ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_mindown Frontend Phantom Phantom thickness
  94   Sun Jun 9 01:25:26 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen23TOF-Cal GSI194.3 MeVLow Flux HighProtonGood00:3001:02    

2 cm dense bone (in isocentre)
- Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1 MHz on LGAD

interlock at 00:31 till 00:50 --> 19min break

WET measurement

  95   Sun Jun 9 01:26:56 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen24TOF-Cal GSI145.4 MeVLow Flux HighProtonGood01:0201:14    

2 cm dense bone (in isocentre)
2.1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 315 kHz on LGAD

WET measurement

  96   Sun Jun 9 01:27:38 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen25TOF-Cal GSI194.3 MeVLow Flux HighProtonGood01:1601:30    

3 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD

WET measurement

  97   Sun Jun 9 01:32:51 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen26TOF-Cal GSI145.4 MeVLow Flux HighProtonGood01:3001:45    

3 cm dense bone (in isocentre)
1.7 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 230 kHz on LGAD

WET measurement

  98   Sun Jun 9 01:48:51 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen27TOF-Cal GSI194.3 MeVLow Flux HighProtonGood01:4801:59    

4 cm dense bone (in isocentre)
2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 470 kHz on LGAD

WET measurement

  100   Sun Jun 9 02:02:16 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen28TOF-Cal GSI145.4 MeVLow Flux HighProtonGood02:0002:14    

4 cm dense bone (in isocentre)
1.4 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 175 kHz on LGAD

WET measurement

  101   Sun Jun 9 02:18:55 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen29TOF-Cal GSI194.3 MeVLow Flux HighProtonGood02:18     

5 cm dense bone (in isocentre)
1.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 350 kHz on LGAD

WET measurement

  104   Sun Aug 25 06:43:53 2024 tb-crewPiggy test RD50-MPW4800 MeVLow Flux LowProtonUnknown   Normal  
first tests, trying to get beam right beam
  106   Sun Aug 25 06:47:14 2024 tb-crewPiggy test RD50-MPW4800 MeVLow Flux Very LowProtonUnknown   Normal  
rate should be fine now
  108   Sun Aug 25 06:57:58 2024 tb-crewPiggy test RD50-MPW4800 MeVLow Flux Very LowProtonUnknown   Normal  
data is correlated
  111   Sun Aug 25 07:04:31 2024 tb-crewPiggy test RD50-MPW4800 MeVLow Flux Very LowProtonUnknown   Normal  
adjusting geometry
was a lil schief
  113   Sun Aug 25 07:43:57 2024 tb-crewPiggy test RD50-MPW4800 MeVLow Flux Very LowProtonUnknown   Normal  
DUT might have been stuck at end of last run
  122   Sun Aug 25 09:58:51 2024 tb-crewonly base RD50-MPW4800 MeVLow Flux Very LowProtonUnknown   Normal  
removed Piggy connections
Entry is currently edited by RD50 Generic User on 193.170.243.131    123   Sun Aug 25 10:02:35 2024 RD50 Generic Userinit_geo_file            

position of duts needs to be switched

  132   Sun Aug 25 11:33:21 2024 tb-crewonly base RD50-MPW4800 MeVLow Flux Very LowProtonUnknown   Normal  
back to nominal DACs and thr
  138   Sun Aug 25 13:04:26 2024 tb-crewonly base RD50-MPW462.4 MeVLow Flux Very LowProtonUnknown   Normal  
End of (promising) shift
  139   Mon Aug 26 09:18:25 2024 RD50 Generic Usergeo            

new geo file with adjusted dut position

ELOG V3.1.5-fc6679b