Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in 2023, Page 13 of 26  Not logged in ELOG logo
ID Date Author Subjectdown Run Number DUT Wafer HV Fluence Resistivity Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min
  403   Fri Jul 14 10:48:46 2023 tb-crewproper data taking RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood   
thr 1.08V is noise
  404   Fri Jul 14 10:50:32 2023 tb-crewproper data taking1263RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 10:45:3114.07.2023 10:45:520
automatic log for run 1263
Comment:
  405   Fri Jul 14 10:55:25 2023 tb-crewproper data taking1264RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 10:49:3814.07.2023 10:50:451
automatic log for run 1264
Comment:
thr 1.1 seems to be not in noise
  414   Fri Jul 14 13:57:09 2023 tb-crewirradiated1272RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 13:52:2414.07.2023 13:52:290
automatic log for run 1272
Comment:
  415   Fri Jul 14 13:57:18 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
that was noise
  416   Fri Jul 14 13:59:10 2023 tb-crewirradiated1273RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 13:53:5814.07.2023 13:54:300
automatic log for run 1273
Comment:
thr 1.4V
  417   Fri Jul 14 14:05:27 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
that was overkill, thr 1.3V it is
  418   Fri Jul 14 14:33:52 2023 tb-crewirradiated1274RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 13:55:4914.07.2023 14:29:1333
automatic log for run 1274
Comment:
thr 1.3V
  419   Fri Jul 14 14:51:11 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
change geometry btw due to montage off cooling setup
  420   Fri Jul 14 15:50:55 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
installed cooling setup
  421   Fri Jul 14 15:52:51 2023 tb-crewirradiated1275RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:45:3914.07.2023 15:48:112
automatic log for run 1275
Comment:
finding threshold: currently
  422   Fri Jul 14 15:53:40 2023 tb-crewirradiated1276RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:48:5414.07.2023 15:49:000
automatic log for run 1276
Comment:
finding threshold: currently
  423   Fri Jul 14 15:54:43 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
thr 1.20V is noise
  424   Fri Jul 14 15:57:53 2023 tb-crewirradiated1277RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:50:2114.07.2023 15:53:132
automatic log for run 1277
Comment:
thr 1.25V
  425   Fri Jul 14 16:22:32 2023 tb-crewirradiated1278RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:59:1514.07.2023 16:17:5218
automatic log for run 1278
Comment:
thr 1.25V
  426   Fri Jul 14 16:25:20 2023 tb-crewirradiated1279RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 16:18:3114.07.2023 16:20:392
automatic log for run 1279
Comment:
thr 1.225V, -8.6 deg C
  427   Fri Jul 14 16:26:16 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
thr 1.225V, -8.6 deg C, was running in noise, deactivated lower 30 rows
  428   Fri Jul 14 16:45:29 2023 tb-crewirradiated1280RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 16:21:4714.07.2023 16:40:4919
automatic log for run 1280
Comment:
thr 1.225V, -8.6 deg C
  429   Fri Jul 14 17:32:50 2023 tb-crewirradiated1281RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 16:41:4814.07.2023 17:28:1046
automatic log for run 1281
Comment:
thr 1.2V, -1 deg C
  430   Fri Jul 14 17:50:57 2023 tb-crewirradiated1282RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 17:29:3114.07.2023 17:46:1716
automatic log for run 1282
Comment:
thr 1.17V, -0.6 deg C
ELOG V3.1.5-fc6679b