Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  Testbeams at MedAustron in 2025, Page 8 of 13  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Sat Sep 20 21:12:30 2025, elog_producer, Caribou 1.5, 1042, RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, 20.09.2025 21:11:57, 20.09.2025 21:12:41, 0, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmpw4.conf
automatic log for run 1042
Comment:
DMA debugging
Entry  Sat Sep 20 21:19:04 2025, elog_producer, Caribou 1.5, , RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, , , , Normal, ,  
DMA debugging
not waiting for IOC flag
frame rate UDP vs. DMA similar now
Entry  Sat Sep 20 21:19:29 2025, elog_producer, Caribou 1.5, 1043, RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, 20.09.2025 21:18:09, 20.09.2025 21:19:40, 1, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmpw4.conf
automatic log for run 1043
Comment:
DMA debugging
not waiting for IOC flag
frame rate UDP vs. DMA similar now
Entry  Sat Sep 20 21:23:52 2025, elog_producer, Caribou 1.5, 1044, RD50-MPW4, 800 MeV, Low Flux High, Proton, Unknown, 20.09.2025 21:23:44, 20.09.2025 21:24:03, 0, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmpw4.conf
automatic log for run 1044
Comment:
DMA debugging
no data
Entry  Sat Mar 15 04:20:39 2025, elog-producer, energy scans, 232, TJ-Monopix2, 83 MeV, Low Flux Very Low, Proton, Good, 15.03.2025 04:13:51, 15.03.2025 04:21:05, 7, HV, None,  tjmonopix2.initjmonopix2.conf
automatic log for run 232
Comment:
Entry  Sat Mar 15 08:52:52 2025, RD50 Generic User, Alignment Run 800MeV, 2, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux Medium, Proton, Good, 08:22, 9:40, 78, , ,  

RaMon Rate 400kHz

front sensors 200mu: ~10-20kHz pro Streifen

Comments:

In between run, sensors were shifted by 2mm to the left (left and right in online DAQ is mirrored)

 

Entry  Sat Mar 15 08:58:26 2025, RD50 Generic User, Alignment Run 800MeV, 1, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux Low, Proton, Good, 07:40, 08:20, 40, , ,  

RaMon Rate not measured

front sensors 200mu: ~40-60Hz pro Streifen

Comments:

stopped run due to too low rate

 

Entry  Sat Mar 15 10:07:28 2025, RD50 Generic User, Alignment Run 252MeV, 4, Sandwich-iCT setup(GSI)+RaMon, 252.7 MeV, Low Flux Medium, Proton, Good, 10:07, 11:43, 96, , ,  

RaMon Rate 1MHz

front sensors 200mu: ~10-25kHz pro Streifen

Entry  Sat Mar 15 11:46:28 2025, RD50 Generic User, Slab Measurement 145MeV, 5, Sandwich-iCT setup(GSI)+RaMon, 145.4 MeV, Low Flux Medium, Proton, Good, 11:48, 13:13, 85, , ,  

RaMon Rate 600kHz

front sensors 200mu: ~1kHz pro Streifen

Comments:

change of the trigger settings inbetween, we saw inefficency on all detectors

Entry  Sat Mar 15 13:15:25 2025, RD50 Generic User, Slab Measurement 205MeV, 6, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, Good, 13:27, 14:49, 82, , ,  

RaMon Rate 1.3 MHz

Comments:

We entered the room and connected the second LAN Port to the ReadOut-PC. The Eventbuilder-parameter got changed.

Entry  Sat Mar 15 15:02:39 2025, RD50 Generic User, Rate testing, 7, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 15:04, 15:25, 21, , ,  

RaMon Rate 4.5MHz

Comments:

From File 7 until 21 optional false, and from 22 true (everything deleted)

Entry  Sat Mar 15 16:50:39 2025, RD50 Generic User, Slab Test Water 1cm, 9, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, Good, 16:35, 17:23, 48, , Plastic Water Slabs, 1cm 

RaMon Rate: 1.3MHz

Entry  Sat Mar 15 21:25:18 2025, RD50 Generic User, Slab Test Water 5cm, 14, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 21:26, 21:50, 24, , Plastic Water Slabs, 5cm 

RaMon rate: 4.5MHz

Entry  Sat Mar 15 21:29:28 2025, RD50 Generic User, Slab and rate testing (with Michael), 13, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 20:44, 21:22, 38, , Plastic Water Slabs, 4cm 

totzeit optimieren und deadtime finden

hex wert mal 10ns deadtime

13 ab file 10 besat effort
ab 52 wieder ohne best effort

600

Entry  Sat Jun 21 14:30:29 2025, Julia Müllner, 800MeV systemtest , 1, TOF-Cal GSI, 800 MeV, Low Flux High, Proton, Good, 14:45, 15:42, 57, , ,  

first spills were done with low flux medium, changed to high at 14:49

again changed to medium at 14:55

again changed to high at 15:00

30 MB pro event builder

last few spills were with the wrong threshold

thresholds were set to 2000 instead of 1000 

Entry  Sat Jun 21 15:43:47 2025, Julia Müllner, 800MeV systemtest , 2, TOF-Cal GSI, 800 MeV, Low Flux High, Proton, Good, 16:02, 16:29, 27, , ,  

Threshold set to 1000

Factor 4 chosen for future runs, 80 GB in total recorded in this run

Entry  Sat Jun 21 17:01:05 2025, Julia Müllner, 97.2 MeV systemtest , 4, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 16:58, 17:11, 13, , ,  

Data was good, we have to shuft the setup in x direction and slightly down. Enter room request 17:12.

Entry  Sat Jun 21 17:13:34 2025, Julia Müllner, 97.2 MeV systemtest , 5, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 17:31, 17:54, 23, , ,  

Threshold set to 3000

moved Ripple filters back in 

100GB data collected

Entry  Sat Jun 21 17:54:27 2025, Julia Müllner, 97.2 MeV systemtest , 6, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 17:56, 18:04, 8, , ,  

Threshold set to 4000

40GB data collected

Entry  Sat Jun 21 18:05:21 2025, Julia Müllner, 97.2 MeV systemtest , 7, TOF-Cal GSI, 97.2MeV/u, Low Flux High, Helium, Good, 18:06, 18:21, 15, , ,  

Threshold set to 2000

50GB data collected

Room Entry Request: 18:21

ELOG V3.1.5-fc6679b