Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in 2024, Page 26 of 28  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Fluence Beam Energy Data t-Start t-Stop Duration_mindown
  13   Mon Apr 22 16:29:40 2024 tb-crew1t tests Wxxx topsideunirradiated4.2Unknown   
Correlations seen (firsttry Big grin )
  16   Mon Apr 22 17:09:04 2024 tb-crew1t tests Wxxx topsideunirradiated4.2Unknown   
we've been ignoring vetos so far
  18   Mon Apr 22 17:12:17 2024 tb-crew1t tests Wxxx topsideunirradiated4.2Unknown   
increaed monitor data
  19   Mon Apr 22 17:34:19 2024 RD50 Generic Userinitial corry conf geometry         

wrng z achses -> use later geo

  26   Mon Apr 22 22:36:44 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   
Lost correlations after run #4
  28   Mon Apr 22 22:51:40 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   
Correlations back Big grin
We have to ignore all vetos for whaever fucking reason
  31   Tue Apr 23 09:13:47 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   
Good morning
  33   Tue Apr 23 09:21:43 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   
number of tracks per event is garbage 0.05 tr/ev so far
  59   Tue Apr 23 14:27:46 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   
fixed EUDAQ config bugs
  69   Tue Apr 23 17:43:13 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   
major efficiency problems
  71   Tue Apr 23 18:21:05 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   
ignoring veto again (yes desperate)
  200   Wed Apr 24 15:27:06 2024 tb-crewHV scan Wxxx topsideunirradiated4.2Unknown   
tipped in noise with HV increase
  213   Wed Apr 24 17:01:47 2024 RD50 Generic User         

geo for rotated sample, 20 degrees still need to be added to the DUT (x -> 200)

full aligned

mask

  215   Wed Apr 24 17:34:20 2024 tb-crew"best" settings Wxxx backsideunirradiated4.2Unknown   
changed DUT
  217   Wed Apr 24 17:38:43 2024 tb-crew"best" settings Wxxx backsideunirradiated4.2Unknown   
adjusting Telepix mask
  219   Wed Apr 24 17:41:31 2024 RD50 Generic User         

initial corry  geo for  backside biased hephy

full aligned geo from run 202 with mask

  220   Wed Apr 24 17:45:49 2024 RD50 Generic User         

Corrected geo file for first DUT (hephy/ topside W3) with fixed z

full aligned from run 57 with mask

  278   Thu Apr 25 17:23:47 2024 tb-crewHV scan Wxxx backsideunirradiated4.2Unknown   
loo HV values since a bit
  283   Thu Apr 25 17:58:39 2024 tb-crewHV scan Wxxx backsideunirradiated4.2Unknown   
do not trust bias values in low HV runs, they are weird (SMU might have been stuck)
  284   Thu Apr 25 18:00:36 2024 tb-crewHV scan Wxxx backsideunirradiated4.2Unknown   
HV at -4V manually
ELOG V3.1.5-fc6679b