ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Typedown Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness
  246   Sat Sep 20 21:19:29 2025 elog_producerCaribou 1.51043RD50-MPW4800 MeVLow Flux HighProtonUnknown20.09.2025 21:18:0920.09.2025 21:19:401Normal  
automatic log for run 1043
Comment:
DMA debugging
not waiting for IOC flag
frame rate UDP vs. DMA similar now
  247   Sat Sep 20 21:23:52 2025 elog_producerCaribou 1.51044RD50-MPW4800 MeVLow Flux HighProtonUnknown20.09.2025 21:23:4420.09.2025 21:24:030Normal  
automatic log for run 1044
Comment:
DMA debugging
no data
  66   Sat Mar 15 13:15:25 2025 RD50 Generic UserSlab Measurement 205MeV6Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHeliumGood13:2714:4982   

RaMon Rate 1.3 MHz

Comments:

We entered the room and connected the second LAN Port to the ReadOut-PC. The Eventbuilder-parameter got changed.

  67   Sat Mar 15 15:02:39 2025 RD50 Generic UserRate testing7Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood15:0415:2521   

RaMon Rate 4.5MHz

Comments:

From File 7 until 21 optional false, and from 22 true (everything deleted)

  68   Sat Mar 15 15:26:08 2025 RD50 Generic UserRate testing8Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 15:3116:3059   

RaMon Rate: 1.3MHz

Comments:

Tested different evenbuilder settings which made things worse, probably switch is the bottleneck, changed rate settings inbetween, requires sergey

  69   Sat Mar 15 16:50:39 2025 RD50 Generic UserSlab Test Water 1cm9Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHeliumGood16:3517:2348 Plastic Water Slabs1cm

RaMon Rate: 1.3MHz

  70   Sat Mar 15 17:30:18 2025 RD50 Generic UserSlab Test Water 2cm10Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 17:3018:2454 Plastic Water Slabs2cm

RaMon Rate 1.5 MHz

  71   Sat Mar 15 18:37:36 2025 RD50 Generic UserSlab Test Water 3cm11Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 18:4119:2847 Plastic Water Slabs3cm

RaMon Rate 1.5MHz

  72   Sat Mar 15 19:37:42 2025 RD50 Generic UserSlab Test Water 4cm12Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 19:3920:4162 Plastic Water Slabs4cm

RaMon Rate 1.4MHz

  73   Sat Mar 15 21:25:18 2025 RD50 Generic UserSlab Test Water 5cm14Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood21:2621:5024 Plastic Water Slabs5cm

RaMon rate: 4.5MHz

  74   Sat Mar 15 21:29:28 2025 RD50 Generic UserSlab and rate testing (with Michael)13Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood20:4421:2238 Plastic Water Slabs4cm

totzeit optimieren und deadtime finden

hex wert mal 10ns deadtime

13 ab file 10 besat effort
ab 52 wieder ohne best effort

600

  77   Sat Jun 21 16:30:44 2025 Julia Müllner205.2 MeV systemtest 3TOF-Cal GSI205.2 MeV/uLow Flux HighHeliumUnknown16:3816:5719   

Threshold set to 5000

dead channels on last LGAD, changed trigger from LGAD 12 to LGAD 11

  78   Sat Jun 21 17:01:05 2025 Julia Müllner97.2 MeV systemtest 4TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood16:5817:1113   

Data was good, we have to shuft the setup in x direction and slightly down. Enter room request 17:12.

  79   Sat Jun 21 17:13:34 2025 Julia Müllner97.2 MeV systemtest 5TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood17:3117:5423   

Threshold set to 3000

moved Ripple filters back in 

100GB data collected

  80   Sat Jun 21 17:54:27 2025 Julia Müllner97.2 MeV systemtest 6TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood17:5618:048   

Threshold set to 4000

40GB data collected

  81   Sat Jun 21 18:05:21 2025 Julia Müllner97.2 MeV systemtest 7TOF-Cal GSI97.2MeV/uLow Flux HighHeliumGood18:0618:2115   

Threshold set to 2000

50GB data collected

Room Entry Request: 18:21

  82   Sat Jun 21 18:22:28 2025 Julia Müllner73.2 MeV systemtest 8TOF-Cal GSI73.2 MeV/uLow Flux HighHeliumCrap19:1019:2111   

new callibration was done, dimanond detector connected to readout

Threshold = 4000

thresholds were too low -> run was canceled

  83   Sat Jun 21 19:22:45 2025 Julia Müllner73.2 MeV systemtest 9TOF-Cal GSI73.2 MeV/uLow Flux HighHeliumGood19:2319:3512   

Threshold change from 50 to 500

10GB collected

  84   Sat Jun 21 19:35:59 2025 Julia Müllner63.3 MeV systemtest 10TOF-Cal GSI63.3 MeV/uLow Flux HighHeliumGood19:3719:5316   
  85   Sat Jun 21 19:54:12 2025 Julia Müllner124.4 MeV systemtest 11TOF-Cal GSI124.4 MeV/uLow Flux HighHeliumGood19:5420:0511   

16GB collected