Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in 2024, Page 2 of 28  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Fluence Beam Energy Data t-Start t-Stop Duration_mindown
  77   Tue Apr 23 22:00:19 2024 tb-crewbasic "best" threshold / HV settings58Wxxx topsideunirradiated4.2Unknown23.04.2024 21:54:4423.04.2024 22:00:365
automatic log for run 58
Comment:
small check run
  311   Fri Apr 26 11:27:37 2024 tb-crewbst thr runs288W3 NIKHEFunirradiated4.2Unknown26.04.2024 11:22:1826.04.2024 11:27:565
automatic log for run 288
Comment:
calibrated TDACs, HV= -190V (efficiency seems to be a bit lower than HEPHY backside)
  313   Fri Apr 26 12:01:17 2024 tb-crewrotation 20deg290W3 NIKHEFunirradiated4.2Unknown26.04.2024 11:56:2726.04.2024 12:01:365
automatic log for run 290
Comment:
test run
  70   Tue Apr 23 18:20:06 2024 tb-crewbasic "best" threshold / HV settings52Wxxx topsideunirradiated4.2Unknown23.04.2024 17:33:3023.04.2024 18:20:2346
automatic log for run 52
Comment:
  45   Tue Apr 23 10:54:38 2024 tb-crewbasic "best" threshold / HV settings28Wxxx topsideunirradiated4.2Unknown23.04.2024 10:50:3523.04.2024 10:54:554
automatic log for run 28
Comment:
switched to triggering on scintillators now
corrlations without ignoring anything
  199   Wed Apr 24 15:25:21 2024 tb-crewHV scan186Wxxx topsideunirradiated4.2Unknown24.04.2024 15:21:1524.04.2024 15:25:394
automatic log for run 186
Comment:
running HV scan manually (-210V, -50uA)
  205   Wed Apr 24 15:44:06 2024 tb-crewHV scan191Wxxx topsideunirradiated4.2Unknown24.04.2024 15:39:3124.04.2024 15:44:234
automatic log for run 191
Comment:
back to HV -190V, too noisy
  371   Fri Apr 26 23:21:13 2024 tb-crewHV scan (hi range)333W3 LIVunirradiated4.2Unknown26.04.2024 23:17:1626.04.2024 23:21:334
automatic log for run 333
Comment:
telepix masking happening
  380   Sat Apr 27 11:07:27 2024 tb-crewHV scan (hi range)337W8 LIVunirradiated4.2Unknown27.04.2024 10:28:2427.04.2024 11:07:4739
automatic log for run 337
Comment:
trimming done now
  15   Mon Apr 22 17:08:30 2024 tb-crew1t tests5Wxxx topsideunirradiated4.2Unknown22.04.2024 16:30:2322.04.2024 17:08:4738
automatic log for run 5
Comment:
longer alignment run
  43   Tue Apr 23 10:46:14 2024 tb-crewbasic "best" threshold / HV settings26Wxxx topsideunirradiated4.2Unknown23.04.2024 10:09:2123.04.2024 10:46:3137
automatic log for run 26
Comment:
NOT ignoring only MPW4
  23   Mon Apr 22 19:52:25 2024 tb-crewbasic "best" threshold / HV settings10Wxxx topsideunirradiated4.2Unknown22.04.2024 19:49:3222.04.2024 19:52:423
automatic log for run 10
Comment:
  27   Mon Apr 22 22:48:19 2024 tb-crewbasic "best" threshold / HV settings13Wxxx topsideunirradiated4.2Unknown22.04.2024 22:45:1322.04.2024 22:48:353
automatic log for run 13
Comment:
  36   Tue Apr 23 09:43:02 2024 tb-crewbasic "best" threshold / HV settings19Wxxx topsideunirradiated4.2Unknown23.04.2024 09:39:3723.04.2024 09:43:193
automatic log for run 19
Comment:
not ignoring DUT2 (adenium)
  39   Tue Apr 23 09:59:57 2024 tb-crewbasic "best" threshold / HV settings22Wxxx topsideunirradiated4.2Unknown23.04.2024 09:57:0923.04.2024 10:00:143
automatic log for run 22
Comment:
  50   Tue Apr 23 13:24:11 2024 tb-crewbasic "best" threshold / HV settings33Wxxx topsideunirradiated4.2Unknown23.04.2024 13:21:1823.04.2024 13:24:283
automatic log for run 33
Comment:
not ignoring anything an triggering on Telepix, Correlations still fine though...
  61   Tue Apr 23 15:42:58 2024 tb-crewbasic "best" threshold / HV settings44Wxxx topsideunirradiated4.2Unknown23.04.2024 15:39:2723.04.2024 15:43:153
automatic log for run 44
Comment:
  72   Tue Apr 23 18:24:54 2024 tb-crewbasic "best" threshold / HV settings53Wxxx topsideunirradiated4.2Unknown23.04.2024 18:21:2323.04.2024 18:25:113
automatic log for run 53
Comment:
ignoring veto again (yes desperate)
  73   Tue Apr 23 18:33:47 2024 tb-crewbasic "best" threshold / HV settings54Wxxx topsideunirradiated4.2Unknown23.04.2024 18:30:0823.04.2024 18:34:043
automatic log for run 54
Comment:
trying to replicate run14
  74   Tue Apr 23 19:16:46 2024 tb-crewbasic "best" threshold / HV settings55Wxxx topsideunirradiated4.2Unknown23.04.2024 19:13:5023.04.2024 19:17:033
automatic log for run 55
Comment:
reset the system -> 97%
ELOG V3.1.5-fc6679b