09 2010 Manfred ValentanBELLErunrun473000005.10.2010 10:21:2005.10.2010

angle scan Origami 1 and  Micron wedge 1
HV = 100V
chiller set to 14°C

angle: 0°
axis 1: 92.4 (horizontal)
axis 2: 35 (vertical)
axis 3: +7.5 (rotary table)

telescope run: 20153

  85   Tue Oct 5 10:20:30 2010 Manfred ValentanBELLErunrun4635000005.10.2010 01:00:0005.10.2010 10:16:07

angle scan Origami 1 and  Micron wedge 1
HV = 100V
chiller set to 14°C

angle: 15°
axis 1: 92.4 (horizontal)
axis 2: 35 (vertical)
axis 3: -7.5 (rotary table)

telescope run: 20152

  84   Mon Oct 4 23:59:05 2010 Manfred ValentanBELLErunrun45 04.10.2010 ??:??:??05.10.2010 00:56:48

angle scan Origami 1 and  Micron wedge 1
HV = 100V
chiller set to 14°C

angle: 45°
axis 1: 92.4 (horizontal)
axis 2: 35 (vertical)
axis 3: -37.5 (rotary table)

telescope run: 20151

  83   Mon Oct 4 23:12:16 2010 Manfred ValentanBELLErunrun443000004.10.2010 23:?:?04.10.2010 23.57.23

angle scan Origami 1 and  Micron wedge 1
HV = 100V
chiller set to 14°C

angle: 30°
axis 1: 92.4 (horizontal)
axis 2: 35 (vertical)
axis 3: -22.5 (rotary table)

telescope run: 20150

  82   Mon Oct 4 21:01:25 2010 Christian IrmlerBELLErunrun433000004.10.2010 20:59:4804.10.2010 23:04:24

angle scan Origami 1 and  Micron wedge 1
HV = 100V
chiller set to 14°C

angle: 60°
axis 1: 92.4 (horizontal)
axis 2: 35 (vertical)
axis 3: -52.5 (rotary table)

telescope run: 20149

  148   Thu May 19 11:04:04 2011 Manfred ValentanMicron BabyDUT4, source run, irrad, postzupfrun119100k19.05.2011 10:08:1419.05.2011 10:29:02

DUT4: B2Micron_2826_19_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT4/postzupf/micronbaby_multi6_irrad_postzupf.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=141µA
I_end=167µA

Every second bond zupfed...

Attachment 1: cal119_goodstrips_apv4.png
cal119_goodstrips_apv4.png
Attachment 2: cal119_goodstrips_apv5.png
cal119_goodstrips_apv5.png
Attachment 3: run119_all_hits_apv4.png
run119_all_hits_apv4.png
Attachment 4: run119_all_hits_apv5.png
run119_all_hits_apv5.png
Attachment 5: cal119_pednoise_apv4.png
cal119_pednoise_apv4.png
Attachment 6: cal119_pednoise_apv5.png
cal119_pednoise_apv5.png
  146   Thu May 19 09:44:39 2011 Manfred ValentanMicron BabyDUT3, source run, irrad, postzupfrun118100k19.05.2011 09:07:3319.05.2011 09:27:21

DUT3: B2Micron_2826_7_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT3/postzupf/micronbaby_multi6_irrad_postzupf.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=18.0µA
I_end=22.6µA

Every second bond zupfed

Attachment 1: cal118_goodstrips_apv4.png
cal118_goodstrips_apv4.png
Attachment 2: cal118_goodstrips_apv5.png
cal118_goodstrips_apv5.png
Attachment 3: run118_all_hits_apv4.png
run118_all_hits_apv4.png
Attachment 4: run118_all_hits_apv5.png
run118_all_hits_apv5.png
Attachment 5: cal118_pednoise_apv4.png
cal118_pednoise_apv4.png
Attachment 6: cal118_pednoise_apv5.png
cal118_pednoise_apv5.png
  144   Wed May 18 16:33:29 2011 Manfred ValentanMicron BabyB2Micron_2826_7_baby3, source run, unirrad, prezupfrun117100k18.05.2011 15:59:3918.05.2011 16:21:24

B2Micron_2826_7_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/7baby3/postzupf/micronbaby_multi6_postzupf.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=1.7µA

Every second bond zupfed...

Attachment 1: cal117_goodstrips_apv04.png
cal117_goodstrips_apv04.png
Attachment 2: cal117_goodstrips_apv05.png
cal117_goodstrips_apv05.png
Attachment 3: run117_all_hits_apv4.png
run117_all_hits_apv4.png
Attachment 4: run117_all_hits_apv5.png
run117_all_hits_apv5.png
Attachment 5: cal117_pednoise_apv4.png
cal117_pednoise_apv4.png
Attachment 6: cal117_pednoise_apv5.png
cal117_pednoise_apv5.png
  142   Wed May 18 15:38:29 2011 Manfred ValentanMicron BabyTRK7, source run, unirrad, postzupfrun116100k18.05.2011 15:02:0518.05.2011 15:24:07

TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/postzupf/micronbaby_multi6_postzupf.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.7µA
I_end=2.3µA

every second bond zupfed...

Attachment 1: cal116_goodstrips_apv4.png
cal116_goodstrips_apv4.png
Attachment 2: cal116_goodstrips_apv5.png
cal116_goodstrips_apv5.png
Attachment 3: run116_all_hits_apv4.png
run116_all_hits_apv4.png
Attachment 4: run116_all_hits_apv5.png
run116_all_hits_apv5.png
Attachment 5: cal116_pednoise_apv4.png
cal116_pednoise_apv4.png
Attachment 6: cal116_pednoise_apv5.png
cal116_pednoise_apv5.png
  140   Wed May 18 14:42:49 2011 Manfred ValentanMicron BabyTRK6, source run, unirrad, postzupfrun115100k18.05.2011 13:53:5418.05.2011 13:53:54

TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/postzupfzupf/micronbaby_multi6_postzupf.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.7µA
I_end=1.8µA

Every second bond zupfed. However, there was a mistake and the first ~60 channels are shifted by 1, see attachment!

Attachment 1: cal115_goodstrips_apv4.png
cal115_goodstrips_apv4.png
Attachment 2: cal115_goodstrips_apv5.png
cal115_goodstrips_apv5.png
Attachment 3: run115_all_hits_apv4.png
run115_all_hits_apv4.png
Attachment 4: run115_all_hits_apv5.png
run115_all_hits_apv5.png
Attachment 5: cal115_pednoise_apv4.png
cal115_pednoise_apv4.png
Attachment 6: cal115_pednoise_apv5.png
cal115_pednoise_apv5.png
  149   Thu May 19 11:06:41 2011 Manfred ValentanMicron BabyDUT4, source run, irrad, prezupfrun114100k18.05.2011 11:57:1318.05.2011 12:13:12

DUT4: B2Micron_2826_19_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT4/prezupf/micronbaby_multi6_irrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=118µA
I_end=168µA

keine hitmaps gespeichert...

Attachment 1: cal114_pednoise_apv4.png
cal114_pednoise_apv4.png
Attachment 2: cal114_pednoise_apv5.png
cal114_pednoise_apv5.png
  137   Wed May 18 10:38:07 2011 Manfred ValentanMicron BabyDUT3, source run, irrad, prezupfrun113100k18.05.2011 10:03:1518.05.2011 10:25:14

DUT3: B2Micron_2826_7_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT3/prezupf/micronbaby_single_irrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=20µA
I_end=26µA

Attachment 1: run113_all_hits_apv4.png
run113_all_hits_apv4.png
Attachment 2: run113_all_hits_apv5.png
run113_all_hits_apv5.png
Attachment 3: cal113_pednoise_apv4.png
cal113_pednoise_apv4.png
Attachment 4: cal113_pednoise_apv5.png
cal113_pednoise_apv5.png
  134   Tue May 17 18:53:33 2011 Manfred ValentanMicron BabyB2Micron_2826_7_baby3, source run, unirrad, prezupfrun112100k17.05.2011 19:00:2117.05.2011 19:22:45

DUT candidate atoll p-stop

B2Micron_2826_7_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/7baby3/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.4µA
I_end=1.8µA

n-side: looks very good except for a few strips in the middle of APV5 -> DUT candidate

Attachment 1: run112_all_hits_apv4.png
run112_all_hits_apv4.png
Attachment 2: run112_all_hits_apv5.png
run112_all_hits_apv5.png
Attachment 3: cal112_pednoise_apv4.png
cal112_pednoise_apv4.png
Attachment 4: cal112_pednoise_apv5.png
cal112_pednoise_apv5.png
  132   Tue May 17 18:33:07 2011 Manfred ValentanMicron BabyGEW8, source run, unirrad, prezupfrun111100k17.05.2011 18:01:4117.05.2011 18:23:24

NOT usable as DUT

GEW8: B2Micron_2826_7_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/GEW8/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.6µA
I_end=2.2µA

n-side: most of zones 1 and 3 unusable

Attachment 1: run111_all_hits_apv4.png
run111_all_hits_apv4.png
Attachment 2: run111_all_hits_apv5.png
run111_all_hits_apv5.png
Attachment 3: cal111_pednoise_apv4.png
cal111_pednoise_apv4.png
Attachment 4: cal111_pednoise_apv5.png
cal111_pednoise_apv5.png
  130   Tue May 17 17:43:24 2011 Manfred ValentanMicron BabyTRK7, source run, unirrad, prezupfrun110100k17.05.2011 15:39:3717.05.2011 16:02:54

DUT candidate common p-stop

TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.8µA
I_end=2.1µA

n-side: highest 32 strips of APV5 noisy = half of zone 4. Rest okay, DUT candidate

Attachment 1: run110_all_hits_apv4.png
run110_all_hits_apv4.png
Attachment 2: run110_all_hits_apv5.png
run110_all_hits_apv5.png
Attachment 3: cal110_pednoise_apv4.png
cal110_pednoise_apv4.png
Attachment 4: cal110_pednoise_apv5.png
cal110_pednoise_apv5.png
  128   Tue May 17 14:37:23 2011 Manfred ValentanMicron BabyTRK6, source run, unirrad, prezupfrun109100k17.05.2011 14:34:3217.05.2011 15:00:02

DUT candidate combined p-stop

TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.9µA
I_end=2.4µA

n-side zone 2 several unusable strips, zone 3 & 4 32 strips each suspicious. Nevertheless DUT candidate!

Attachment 1: run109_all_hits_apv4.png
run109_all_hits_apv4.png
Attachment 2: run109_all_hits_apv5.png
run109_all_hits_apv5.png
Attachment 3: cal109_pednoise_apv4.png
cal109_pednoise_apv4.png
Attachment 4: cal109_pednoise_apv5.png
cal109_pednoise_apv5.png
  126   Tue May 17 14:01:45 2011 Manfred ValentanMicron BabyTRK2, source run, unirrad, prezupfrun108100k17.05.2011 13:28:4817.05.2011 13:51:16

No DUT candidate (atoll p-stop)

TRK2: B2Micron_2826_1_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK2/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=2µA

n-side: APV4 most strips unusable, no DUT candidate

Attachment 1: run108_all_hits_apv4.png
run108_all_hits_apv4.png
Attachment 2: run108_all_hits_apv5.png
run108_all_hits_apv5.png
Attachment 3: cal108_pednoise_apv4.png
cal108_pednoise_apv4.png
Attachment 4: cal108_pednoise_apv5.png
cal108_pednoise_apv5.png
  124   Tue May 17 13:08:08 2011 Manfred ValentanMicron BabyTRK1, source run, unirrad, prezupfrun107100k17.05.2011 12:39:3417.05.2011 13:03:05

DUT candidate common p-stop

TRK1: B2Micron_2826_1_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK1/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=2µA

n-side: half of zones 1 and 4 obsolete due to noisy strips, rest is okay. DUT Candidate

Attachment 1: run107_all_hits_apv4.png
run107_all_hits_apv4.png
Attachment 2: run107_all_hits_apv5.png
run107_all_hits_apv5.png
Attachment 3: cal107_pednoise_apv4.png
cal107_pednoise_apv4.png
Attachment 4: cal107_pednoise_apv5.png
cal107_pednoise_apv5.png
  121   Wed May 11 16:28:07 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, post zupfrun106100k11.05.2011 16:0011.05.2011 16:25

DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=52µA
I_end=120µA

 DAQ modified so that only strips marked as good are considered when calculating the common mode correction.

  118   Mon Apr 11 18:37:28 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, pre zupfrun104100k11.04.2011 18:25:2811.04.2011 18:32:11

DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=50µA
I_end=95µA

 

ELOG V3.1.5-fc6679b