ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Datadown t-Start t-Stop Duration_min Frontend Phantom Phantom thickness
  244   Sat Sep 20 21:12:30 2025 elog_producerCaribou 1.51042RD50-MPW4800 MeVLow Flux HighProtonUnknown20.09.2025 21:11:5720.09.2025 21:12:410Normal  
automatic log for run 1042
Comment:
DMA debugging
  245   Sat Sep 20 21:19:04 2025 elog_producerCaribou 1.5 RD50-MPW4800 MeVLow Flux HighProtonUnknown   Normal  
DMA debugging
not waiting for IOC flag
frame rate UDP vs. DMA similar now
  246   Sat Sep 20 21:19:29 2025 elog_producerCaribou 1.51043RD50-MPW4800 MeVLow Flux HighProtonUnknown20.09.2025 21:18:0920.09.2025 21:19:401Normal  
automatic log for run 1043
Comment:
DMA debugging
not waiting for IOC flag
frame rate UDP vs. DMA similar now
  247   Sat Sep 20 21:23:52 2025 elog_producerCaribou 1.51044RD50-MPW4800 MeVLow Flux HighProtonUnknown20.09.2025 21:23:4420.09.2025 21:24:030Normal  
automatic log for run 1044
Comment:
DMA debugging
no data
  47   Sat Mar 15 04:20:39 2025 elog-producerenergy scans232TJ-Monopix283 MeVLow Flux Very LowProtonGood15.03.2025 04:13:5115.03.2025 04:21:057HVNone 
automatic log for run 232
Comment:
  61   Sat Mar 15 08:52:52 2025 RD50 Generic UserAlignment Run 800MeV2Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux MediumProtonGood08:229:4078   

RaMon Rate 400kHz

front sensors 200mu: ~10-20kHz pro Streifen

Comments:

In between run, sensors were shifted by 2mm to the left (left and right in online DAQ is mirrored)

 

  62   Sat Mar 15 08:58:26 2025 RD50 Generic UserAlignment Run 800MeV1Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux LowProtonGood07:4008:2040   

RaMon Rate not measured

front sensors 200mu: ~40-60Hz pro Streifen

Comments:

stopped run due to too low rate

 

  64   Sat Mar 15 10:07:28 2025 RD50 Generic UserAlignment Run 252MeV4Sandwich-iCT setup(GSI)+RaMon252.7 MeVLow Flux MediumProtonGood10:0711:4396   

RaMon Rate 1MHz

front sensors 200mu: ~10-25kHz pro Streifen

  65   Sat Mar 15 11:46:28 2025 RD50 Generic UserSlab Measurement 145MeV5Sandwich-iCT setup(GSI)+RaMon145.4 MeVLow Flux MediumProtonGood11:4813:1385   

RaMon Rate 600kHz

front sensors 200mu: ~1kHz pro Streifen

Comments:

change of the trigger settings inbetween, we saw inefficency on all detectors

  66   Sat Mar 15 13:15:25 2025 RD50 Generic UserSlab Measurement 205MeV6Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHeliumGood13:2714:4982   

RaMon Rate 1.3 MHz

Comments:

We entered the room and connected the second LAN Port to the ReadOut-PC. The Eventbuilder-parameter got changed.

  67   Sat Mar 15 15:02:39 2025 RD50 Generic UserRate testing7Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood15:0415:2521   

RaMon Rate 4.5MHz

Comments:

From File 7 until 21 optional false, and from 22 true (everything deleted)

  69   Sat Mar 15 16:50:39 2025 RD50 Generic UserSlab Test Water 1cm9Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHeliumGood16:3517:2348 Plastic Water Slabs1cm

RaMon Rate: 1.3MHz

  73   Sat Mar 15 21:25:18 2025 RD50 Generic UserSlab Test Water 5cm14Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood21:2621:5024 Plastic Water Slabs5cm

RaMon rate: 4.5MHz

  74   Sat Mar 15 21:29:28 2025 RD50 Generic UserSlab and rate testing (with Michael)13Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood20:4421:2238 Plastic Water Slabs4cm

totzeit optimieren und deadtime finden

hex wert mal 10ns deadtime

13 ab file 10 besat effort
ab 52 wieder ohne best effort

600

  75   Sat Jun 21 14:30:29 2025 Julia Müllner800MeV systemtest 1TOF-Cal GSI800 MeVLow Flux HighProtonGood14:4515:4257   

first spills were done with low flux medium, changed to high at 14:49

again changed to medium at 14:55

again changed to high at 15:00

30 MB pro event builder

last few spills were with the wrong threshold

thresholds were set to 2000 instead of 1000 

  76   Sat Jun 21 15:43:47 2025 Julia Müllner800MeV systemtest 2TOF-Cal GSI800 MeVLow Flux HighProtonGood16:0216:2927   

Threshold set to 1000

Factor 4 chosen for future runs, 80 GB in total recorded in this run

  78   Sat Jun 21 17:01:05 2025 Julia Müllner97.2 MeV systemtest 4TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood16:5817:1113   

Data was good, we have to shuft the setup in x direction and slightly down. Enter room request 17:12.

  79   Sat Jun 21 17:13:34 2025 Julia Müllner97.2 MeV systemtest 5TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood17:3117:5423   

Threshold set to 3000

moved Ripple filters back in 

100GB data collected

  80   Sat Jun 21 17:54:27 2025 Julia Müllner97.2 MeV systemtest 6TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood17:5618:048   

Threshold set to 4000

40GB data collected

  81   Sat Jun 21 18:05:21 2025 Julia Müllner97.2 MeV systemtest 7TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood18:0618:2115   

Threshold set to 2000

50GB data collected

Room Entry Request: 18:21