Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in 2023, Page 21 of 26  Not logged in ELOG logo
ID Date Author Subject Run Number DUTdown Wafer HV Fluence Resistivity Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min
  407   Fri Jul 14 11:09:27 2023 tb-crewthreshold optimization1266RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 11:03:2114.07.2023 11:04:481
automatic log for run 1266
Comment:
masked 15 more rows, thr 1.05V
1 noisy pixel causing troubles
  408   Fri Jul 14 11:20:46 2023 tb-crewthreshold optimization1267RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 11:12:1214.07.2023 11:16:063
automatic log for run 1267
Comment:
thr 1.08V
  409   Fri Jul 14 11:34:57 2023 tb-crewthreshold optimization1268RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 11:18:1614.07.2023 11:30:1812
automatic log for run 1268
Comment:
now only rows 63 -> 54 active , thr 1.06
  410   Fri Jul 14 11:39:52 2023 tb-crewthreshold optimization1269RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 11:32:0614.07.2023 11:35:123
automatic log for run 1269
Comment:
thr 1.055, running without beam cause fans examining our setup
is a bit noisy, but not too bad, give it some beam in next run
  411   Fri Jul 14 11:59:54 2023 tb-crewthreshold optimization1270RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 11:40:2014.07.2023 11:55:1414
automatic log for run 1270
Comment:
thr 1.055
  412   Fri Jul 14 12:57:09 2023 tb-crewthreshold optimization1271RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 11:55:2414.07.2023 12:52:2957
automatic log for run 1271
Comment:
thr 1.055
  413   Fri Jul 14 13:56:09 2023 tb-crewthreshold optimization RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
now really going for Sams irradiated chip
  414   Fri Jul 14 13:57:09 2023 tb-crewirradiated1272RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 13:52:2414.07.2023 13:52:290
automatic log for run 1272
Comment:
  415   Fri Jul 14 13:57:18 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
that was noise
  416   Fri Jul 14 13:59:10 2023 tb-crewirradiated1273RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 13:53:5814.07.2023 13:54:300
automatic log for run 1273
Comment:
thr 1.4V
  417   Fri Jul 14 14:05:27 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
that was overkill, thr 1.3V it is
  418   Fri Jul 14 14:33:52 2023 tb-crewirradiated1274RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 13:55:4914.07.2023 14:29:1333
automatic log for run 1274
Comment:
thr 1.3V
  419   Fri Jul 14 14:51:11 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
change geometry btw due to montage off cooling setup
  420   Fri Jul 14 15:50:55 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
installed cooling setup
  421   Fri Jul 14 15:52:51 2023 tb-crewirradiated1275RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:45:3914.07.2023 15:48:112
automatic log for run 1275
Comment:
finding threshold: currently
  422   Fri Jul 14 15:53:40 2023 tb-crewirradiated1276RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:48:5414.07.2023 15:49:000
automatic log for run 1276
Comment:
finding threshold: currently
  423   Fri Jul 14 15:54:43 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
thr 1.20V is noise
  424   Fri Jul 14 15:57:53 2023 tb-crewirradiated1277RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:50:2114.07.2023 15:53:132
automatic log for run 1277
Comment:
thr 1.25V
  425   Fri Jul 14 16:22:32 2023 tb-crewirradiated1278RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:59:1514.07.2023 16:17:5218
automatic log for run 1278
Comment:
thr 1.25V
  426   Fri Jul 14 16:25:20 2023 tb-crewirradiated1279RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 16:18:3114.07.2023 16:20:392
automatic log for run 1279
Comment:
thr 1.225V, -8.6 deg C
ELOG V3.1.5-fc6679b