Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  Testbeams at MedAustron in 2025, Page 11 of 19  Not logged in ELOG logo
Entry  Sat Dec 6 17:24:05 2025, Felix Ulrich-Pur, 402MeV/u systemtest, 9, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 402MeV/u, Low Flux High, Helium, Good, 17:24, 17:45, 21, , None,  
17:43: eventbuilder restart since lots of rejected triggers 
Entry  Sat Dec 6 17:45:43 2025, Felix Ulrich-Pur, 402MeV/u systemtest, 10, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 402MeV/u, Low Flux High, Helium, Good, 17:47, 18:08, 21, , None,  
threshold = 2000
Entry  Sat Dec 6 20:29:53 2025, Felix Ulrich-Pur, 402MeV/u systemtest, 18, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 402MeV/u, Low Flux High, Helium, Good, 20:50, 21:19, 29, , None,  
2us TriggerWindow insgesamt: 640ns PostTriggerWindow und 1360 PreTriggerWindow, max 60Mb/s Events und 25Mb/s rejected pro Eventbuilder
Entry  Sat Dec 6 21:20:03 2025, Felix Ulrich-Pur, 402MeV/u systemtest, 19, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 402MeV/u, Low Flux High, Helium, Good, 21:21, 21:37, 16, , None,  
PreTriggerWindow 640ns and PostTriggerWindow 85ns

Max 70Mb/s and Droprate 6 Mb/s
Entry  Sat Dec 6 21:38:02 2025, Felix Ulrich-Pur, 402MeV/u systemtest, 20, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 402MeV/u, Low Flux High, Helium, Good, 21:41, 22:00, 19, , None,  
PreTriggerWindow 3360ns and PostTriggerWindow 640ns 

Max 100Mb/s Events and 50Mb/s rejected
Entry  Sat Dec 13 12:50:47 2025, elog_producer, alignment, 10, Sandwich-iCT setup(GSI)+RaMon, 402MeV/u, Low Flux High, Helium, Good, 13.12.2025 12:42:41, 13.12.2025 12:51:12, 8, Normal, None,  ramon.conf
automatic log for run 10
Comment:
alignment run
Entry  Sat Mar 15 02:46:47 2025, elog-producer, energy scans, , TJ-Monopix2, 252.7 MeV, Low Flux Very Low, Proton, Unknown, , , , HV, None,  
sticking with fast RO settings
Entry  Sat Mar 15 02:53:18 2025, elog-producer, energy scans, 224, TJ-Monopix2, 252.7 MeV, Low Flux Very Low, Proton, Unknown, 15.03.2025 02:49:44, 15.03.2025 02:53:44, 3, HV, None,  tjmonopix2.initjmonopix2.conf
automatic log for run 224
Comment:
Entry  Sat Mar 15 02:56:07 2025, elog-producer, energy scans, 225, TJ-Monopix2, 252.7 MeV, Low Flux Low, Proton, Unknown, , , , HV, None,  
8b10b W02R01, 1 MHz rate (low flux low)
Entry  Sat Mar 15 03:14:22 2025, elog-producer, energy scans, 226, TJ-Monopix2, 252.7 MeV, Low Flux Very Low, Proton, Unknown, , , , HV, None,  
Run 226
Entry  Sat Mar 15 03:18:15 2025, elog-producer, energy scans, 227, TJ-Monopix2, 252.7 MeV, Low Flux Very Low, Proton, Unknown, 15.03.2025 03:16:52, 15.03.2025 03:18:41, 1, HV, None,  tjmonopix2.initjmonopix2.conf
automatic log for run 227
Comment:
Entry  Sat Mar 15 10:07:28 2025, RD50 Generic User, Alignment Run 252MeV, 4, Sandwich-iCT setup(GSI)+RaMon, 252.7 MeV, Low Flux Medium, Proton, Good, 10:07, 11:43, 96, , ,  
RaMon Rate 1MHz

front sensors 200mu: ~10-25kHz pro Streifen
Entry  Sat Mar 15 13:15:25 2025, RD50 Generic User, Slab Measurement 205MeV, 6, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, Good, 13:27, 14:49, 82, , ,  
RaMon Rate 1.3 MHz

Comments:

We entered the room and connected the second LAN Port to the ReadOut-PC. The Eventbuilder-parameter got changed.
Entry  Sat Mar 15 15:02:39 2025, RD50 Generic User, Rate testing, 7, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 15:04, 15:25, 21, , ,  
RaMon Rate 4.5MHz

Comments:

From File 7 until 21 optional false, and from 22 true (everything deleted)
Entry  Sat Mar 15 15:26:08 2025, RD50 Generic User, Rate testing, 8, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 15:31, 16:30, 59, , ,  
RaMon Rate: 1.3MHz

Comments:

Tested different evenbuilder settings which made things worse, probably switch is the bottleneck, changed rate settings inbetween, requires sergey
Entry  Sat Mar 15 16:50:39 2025, RD50 Generic User, Slab Test Water 1cm, 9, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, Good, 16:35, 17:23, 48, , Plastic Water Slabs, 1cm 
RaMon Rate: 1.3MHz
Entry  Sat Mar 15 17:30:18 2025, RD50 Generic User, Slab Test Water 2cm, 10, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 17:30, 18:24, 54, , Plastic Water Slabs, 2cm 
RaMon Rate 1.5 MHz
Entry  Sat Mar 15 18:37:36 2025, RD50 Generic User, Slab Test Water 3cm, 11, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 18:41, 19:28, 47, , Plastic Water Slabs, 3cm 
RaMon Rate 1.5MHz
Entry  Sat Mar 15 19:37:42 2025, RD50 Generic User, Slab Test Water 4cm, 12, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 19:39, 20:41, 62, , Plastic Water Slabs, 4cm 
RaMon Rate 1.4MHz
Entry  Sat Mar 15 21:25:18 2025, RD50 Generic User, Slab Test Water 5cm, 14, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 21:26, 21:50, 24, , Plastic Water Slabs, 5cm 
RaMon rate: 4.5MHz
ELOG V3.1.5-fc6679b