ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Data |
t-Start |
t-Stop |
Duration_min |
Frontend |
Phantom |
Phantom thickness |
102
|
Sun Aug 25 06:34:56 2024 |
tb-crew | Piggy test | 44 | RD50-MPW4 | 800 MeV | Low Flux Low | Proton | Unknown | 25.08.2024 06:35:13 | 25.08.2024 06:35:23 | 0 | Normal | | | automatic log for run 44
Comment: |
133
|
Sun Aug 25 11:35:21 2024 |
tb-crew | only base | 67 | RD50-MPW4 | 252.7 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 11:35:33 | 25.08.2024 11:35:48 | 0 | Normal | | | automatic log for run 67
Comment:
E-scan |
1
|
Sat Mar 30 06:34:39 2024 |
Bernhard Pilsl | And a new testbeam starts :D | | | | | | | | | | | | | |
2
|
Sat Mar 30 06:53:31 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Unknown | | | | Normal | | | about to start
geo and eudaq ini attached |
10
|
Sat Mar 30 07:59:55 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Crap | | | | Normal | | | currently no beam |
11
|
Sat Mar 30 08:05:59 2024 |
Christian Irmler | RD50-MPW4 | 999 | | | | | | | | | | | | Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4 shift: mpw4-tj-monopix2_TLU_00-000999.xml
Previous local runs and xml files (mpw4-tj-monopix2_00-000212.xml) are unusable, because sensor L5.1.1.0 had a loose cotact and thus low gain.
Fixed by disconnecting and reconnecting. |
13
|
Sat Mar 30 08:34:12 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Good | | | | Normal | | | beam should be back, there was something in the nozzle too |
14
|
Sat Mar 30 08:38:21 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Good | | | | Normal | | | beam not back, fake news |
16
|
Sat Mar 30 08:56:25 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Crap | | | | Normal | | | waiting for beam
Performing MTS restart |
18
|
Sat Mar 30 09:15:13 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Crap | | | | Normal | | | moved entire setup a bit in order too better focus beam on MPW4 (hopefully) |
19
|
Sat Mar 30 09:25:05 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Crap | | | | Normal | | | bea is back |
23
|
Sat Mar 30 09:43:29 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Low | Proton | Good | | | | Normal | | | max triggerof tracker set to 100 |
25
|
Sat Mar 30 09:54:37 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Low | Proton | Good | | | | Normal | | | correlations still there after rate change |
27
|
Sat Mar 30 09:59:40 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Medium | Proton | Good | | | | Normal | | | changed rate |
30
|
Sat Mar 30 10:23:04 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Low | Proton | Good | | | | Normal | | | changed rate to low again, too much "noise"
also moved table down and a bit to the left |
34
|
Sat Mar 30 10:28:42 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Low | Proton | Good | | | | Normal | | | tracker FADC down, HV not on earlier, restart happening |
38
|
Sat Mar 30 11:20:13 2024 |
bp, ci, hh | RD50-MPW4 | | RD50-MPW4 | 800 MeV | Low Flux Low | Proton | Good | | | | Normal | | | alignment good now |
43
|
Sat Mar 30 13:35:09 2024 |
bp, ci, hh | useful datataking | | RD50-MPW4 | 800 MeV | Low Flux Low | Proton | Good | | | | Normal | | | new users arrived |
72
|
Sat Jun 8 19:53:47 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs Test High Rate | 1 | TOF-Cal GSI | 252.7 MeV | Low Flux High | Proton | Good | 16:00 | 16:18 | | | | | 7.5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 2.5 MHz on LGAD |
73
|
Sat Jun 8 19:56:37 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs Calibrationcurve | 2 | TOF-Cal GSI | 252.7 MeV | Low Flux Medium | Proton | Good | 16:29 | 16:47 | | | | | 1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 350kHz on LGAD
TOF Calibration Curve |
|