Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in 2023, Page 12 of 26  Not logged in ELOG logo
ID Date Author Subjectdown Run Number DUT Wafer HV Fluence Resistivity Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min
  247   Sat Jul 8 15:10:30 2023 tb-crewsearching correlations1015RD50-MPW3unknown unirradiated1.9K4.2 electronUnknown08.07.2023 15:03:3108.07.2023 15:06:092
automatic log for run 1015
Comment:
  248   Sat Jul 8 15:13:52 2023 tb-crewsearching correlations1016RD50-MPW3unknown unirradiated1.9K4.2 electronUnknown08.07.2023 15:07:1308.07.2023 15:09:312
automatic log for run 1016
Comment:
  249   Sat Jul 8 16:03:43 2023 tb-crewsearching correlations1017RD50-MPW3unknown unirradiated1.9K4.2 electronUnknown08.07.2023 15:10:3408.07.2023 15:59:2348
automatic log for run 1017
Comment:
  386   Thu Jul 13 17:34:27 2023 tb-crewproper data taking1248RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood13.07.2023 16:23:5113.07.2023 17:29:5065
automatic log for run 1248
Comment:
  387   Thu Jul 13 17:35:31 2023 tb-crewproper data taking RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood   
moving telescopes back closer together as "gbl" tracking seems to have a problem with the new geometry (or we are underestimating material budget of our DUT)
  388   Thu Jul 13 18:12:26 2023 tb-crewproper data taking1249RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood13.07.2023 17:51:4513.07.2023 18:07:4916
automatic log for run 1249
Mit TLU-timewindow [-115us, +115us] Efficiency von ~52%
  389   Thu Jul 13 18:26:34 2023 tb-crewproper data taking RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood   
disconnected piggy
  390   Thu Jul 13 21:02:45 2023 tb-crewproper data taking1250RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood13.07.2023 18:18:0713.07.2023 20:58:08160
automatic log for run 1250
Comment:
  391   Thu Jul 13 22:03:55 2023 tb-crewproper data taking1251RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood13.07.2023 20:58:1613.07.2023 21:59:1761
automatic log for run 1251
Comment:
  392   Fri Jul 14 09:06:48 2023 tb-crewproper data taking1252RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 00:01:1914.07.2023 09:02:09540
automatic log for run 1252
Comment:
  393   Fri Jul 14 09:45:00 2023 tb-crewproper data taking1253RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 09:20:0214.07.2023 09:40:2020
automatic log for run 1253
Comment:
  394   Fri Jul 14 09:47:03 2023 tb-crewproper data taking RD50-MPW3unknown91unirradiated1.9K5.6Low Flux LowelectronGood   
Petra is most likely causing our efficiency drops in time, testing now if timeshift is rate dependent (see energy)
  395   Fri Jul 14 10:07:12 2023 tb-crewproper data taking1254RD50-MPW3unknown91unirradiated1.9K5.6Low Flux LowelectronGood14.07.2023 09:41:1814.07.2023 10:02:3321
automatic log for run 1254
Comment:
  396   Fri Jul 14 10:14:05 2023 tb-crewproper data taking1255RD50-MPW3unknown91unirradiated1.9K5.2Low Flux LowelectronGood14.07.2023 10:03:0014.07.2023 10:09:256
automatic log for run 1255
Comment:
  397   Fri Jul 14 10:21:12 2023 tb-crewproper data taking1256RD50-MPW3unknown91unirradiated1.9K4.8Low Flux LowelectronGood14.07.2023 10:09:4714.07.2023 10:16:336
automatic log for run 1256
Comment:
  398   Fri Jul 14 10:29:10 2023 tb-crewproper data taking RD50-MPW3unknown91unirradiated1.9K4.8Low Flux LowelectronGood   
reduced thr to 1.15 and deactivated rows, trying to go as low with thr as possible without noise for efficiency
  399   Fri Jul 14 10:32:49 2023 tb-crewproper data taking1257RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 10:25:4114.07.2023 10:28:102
automatic log for run 1257
Comment:
reduced thr to 1.15 and deactivated rows, trying to go as low with thr as possible without noise for efficiency
  400   Fri Jul 14 10:37:04 2023 tb-crewproper data taking1258RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 10:29:4114.07.2023 10:32:242
automatic log for run 1258
Comment:
reduced thr to 1.12
  401   Fri Jul 14 10:46:29 2023 tb-crewproper data taking1261RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 10:40:1114.07.2023 10:41:501
automatic log for run 1261
Comment:
  402   Fri Jul 14 10:48:12 2023 tb-crewproper data taking1262RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 10:43:1514.07.2023 10:43:330
automatic log for run 1262
Comment:
ELOG V3.1.5-fc6679b