ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Data |
t-Start |
t-Stop |
Duration_min |
Frontend |
Phantom |
Phantom thickness |
Text |
|
209
|
Sat Dec 14 15:46:16 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 71 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 02:46 | 03:03 | 17 | | plastic mouse | | pos x=-100, posy=75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
126
|
Sun Aug 25 10:44:10 2024 |
tb-crew | only base | 61 | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 10:28:18 | 25.08.2024 10:44:37 | 16 | Normal | | | automatic log for run 61
Comment:
normal statistic run |
|
185
|
Sat Dec 14 15:25:12 2024 |
Felix Ulrich-Pur | WET measurement slabs | 46 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 18:55 | 19:11 | 16 | | Dense Bone Slabs | 4cm | 4cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
189
|
Sat Dec 14 15:30:23 2024 |
Felix Ulrich-Pur | threshold and preamp tests | 50 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 20:19 | 20:35 | 16 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 5000 (looks good, clustersize max
at ~3) |
|
190
|
Sat Dec 14 15:31:32 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 51 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 21:14 | 21:30 | 16 | | plastic mouse | | before run, mouse was aligned with lasers
and shift of beam w.r.t. sensor center was
taken into account |
|
205
|
Sat Dec 14 15:43:01 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 67 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 01:35 | 01:51 | 16 | | plastic mouse | | pos x=175, posy=75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
206
|
Sat Dec 14 15:43:45 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 68 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 01:51 | 02:07 | 16 | | plastic mouse | | pos x=100, posy=75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
210
|
Sat Dec 14 15:46:54 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 72 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 03:03 | 03:19 | 16 | | plastic mouse | | pos x=-175, posy=75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
212
|
Sat Dec 14 15:47:59 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 74 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 03:35 | 03:51 | 16 | | plastic mouse | | pos x=-100, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
9
|
Sat Mar 30 07:59:41 2024 |
bp, ci, hh | RD50-MPW4 | 1006 | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Good | 30.03.2024 07:46:50 | 30.03.2024 08:02:08 | 15 | Normal | | | automatic log for run 1006
Comment:
beautifully correlated :D |
|
116
|
Sun Aug 25 08:51:02 2024 |
tb-crew | VNFB scan | 53 | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 08:36:24 | 25.08.2024 08:51:28 | 15 | Normal | | | automatic log for run 53
Comment:
vnfb = 10 |
|
125
|
Sun Aug 25 10:26:57 2024 |
tb-crew | only base | 60 | RD50-MPW4 | 800 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 10:12:04 | 25.08.2024 10:27:24 | 15 | Normal | | | automatic log for run 60
Comment:
normal statistic run; !!! en_tb_mode was |
|
136
|
Sun Aug 25 12:39:45 2024 |
tb-crew | only base | 70 | RD50-MPW4 | 100.4 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 12:24:36 | 25.08.2024 12:40:12 | 15 | Normal | | | automatic log for run 70
Comment:
E-scan |
|
160
|
Sat Dec 14 13:31:49 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 21 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 10:41 | 10:56 | 15 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000
3.5MHz with Ramon and only 600kHz |
|
200
|
Sat Dec 14 15:40:45 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 62 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:22 | 00:37 | 15 | | plastic mouse | | pos x=25, posy=-75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
214
|
Sat Dec 14 15:48:49 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 76 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:06 | 04:21 | 15 | | plastic mouse | | pos x=25, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
165
|
Sat Dec 14 13:40:47 2024 |
Felix Ulrich-Pur | threshold and preamp tests | 26 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 63.3 MeV/u | Low Flux High | Helium | Good | 12:35 | 12:49 | 14 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 10000 (changed threshold)
Diamond: 500mA, threshold 50 |
|
179
|
Sat Dec 14 15:18:48 2024 |
Felix Ulrich-Pur | WET measurement slabs | 40 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 17:14 | 17:28 | 14 | | Dense Bone Slabs | 1cm | 1cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
182
|
Sat Dec 14 15:21:44 2024 |
Felix Ulrich-Pur | WET measurement slabs | 43 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 18:04 | 18:18 | 14 | | Dense Bone Slabs | 3cm | 3cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
183
|
Sat Dec 14 15:23:21 2024 |
Felix Ulrich-Pur | WET measurement slabs | 44 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 18:19 | 18:33 | 14 | | Dense Bone Slabs | 2cm | 3cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|