Entry  Sat Mar 15 21:25:18 2025, RD50 Generic User, Slab Test Water 5cm, 14, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 21:26, 21:50, 24, , Plastic Water Slabs, 5cm 

RaMon rate: 4.5MHz

Entry  Sat Mar 15 21:29:28 2025, RD50 Generic User, Slab and rate testing (with Michael), 13, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 20:44, 21:22, 38, , Plastic Water Slabs, 4cm 

totzeit optimieren und deadtime finden

hex wert mal 10ns deadtime

13 ab file 10 besat effort
ab 52 wieder ohne best effort

600

Entry  Sat Dec 13 10:18:41 2025, elog_producer, Alignment, 3, Sandwich-iCT setup(GSI)+RaMon, 200 MeV/u, reduced_mixed_beam, Mixed Beam (He+C), Good, 13.12.2025 09:41:19, 13.12.2025 10:19:06, 37, Normal, None,  ramon.conf
automatic log for run 3
Comment:
alignment mixed beam - testing beam settings
trigger window: 640ns pre and 85ns post
Entry  Sat Dec 13 10:57:30 2025, elog_producer, Alignment, 4, Sandwich-iCT setup(GSI)+RaMon, 200 MeV/u, reduced_mixed_beam, Mixed Beam (He+C), Good, 13.12.2025 10:27:49, 13.12.2025 10:57:55, 30, Normal, RW3 Plate, 9cm ramon.conf
automatic log for run 4
Comment:
mixed beam - testing beam settings
trigger window: 640ns pre and 85ns post
beam spot is centered
Entry  Sat Dec 13 11:14:38 2025, elog_producer, mixed beam, 5, Sandwich-iCT setup(GSI)+RaMon, 200 MeV/u, reduced_mixed_beam, Mixed Beam (He+C), Good, 13.12.2025 10:59:00, 13.12.2025 11:15:03, 16, Normal, RW3 Plate, 9cm ramon.conf
automatic log for run 5
Comment:
10% He
310 mki
amplitude modulation lf12
trigger window: 640ns pre and 85ns post
Entry  Sat Dec 13 11:26:46 2025, elog_producer, mixed beam, 6, Sandwich-iCT setup(GSI)+RaMon, 200 MeV/u, reduced_mixed_beam, Mixed Beam (He+C), Good, 13.12.2025 11:15:29, 13.12.2025 11:27:11, 11, Normal, RW3 Plate, 9cm ramon.conf
automatic log for run 6
Comment:
20% He
300 mki
trigger window: 640ns pre and 85ns post
Entry  Sat Dec 13 11:29:15 2025, elog_producer, mixed beam, 7, Sandwich-iCT setup(GSI)+RaMon, 200 MeV/u, reduced_mixed_beam, Mixed Beam (He+C), Good, 13.12.2025 11:27:20, 13.12.2025 11:29:40, 2, Normal, RW3 Plate, 9cm ramon.conf
automatic log for run 7
Comment:
20% He
290 mki
trigger window: 640ns pre and 85ns post
Entry  Sat Dec 13 11:32:59 2025, elog_producer, mixed beam, 8, Sandwich-iCT setup(GSI)+RaMon, 200 MeV/u, reduced_mixed_beam, Mixed Beam (He+C), Good, 13.12.2025 11:30:15, 13.12.2025 11:33:24, 3, Normal, RW3 Plate, 9cm ramon.conf
automatic log for run 8
Comment:
0% He
430 mki
amplituden modulation lf12
trigger window: 640ns pre and 85ns post
TDC4 faild, powercycle everything and restart network connections
Entry  Sat Dec 13 12:26:16 2025, elog_producer, mixed beam, 9, Sandwich-iCT setup(GSI)+RaMon, 200 MeV/u, reduced_mixed_beam, Mixed Beam (He+C), Good, 13.12.2025 11:47:19, 13.12.2025 12:26:41, 39, Normal, Mixed Beam QA phantom (ICs), 17cm ramon.conf
automatic log for run 9
Comment:
xx% He
mixed beam QA test run
Entry  Sat Dec 13 12:50:47 2025, elog_producer, alignment, 10, Sandwich-iCT setup(GSI)+RaMon, 402MeV/u, Low Flux High, Helium, Good, 13.12.2025 12:42:41, 13.12.2025 12:51:12, 8, Normal, None,  ramon.conf
automatic log for run 10
Comment:
alignment run
Entry  Sat Dec 13 13:00:26 2025, elog_producer, energy calibration, 11, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 13.12.2025 12:52:23, 13.12.2025 13:00:52, 8, Normal, None,  ramon.conf
automatic log for run 11
Comment:
alignment run 205.2 MeV
Entry  Sat Dec 13 13:13:59 2025, elog_producer, energy calibration, 12, Sandwich-iCT setup(GSI)+RaMon, 177.8 MeV/u, Low Flux High, Helium, Good, 13.12.2025 13:02:49, 13.12.2025 13:14:24, 11, Normal, None,  ramon.conf
automatic log for run 12
Comment:
alignment run 177.8 MeV
Entry  Sat Dec 13 13:23:37 2025, elog_producer, energy calibration, 13, Sandwich-iCT setup(GSI)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 13.12.2025 13:16:13, 13.12.2025 13:24:02, 7, Normal, None,  ramon.conf
automatic log for run 13
Comment:
alignment run 147.2 MeV
Entry  Sat Dec 13 13:33:47 2025, elog_producer, energy calibration, 14, Sandwich-iCT setup(GSI)+RaMon, 124.4 MeV/u, Low Flux High, Helium, Good, 13.12.2025 13:24:47, 13.12.2025 13:34:13, 9, Normal, None,  ramon.conf
automatic log for run 14
Comment:
alignment run 124.4 MeV
Entry  Sat Dec 13 13:45:59 2025, elog_producer, energy calibration, 15, Sandwich-iCT setup(GSI)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 13.12.2025 13:35:12, 13.12.2025 13:46:24, 11, Normal, None,  ramon.conf
automatic log for run 15
Comment:
calibration run 97.2 MeV
Entry  Sat Dec 13 14:00:52 2025, elog_producer, energy calibration, 16, Sandwich-iCT setup(GSI)+RaMon, 73.2 MeV/u, Low Flux High, Helium, Good, 13.12.2025 13:47:23, 13.12.2025 14:01:18, 13, Normal, None,  ramon.conf
automatic log for run 16
Comment:
calibration run 73.2 MeV
Entry  Sat Dec 13 14:18:49 2025, elog_producer, energy calibration, 17, Sandwich-iCT setup(GSI)+RaMon, 63.3 MeV/u, Low Flux High, Helium, Good, 13.12.2025 14:02:30, 13.12.2025 14:19:14, 16, Normal, None,  ramon.conf
automatic log for run 17
Comment:
calibration run 63.3 MeV
Entry  Sat Dec 13 14:48:42 2025, elog_producer, energy calibration, 18, Sandwich-iCT setup(GSI)+RaMon, 200 MeV/u, reduced_mixed_beam, Mixed Beam (He+C), Crap, 13.12.2025 14:43:14, 13.12.2025 14:49:07, 5, Normal, RW3 Plate,  ramon.conf
automatic log for run 18
Comment:
2x ionization chambers
detector 4 failed (problem with HV)
Entry  Sat Dec 13 16:00:08 2025, elog_producer, energy calibration, 19, Sandwich-iCT setup(GSI)+RaMon, 200 MeV/u, Nominal, Mixed Beam (He+C), Good, 13.12.2025 15:02:15, 13.12.2025 16:00:34, 58, Normal, RW3 Plate, 11cm ramon.conf
automatic log for run 19
Comment:
2x ionization chambers
new threshold scan
1 spill 400MeV
downtime
Entry  Sat Dec 13 16:26:02 2025, elog_producer, energy calibration, 20, Sandwich-iCT setup(GSI)+RaMon, 200 MeV/u, Nominal, Mixed Beam (He+C), Good, 13.12.2025 16:13:10, 13.12.2025 16:26:28, 13, Normal, RW3 Plate, 10cm ramon.conf
automatic log for run 20
Comment:
2x ionization chambers
start only He without dogma
Starts with only C (16:24)