Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  Testbeams at MedAustron in 2025, Page 8 of 13  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Datadown t-Start t-Stop Duration_min Frontend Phantom Phantom thickness Text Attachments
  244   Sat Sep 20 21:12:30 2025 elog_producerCaribou 1.51042RD50-MPW4800 MeVLow Flux HighProtonUnknown20.09.2025 21:11:5720.09.2025 21:12:410Normal  automatic log for run 1042
Comment:
DMA debugging
 peary_config.cfgmatrix_mpw4_base.txtmpw4.conf 
  245   Sat Sep 20 21:19:04 2025 elog_producerCaribou 1.5 RD50-MPW4800 MeVLow Flux HighProtonUnknown   Normal  DMA debugging
not waiting for IOC flag
frame rate UDP vs. DMA similar now
  
  246   Sat Sep 20 21:19:29 2025 elog_producerCaribou 1.51043RD50-MPW4800 MeVLow Flux HighProtonUnknown20.09.2025 21:18:0920.09.2025 21:19:401Normal  automatic log for run 1043
Comment:
DMA debugging
 peary_config.cfgmatrix_mpw4_base.txtmpw4.conf 
  247   Sat Sep 20 21:23:52 2025 elog_producerCaribou 1.51044RD50-MPW4800 MeVLow Flux HighProtonUnknown20.09.2025 21:23:4420.09.2025 21:24:030Normal  automatic log for run 1044
Comment:
DMA debugging
 peary_config.cfgmatrix_mpw4_base.txtmpw4.conf 
  47   Sat Mar 15 04:20:39 2025 elog-producerenergy scans232TJ-Monopix283 MeVLow Flux Very LowProtonGood15.03.2025 04:13:5115.03.2025 04:21:057HVNone automatic log for run 232
Comment:
 tjmonopix2.initjmonopix2.conf 
  61   Sat Mar 15 08:52:52 2025 RD50 Generic UserAlignment Run 800MeV2Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux MediumProtonGood08:229:4078   RaMon Rate 400kHz

front sensors 200mu: ~10-20kHz
pro Streifen
  
  62   Sat Mar 15 08:58:26 2025 RD50 Generic UserAlignment Run 800MeV1Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux LowProtonGood07:4008:2040   RaMon Rate not measured

front sensors 200mu: ~40-60Hz pro
Streifen
  
  64   Sat Mar 15 10:07:28 2025 RD50 Generic UserAlignment Run 252MeV4Sandwich-iCT setup(GSI)+RaMon252.7 MeVLow Flux MediumProtonGood10:0711:4396   RaMon Rate 1MHz

front sensors 200mu: ~10-25kHz
pro Streifen
  
  65   Sat Mar 15 11:46:28 2025 RD50 Generic UserSlab Measurement 145MeV5Sandwich-iCT setup(GSI)+RaMon145.4 MeVLow Flux MediumProtonGood11:4813:1385   RaMon Rate 600kHz

front sensors 200mu: ~1kHz pro
Streifen
  
  66   Sat Mar 15 13:15:25 2025 RD50 Generic UserSlab Measurement 205MeV6Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHeliumGood13:2714:4982   RaMon Rate 1.3 MHz

Comments:

We entered the room and connected
  
  67   Sat Mar 15 15:02:39 2025 RD50 Generic UserRate testing7Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood15:0415:2521   RaMon Rate 4.5MHz

Comments:

From File 7 until 21 optional false,
  
  69   Sat Mar 15 16:50:39 2025 RD50 Generic UserSlab Test Water 1cm9Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHeliumGood16:3517:2348 Plastic Water Slabs1cmRaMon Rate: 1.3MHz   
  73   Sat Mar 15 21:25:18 2025 RD50 Generic UserSlab Test Water 5cm14Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood21:2621:5024 Plastic Water Slabs5cmRaMon rate: 4.5MHz   
  74   Sat Mar 15 21:29:28 2025 RD50 Generic UserSlab and rate testing (with Michael)13Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood20:4421:2238 Plastic Water Slabs4cmtotzeit optimieren und deadtime finden

hex wert mal 10ns deadtime

13 ab file 10 besat effort
  
  75   Sat Jun 21 14:30:29 2025 Julia Müllner800MeV systemtest 1TOF-Cal GSI800 MeVLow Flux HighProtonGood14:4515:4257   first spills were done with low flux medium,
changed to high at 14:49

again changed to medium at 14:55
  
  76   Sat Jun 21 15:43:47 2025 Julia Müllner800MeV systemtest 2TOF-Cal GSI800 MeVLow Flux HighProtonGood16:0216:2927   Threshold set to 1000

Factor 4 chosen for future runs,
80 GB in total recorded in this run
  
  78   Sat Jun 21 17:01:05 2025 Julia Müllner97.2 MeV systemtest 4TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood16:5817:1113   Data was good, we have to shuft the setup
in x direction and slightly down. Enter room
request 17:12.
  
  79   Sat Jun 21 17:13:34 2025 Julia Müllner97.2 MeV systemtest 5TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood17:3117:5423   Threshold set to 3000

moved Ripple filters back in 

100GB data collected
  
  80   Sat Jun 21 17:54:27 2025 Julia Müllner97.2 MeV systemtest 6TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood17:5618:048   Threshold set to 4000

40GB data collected
  
  81   Sat Jun 21 18:05:21 2025 Julia Müllner97.2 MeV systemtest 7TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood18:0618:2115   Threshold set to 2000

50GB data collected

Room Entry Request: 18:21
  
ELOG V3.1.5-fc6679b