  79   Sat Jun 8 20:11:00 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve8TOF-Cal GSI83 MeVLow Flux MediumProtonGood19:4220:51    300 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 35kHz
on LGAD
  
  80   Sat Jun 8 21:41:04 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve9TOF-Cal GSI62.4 MeVLow Flux HighProtonGood20:5521:21    changed back to high due to beamsize vs
LGAD size factor
650 khz on Ramon (after 5 Layers of
  
  81   Sat Jun 8 21:42:13 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser10TOF-Cal GSI194.3 MeVLow Flux HighProtonGood21:2721:39    1cm plastic water (in isocentre)
6 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  82   Sat Jun 8 21:43:26 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser11TOF-Cal GSI145.4 MeVLow Flux HighProtonGood21:3921:48    1cm plastic water (in isocentre)
4 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  83   Sat Jun 8 21:54:59 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser12TOF-Cal GSI194.3 MeVLow Flux HighProtonGood21:5322:05    2cm plastic water (in isocentre)
5 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  84   Sat Jun 8 22:12:06 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser13TOF-Cal GSI145.4 MeVLow Flux HighProtonGood22:0522:34    2cm plastic water (in isocentre)
3.2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  85   Sat Jun 8 22:38:41 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser14TOF-Cal GSI194.3 MeVLow Flux HighProtonGood22:1922.34    3 cm plastic water (in isocentre)
4.3 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  86   Sun Jun 9 00:04:23 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser15TOF-Cal GSI194.3 MeVLow Flux HighProtonGood22:3422:50    3 cm plastic water (in isocentre)
2.6 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  88   Sun Jun 9 00:06:01 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser17TOF-Cal GSI194.3 MeVLow Flux HighProtonGood22:5323:04    4 cm plastic water (in isocentre)
3.8 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  89   Sun Jun 9 00:07:17 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser18TOF-Cal GSI145.4 MeVLow Flux HighProtonGood23:0423:20    4 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  90   Sun Jun 9 00:08:07 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser19TOF-Cal GSI194.3 MeVLow Flux HighProtonGood23:2023:30    5 cm plastic water (in isocentre)
3.7 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  91   Sun Jun 9 00:10:38 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser20TOF-Cal GSI145.4 MeVLow Flux HighProtonGood23:3100:00    5 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  92   Sun Jun 9 00:12:41 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen21TOF-Cal GSI194.3 MeVLow Flux HighProtonGood00:0000:14    1 cm dense bone (in isocentre)
4.5 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  93   Sun Jun 9 01:22:48 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen22TOF-Cal GSI145.4 MeVLow Flux HighProtonGood00:1400:23    1 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  94   Sun Jun 9 01:25:26 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen23TOF-Cal GSI194.3 MeVLow Flux HighProtonGood00:3001:02    2 cm dense bone (in isocentre)
- Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  95   Sun Jun 9 01:26:56 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen24TOF-Cal GSI145.4 MeVLow Flux HighProtonGood01:0201:14    2 cm dense bone (in isocentre)
2.1 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  96   Sun Jun 9 01:27:38 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen25TOF-Cal GSI194.3 MeVLow Flux HighProtonGood01:1601:30    3 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  97   Sun Jun 9 01:32:51 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen26TOF-Cal GSI145.4 MeVLow Flux HighProtonGood01:3001:45    3 cm dense bone (in isocentre)
1.7 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  98   Sun Jun 9 01:48:51 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen27TOF-Cal GSI194.3 MeVLow Flux HighProtonGood01:4801:59    4 cm dense bone (in isocentre)
2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  100   Sun Jun 9 02:02:16 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen28TOF-Cal GSI145.4 MeVLow Flux HighProtonGood02:0002:14    4 cm dense bone (in isocentre)
1.4 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  