Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  Testbeams at MedAustron in 2025  Not logged in ELOG logo
Message ID: 18     Entry time: Fri Mar 14 22:41:04 2025
Author: elog-producer 
Subject: 1st tests with beam 
Run Number: 202 
DUT: TJ-Monopix2 
Beam Energy: 800 MeV 
Rate Setting: Low Flux Very Low 
Particle Type: Proton 
Data: Unknown 
t-Start: 14.03.2025 22:38:51 
t-Stop: 14.03.2025 22:41:30 
Duration_min:
Frontend: HV 
Phantom: None 
Phantom thickness:  
automatic log for run 202
Comment:
Attachment 1: tjmonopix2.ini  3 kB  | Hide | Hide all
# example init file: Ex0.ini
[LogCollector.log]
EULOG_GUI_LOG_FILE_PATTERN = $12D.log

[Producer.tracker_irgendwas]

[Producer.aida_tlu]
initid= 20210115
verbose = 1
ConnectionFile= "file:///home/pct/frameworks/trackereudaq/user/tlu/misc/aida_tlu/aida_tlu_connection.xml"
#ConnectionFile= "file:///home/tlu-ma/latesteudaq/eudaq/user/tlu/misc/aida_tlu/aida_tlu_connection.xml" #for TLU MAUS
DeviceName = "aida_tlu.controlhub"
#DeviceName = "aida_tlu.udp"
TLUmod = "1e"
# number of HDMI inputs, leave 4 even if you only use fewer inputs
nDUTs = 4
nTrgIn = 6
# 0= False (Internal Reference OFF), 1= True
intRefOn = 0
VRefInt = 2.5
VRefExt = 1.3
# I2C address of the bus expander on Enclustra FPGA
I2C_COREEXP_Addr = 0x21
# I2C address of the Si5345
I2C_CLK_Addr = 0x68
# I2C address of 1st AD5665R
I2C_DAC1_Addr = 0x13
# I2C address of 2nd AD5665R
I2C_DAC2_Addr = 0x1F
# address of unique Id number EEPROM
I2C_ID_Addr = 0x50
#I2C address of 1st expander PCA9539PW~/
I2C_EXP1_Addr = 0x74
#I2C address of 2st expander PCA9539PW
I2C_EXP2_Addr = 0x75
#I2C address of AD5665R on powermodule
I2C_DACModule_Addr = 0x1CnoiseTrim
# Max value for control voltage on PMTs (usually 1 V)
PMT_vCtrlMax= 1.0
#I2C address of 1st expander PCA9539PW on powermodule
I2C_EXP1Module_Addr = 0x76
#I2C address of 2nd expander PCA9539PW on powermodule
I2C_EXP2Module_Addr = 0x77


##CONFCLOCK 0= skip clock configuration, 1= configure si5345
CONFCLOCK= 1
#CLOCK_CFG_FILE = "/home/pct-eudaq/latesteudaq/trackereudaq/user/caribou/MPW3/csv/20mhz_out2.txt"
#CLOCK_CFG_FILE = "/home/tlu-ma/mpw3/configs/20mhz_out2.txt"
CLOCK_CFG_FILE = "/home/pct/frameworks/trackereudaq/user/tlu/misc/aida_tlu/aida_tlu_clk_config.txt"
#CLOCK_CFG_FILE = "~/latesteudaq/trackereudaq/user/eudet/misc/hw_conf/aida_tlu/aida_tlu_clk_config.txt" # for TLU MAUS

[LogCollector.log]
# Currently, all LogCollectors have a hardcoded runtime name: log
EULOG_GUI_LOG_FILE_PATTERN = maus_$12D.log
# the $12D will be converted a data/time string with 12 digits.

[Producer.elog1]
elog_installation = "/home/pct/frameworks/elog/elog"
elog_host = "elog.hephy.at"
elog_port = 443
elog_logbook = "testbeam-MA2025"
att_stop_time = "t-Stop"
att_start_time = "t-Start"
att_run_number = "Run Number"
att_run_duration = "Duration_min"
color = ""

#simply paste configuration of yourComment = Testbeams at MedAustron in 2025
Admin user = bergi, maks, bpilsl, FUL
Self register = 3

Attributes = Author, Subject, Run Number, DUT, Beam Energy, Rate Setting, Particle Type, Data, t-Start, t-Stop, Duration_min, Frontend, Phantom, Phantom thickness,
Options DUT = common, DSSD-Tracker, RD50-MPW4, TJ-Monopix2, TOF-Cal GSI, RaMon, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon
Extendable options = DUT, Beam Energy, Rate Setting, Phantom, Phantom Thickness
Options Data = Unknown, Good, Crap
Options Beam Energy = 800 MeV, 252.7 MeV, 194.3 MeV, 175.3 MeV, 145.4 MeV, 100.4 MeV, 83 MeV, 62.4 MeV, 115.7MeV, 205.2 MeV/u, 177.8 MeV/u, 147.2 MeV/u, 124.4 MeV/u, 97.2MeV/u, 73.2 MeV/u, 63.3 MeV/u, 402MeV/u
Options Particle Type = Proton, Carbon, Helium
Options Rate Setting = Low Flux Very Low, Low Flux Low, Low Flux Medium, Low Flux High
Options Frontend = Normal, Normal Casc, HV, HV Casc
Quick filter = Date, Subject, Run Number, DUT, Beam Energy
Options Phantom = Plastic Water Slabs, Dense Bone Slabs, None, plastic mouse
Options Phantom Thickness = 1cm, 2cm, 3cm, 4cm, 5cm

Menu commands =  List, New, Edit, Delete, Reply, Duplicate, Move to, Find, Help
List Menu commands = New, Find, Select, Logout, Config, Help  
Guest List Menu commands = Find, Login, Help  
Guest menu commands = List, Find, Login, Help

################################################################## Elog logbook
[Producer.HamegProducer]
serial_port="/dev/ttyUSB0"

##################################################################
Attachment 2: tjmonopix2.conf  4 kB  | Hide | Hide all
# example config file: Ex0.conf
[RunControl]
#pCT_STOP_RUN_AFTER_N_SECONDS = 3000000
# from the base RunControl.cc
#EUDAQ_CTRL_PRODUCER_LAST_START = my_pd0
#EUDAQ_CTRL_PRODUCER_FIRST_STOP = my_pd0
# Steer which values to display in the GUI: producerName and displayed value are seperated by a ",". 
ADDITIONAL_DISPLAY_NUMBERS = "log,_SERVER"

[Producer.aida_tlu]
## GENERAL PARAMETERS
verbose= 1
skipconf= 0
confid= 20201311
delayStart= 200  

## HDMI CONFIGURATION
#  4-bits to determine direction of HDMI pins
HDMI1_set= 0x7 #1= output (driven by TLU), 0 = input. bit 0=CONT, 1=SPARE, 2=TRIG, 3=BUSY for eudet, Busy needs to be 0. (0b0111 = 0x7)
HDMI2_set= 0x7
HDMI3_set= 0x7
HDMI4_set= 0x7
#  Clock source (0= no clock, 1= Si5345, 2= FPGA)
HDMI1_clk = 1
HDMI2_clk = 1
HDMI3_clk = 1
HDMI4_clk = 1
#  Enable/Disable clock on differential LEMO
LEMOclk = 0

## PMT POWER CONFIGURATION
PMT1_V= 0.8 #0.6363 #Szinti 4x4cm
PMT2_V= 0.8 #0.6363 #Szinti 4x4cm
PMT3_V= 0.0
PMT4_V= 0.0

## TRIGGER CONFIGURATION
trigMaskHi = 0x00000000
trigMaskLo = 0x00000008 #0x00000008 #0x00010002 #0x00000001  #8 coinc1+2
in0_STR = 6	# 0 
in0_DEL = 0	# 18
in1_STR = 6	# 0
in1_DEL = 0	# 18
in2_STR = 0	# 0
in2_DEL = 0 	# 0
in3_STR = 0
in3_DEL = 0
in4_STR = 0
in4_DEL = 0
in5_STR = 0 #streches pulse from 6.25ns (at 0) to 12.5ns
in5_DEL = 0
# Generate internal triggers (in Hz, 0= no triggers)
#InternalTriggerFreq= 50000 #4000 #00

## DISCRIMINATOR THRESHOLDS
DACThreshold0 = -0.025 #-0.025 #-0.012
DACThreshold1 = -0.012 #-0.025 #-0.012
DACThreshold2 = -0.012
DACThreshold3 = -0.12
DACThreshold4 = -0.12 #-0.0066
DACThreshold5 = -0.12

## DUT CONFIGURATION
 # DUTMask Which DUTs are on
#DUTMask= 0x3 #6 bit 0= DUT1, bit 1= DUT2, bit 2= DUT3, bit 3= DUT4
DUTMask= 0xB

 # DUTMaskMode Define AIDA (11) or EUDET (00) mode (2 bits per DUT)
DUTMaskMode= 0x3F #0x00

 # In EUDET mode: 0 = standard trigger/busy mode, 1 = raising BUSY outside handshake vetoes triggers (2 bits per DUT, 0x3= DUT 4! -backwards!)
DUTMaskModeModifier= 0x30 #0x30 #0xC0 PS: Check what this does! 0x0 würde ich hier eingeben

 # Ignore the BUSY signal for a DUT (0xF)
DUTIgnoreBusy= 0xD #ignores triggers
DUTIgnoreShutterVeto= 0x0
EnableRecordData = 1


# EnableShutterMode: 0x0. If 1, shutter mode is enabled. If 0, shutter mode is disabled.
EnableShutterMode= 0x0
# Define which input is used for shutter source [0 - 5]
ShutterSource = 5
# 32-bit counter of clocks. Set to 0 to not use internal shutter generator.
InternalShutterInterval = 0
# 32-bit counter of clocks
ShutterOnTime = 0 #start of shutter after trigger
# 32-bit counter of clocks
ShutterVetoOffTime = 0 #time after input-trigger, until first trigger is sent to output
# 32-bit counter of clocks
ShutterOffTime = 200000000 #end of shutter after trigger #200000000 = 5s (multiples of 25ns)

## DATA COLLECTOR
EUDAQ_DC= tlu_dc

## TLU MONITOR PARAMETER
FileComment="mpw3"
PlotWindowSizeinns=40e9
MinSpillTimeOnins=4.5
MinSpilldownTimeins=0.5
ThreshEvBegin=1
ThreshEvEnd=1
ThreshPartBegin=1
ThreshPartEnd=1




[LogCollector.log]
# Currently, all LogCollectors have a hardcoded runtime name: log
# nothing


[DataCollector.tlu_dc]
EUDAQ_FW=native
# the format of data file
EUDAQ_FW_PATTERN="/home/silicon/TJ-Monopix2/testbeam_03_2025/tlu/tlu_run$6R.raw"
# the name pattern of data file
# the $12D will be converted a data/time string with 12 digits.
# the $6R will be converted a run number string with 6 digits.
# the $X will be converted the suffix name of data file.
DISABLE_PRINT = 1


[Producer.tjmonopix2_W02R01]
start_column=448
stop_column=512
start_row=0
stop_row=512
scan_timeout=0
max_triggers=0
chip_config_file="/home/silicon/TJ-Monopix2/Tuning/2BDAQ_boards_test/HV_W02R01_threshold_scan_interpreted.h5"
VCLIP=255
daqboard_ip="192.168.10.23"
output_directory="/home/silicon/TJ-Monopix2/testbeam_03_2025/W02R01"
chip_sn="W02R01"
online_monitor_port="5500"

[Producer.tjmonopix2_W14R18]
start_column=448
stop_column=512
start_row=0
stop_row=512
scan_timeout=0
max_triggers=0
chip_config_file="/home/silicon/TJ-Monopix2/Tuning/2BDAQ_boards_test/HV_W14R18_threshold_scan_interpreted.h5"
VCLIP=255
daqboard_ip="192.168.12.23"
output_directory="/home/silicon/TJ-Monopix2/testbeam_03_2025/W14R18"
chip_sn="W14R18"
online_monitor_port="5700"

[Producer.HamegProducer]
hv=20
power_cycle_at_stop=1 #0=False 1=True
logging=1 #0=False 1=True
log_interval=10
logging_directory="/home/silicon/TJ-Monopix2/TJ-Monopix2-Power/Log/testbeam_prep"

[Producer.elog1]
#start_cmd = "./get_mpw4_configs.sh" # command (shell script) to execute before starting a run
files2log = "tjmonopix2.ini" #files to attach to the auto Elog entries, EUDAQ config will be logged by default
ELOG V3.1.5-fc6679b