  Testbeams at MedAustron in 2024, Page 9 of 11  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_mindown Frontend Phantom Phantom thickness
  102   Sun Aug 25 06:34:56 2024 tb-crewPiggy test44RD50-MPW4800 MeVLow Flux LowProtonUnknown25.08.2024 06:35:1325.08.2024 06:35:230Normal  
automatic log for run 44
Comment:
  133   Sun Aug 25 11:35:21 2024 tb-crewonly base67RD50-MPW4252.7 MeVLow Flux Very LowProtonUnknown25.08.2024 11:35:3325.08.2024 11:35:480Normal  
automatic log for run 67
Comment:
E-scan
  1   Sat Mar 30 06:34:39 2024 Bernhard PilslAnd a new testbeam starts :D            
  2   Sat Mar 30 06:53:31 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonUnknown   Normal  
about to start

geo and eudaq ini attached
  10   Sat Mar 30 07:59:55 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal  
currently no beam
  11   Sat Mar 30 08:05:59 2024 Christian IrmlerRD50-MPW4999           

Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4 shift: mpw4-tj-monopix2_TLU_00-000999.xml 

Previous local runs and xml files (mpw4-tj-monopix2_00-000212.xml) are unusable, because sensor L5.1.1.0 had a loose cotact and thus low gain.
Fixed by disconnecting and reconnecting.

  13   Sat Mar 30 08:34:12 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonGood   Normal  
beam should be back, there was something in the nozzle too
  14   Sat Mar 30 08:38:21 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonGood   Normal  
beam not back, fake news
  16   Sat Mar 30 08:56:25 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal  
waiting for beam
Performing MTS restart
  18   Sat Mar 30 09:15:13 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal  
moved entire setup a bit in order too better focus beam on MPW4 (hopefully)
  19   Sat Mar 30 09:25:05 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal  
bea is back Big grin
  23   Sat Mar 30 09:43:29 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normal  
max triggerof tracker set to 100
  25   Sat Mar 30 09:54:37 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normal  
correlations still there after rate change
  27   Sat Mar 30 09:59:40 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux MediumProtonGood   Normal  
changed rate
  30   Sat Mar 30 10:23:04 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normal  
changed rate to low again, too much "noise"
also moved table down and a bit to the left
  34   Sat Mar 30 10:28:42 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normal  
tracker FADC down, HV not on earlier, restart happening
  38   Sat Mar 30 11:20:13 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normal  
alignment good now
  43   Sat Mar 30 13:35:09 2024 bp, ci, hhuseful datataking RD50-MPW4800 MeVLow Flux LowProtonGood   Normal  
new users arrived
  72   Sat Jun 8 19:53:47 2024 Felix Ulrich-PurTOF CAL HADES LGADs Test High Rate1TOF-Cal GSI252.7 MeVLow Flux HighProtonGood16:0016:18    

7.5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 2.5 MHz on LGAD

  73   Sat Jun 8 19:56:37 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve2TOF-Cal GSI252.7 MeVLow Flux MediumProtonGood16:2916:47    

1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 350kHz on LGAD

TOF Calibration Curve