Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-MA2018
testbeam-MA2019
testbeam-MA2020
testbeam-MA2021
testbeam-MA2023
testbeam-MA2024
testbeam-MA2025
Testbeams at MedAustron in 2025, Page 10 of 13
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
common
DSSD-Tracker
RD50-MPW4
TJ-Monopix2
TOF-Cal GSI
RaMon
TOF-Cal GSI \(TRB)+DOGMA setup\(diamond+LGAD)+RaMon
Sandwich-iCT setup\(GSI)+RaMon
-- Beam Energy --
800 MeV
252.7 MeV
194.3 MeV
175.3 MeV
145.4 MeV
100.4 MeV
83 MeV
62.4 MeV
115.7MeV
205.2 MeV/u
177.8 MeV/u
147.2 MeV/u
124.4 MeV/u
97.2MeV/u
73.2 MeV/u
63.3 MeV/u
402MeV/u
247 Entries
Goto page
Previous
1
,
2
,
3
...
9
, 10,
11
,
12
,
13
Next
All
ID
Date
Author
Subject
Run Number
DUT
Beam Energy
Rate Setting
Particle Type
Data
t-Start
t-Stop
Duration_min
Frontend
Phantom
Phantom thickness
Text
246
Sat Sep 20 21:19:29 2025
elog_producer
Caribou 1.5
1043
RD50-MPW4
800 MeV
Low Flux High
Proton
Unknown
20.09.2025 21:18:09
20.09.2025 21:19:40
1
Normal
automatic log for run 1043
Comment:
DMA debugging
247
Sat Sep 20 21:23:52 2025
elog_producer
Caribou 1.5
1044
RD50-MPW4
800 MeV
Low Flux High
Proton
Unknown
20.09.2025 21:23:44
20.09.2025 21:24:03
0
Normal
automatic log for run 1044
Comment:
DMA debugging
66
Sat Mar 15 13:15:25 2025
RD50 Generic User
Slab Measurement 205MeV
6
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
Good
13:27
14:49
82
RaMon Rate 1.3 MHz
Comments:
We entered the room and connected
67
Sat Mar 15 15:02:39 2025
RD50 Generic User
Rate testing
7
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux High
Helium
Good
15:04
15:25
21
RaMon Rate 4.5MHz
Comments:
From File 7 until 21 optional false,
68
Sat Mar 15 15:26:08 2025
RD50 Generic User
Rate testing
8
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
15:31
16:30
59
RaMon Rate: 1.3MHz
Comments:
Tested different evenbuilder settings
69
Sat Mar 15 16:50:39 2025
RD50 Generic User
Slab Test Water 1cm
9
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
Good
16:35
17:23
48
Plastic Water Slabs
1cm
RaMon Rate: 1.3MHz
70
Sat Mar 15 17:30:18 2025
RD50 Generic User
Slab Test Water 2cm
10
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
17:30
18:24
54
Plastic Water Slabs
2cm
RaMon Rate 1.5 MHz
71
Sat Mar 15 18:37:36 2025
RD50 Generic User
Slab Test Water 3cm
11
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
18:41
19:28
47
Plastic Water Slabs
3cm
RaMon Rate 1.5MHz
72
Sat Mar 15 19:37:42 2025
RD50 Generic User
Slab Test Water 4cm
12
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
19:39
20:41
62
Plastic Water Slabs
4cm
RaMon Rate 1.4MHz
73
Sat Mar 15 21:25:18 2025
RD50 Generic User
Slab Test Water 5cm
14
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux High
Helium
Good
21:26
21:50
24
Plastic Water Slabs
5cm
RaMon rate: 4.5MHz
74
Sat Mar 15 21:29:28 2025
RD50 Generic User
Slab and rate testing (with Michael)
13
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux High
Helium
Good
20:44
21:22
38
Plastic Water Slabs
4cm
totzeit optimieren und deadtime finden
hex wert mal 10ns deadtime
13 ab file 10 besat effort
77
Sat Jun 21 16:30:44 2025
Julia Müllner
205.2 MeV systemtest
3
TOF-Cal GSI
205.2 MeV/u
Low Flux High
Helium
Unknown
16:38
16:57
19
Threshold set to 5000
dead channels on last LGAD, changed
trigger from LGAD 12 to LGAD 11
78
Sat Jun 21 17:01:05 2025
Julia Müllner
97.2 MeV systemtest
4
TOF-Cal GSI
97.2MeV/u
Low Flux High
Helium
Good
16:58
17:11
13
Data was good, we have to shuft the setup
in x direction and slightly down. Enter room
request 17:12.
79
Sat Jun 21 17:13:34 2025
Julia Müllner
97.2 MeV systemtest
5
TOF-Cal GSI
97.2MeV/u
Low Flux High
Helium
Good
17:31
17:54
23
Threshold set to 3000
moved Ripple filters back in
100GB data collected
80
Sat Jun 21 17:54:27 2025
Julia Müllner
97.2 MeV systemtest
6
TOF-Cal GSI
97.2MeV/u
Low Flux High
Helium
Good
17:56
18:04
8
Threshold set to 4000
40GB data collected
81
Sat Jun 21 18:05:21 2025
Julia Müllner
97.2 MeV systemtest
7
TOF-Cal GSI
97.2MeV/u
Low Flux High
Helium
Good
18:06
18:21
15
Threshold set to 2000
50GB data collected
Room Entry Request: 18:21
82
Sat Jun 21 18:22:28 2025
Julia Müllner
73.2 MeV systemtest
8
TOF-Cal GSI
73.2 MeV/u
Low Flux High
Helium
Crap
19:10
19:21
11
new callibration was done, dimanond detector
connected to readout
Threshold = 4000
83
Sat Jun 21 19:22:45 2025
Julia Müllner
73.2 MeV systemtest
9
TOF-Cal GSI
73.2 MeV/u
Low Flux High
Helium
Good
19:23
19:35
12
Threshold change from 50 to 500
10GB collected
84
Sat Jun 21 19:35:59 2025
Julia Müllner
63.3 MeV systemtest
10
TOF-Cal GSI
63.3 MeV/u
Low Flux High
Helium
Good
19:37
19:53
16
85
Sat Jun 21 19:54:12 2025
Julia Müllner
124.4 MeV systemtest
11
TOF-Cal GSI
124.4 MeV/u
Low Flux High
Helium
Good
19:54
20:05
11
16GB collected