ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Data |
t-Start |
t-Stop |
Duration_min |
Frontend |
Phantom |
Phantom thickness |
Text |
|
184
|
Sat Dec 14 15:24:22 2024 |
Felix Ulrich-Pur | WET measurement slabs | 45 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 18:37 | 18:51 | 14 | | Dense Bone Slabs | 4cm | 4cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
194
|
Sat Dec 14 15:36:37 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 56 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 22:46 | 23:00 | 14 | | plastic mouse | | pos x=-25, posy=0
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
195
|
Sat Dec 14 15:37:26 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 57 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:02 | 23:16 | 14 | | plastic mouse | | pos x=-100, posy=0
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
215
|
Sat Dec 14 15:49:12 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 77 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:22 | 04:36 | 14 | | plastic mouse | | pos x=100, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
216
|
Sat Dec 14 15:49:32 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 78 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:36 | 04:50 | 14 | | plastic mouse | | pos x=175, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
217
|
Sat Dec 14 15:49:58 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 79 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:51 | 05:05 | 14 | | plastic mouse | | pos x=250, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
162
|
Sat Dec 14 13:35:59 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 23 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 124.4 MeV/u | Low Flux High | Helium | Good | 11:24 | 11:37 | 13 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000
5MHz with Ramon and only 500kHz |
|
171
|
Sat Dec 14 15:09:34 2024 |
Felix Ulrich-Pur | WET measurement slabs | 32 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 15:06 | 15:19 | 13 | | Plastic Water Slabs | 2cm | 2cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
177
|
Sat Dec 14 15:17:10 2024 |
Felix Ulrich-Pur | WET measurement slabs | 38 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 16:42 | 16:55 | 13 | | Plastic Water Slabs | 5cm | 5cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
178
|
Sat Dec 14 15:17:57 2024 |
Felix Ulrich-Pur | WET measurement slabs | 39 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 17:00 | 17:14 | 13 | | Dense Bone Slabs | 1cm | 1cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
186
|
Sat Dec 14 15:26:18 2024 |
Felix Ulrich-Pur | WET measurement slabs | 47 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 19:16 | 19:29 | 13 | | Dense Bone Slabs | 5cm | 5cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
196
|
Sat Dec 14 15:37:48 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 58 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:17 | 23:30 | 13 | | plastic mouse | | pos x=-175, posy=0
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
197
|
Sat Dec 14 15:39:11 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 59 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 23:33 | 23:46 | 13 | | plastic mouse | | pos x=-175, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
199
|
Sat Dec 14 15:40:09 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 61 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:09 | 00:22 | 13 | | plastic mouse | | pos x=-25, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
204
|
Sat Dec 14 15:42:32 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 66 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 01:21 | 01:34 | 13 | | plastic mouse | | pos x=250, posy=75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
213
|
Sat Dec 14 15:48:26 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 75 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 03:52 | 04:05 | 13 | | plastic mouse | | pos x=-25, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
69
|
Sat Mar 30 20:27:35 2024 |
hh, mb, ps | High statistics | 1052 | TJ-Monopix2 | 800 MeV | Low Flux Medium | Proton | Unknown | 30.03.2024 20:17:11 | 30.03.2024 20:30:02 | 12 | HV | | | automatic log for run 1052
Comment:
Back to stock veto period of 7us (100) |
|
172
|
Sat Dec 14 15:10:35 2024 |
Felix Ulrich-Pur | WET measurement slabs | 33 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 15:24 | 15:36 | 12 | | Plastic Water Slabs | 3cm | 3cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
175
|
Sat Dec 14 15:15:04 2024 |
Felix Ulrich-Pur | WET measurement slabs | 36 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 16:11 | 16:23 | 12 | | Plastic Water Slabs | 4cm | 4cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
176
|
Sat Dec 14 15:15:46 2024 |
Felix Ulrich-Pur | WET measurement slabs | 37 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 16:28 | 16:42 | 12 | | Plastic Water Slabs | 5cm | 5cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|