  Testbeams at MedAustron in 2024, Page 6 of 11  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontenddown Phantom Phantom thickness
  67   Sat Mar 30 19:44:43 2024 hh, mb, psHigh statistics1050TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:40:2130.03.2024 19:47:106HV  
automatic log for run 1050
Comment:
Try with increased veto period of 20us (800)
  68   Sat Mar 30 20:13:29 2024 hh, mb, psHigh statistics1051TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:48:3630.03.2024 20:15:5527HV  
automatic log for run 1051
Comment:
Try with increased veto period of 20us (800)
  69   Sat Mar 30 20:27:35 2024 hh, mb, psHigh statistics1052TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 20:17:1130.03.2024 20:30:0212HV  
automatic log for run 1052
Comment:
Back to stock veto period of 7us (100)
  70   Sat Mar 30 20:46:41 2024 hh, mb, psHigh statistics1053TJ-Monopix2800 MeVLow Flux HighProtonUnknown30.03.2024 20:31:1430.03.2024 20:49:0817HV  
automatic log for run 1053
Comment:
Back to stock veto period of 7us (100)
Lets try with high
  71   Sat Mar 30 20:51:31 2024 hh, mb, psHigh statistics1054TJ-Monopix2800 MeVLow Flux HighProtonUnknown30.03.2024 20:50:5330.03.2024 20:53:583HV  
automatic log for run 1054
Comment:
Litle high settings run
  1   Sat Mar 30 06:34:39 2024 Bernhard PilslAnd a new testbeam starts :D            
  11   Sat Mar 30 08:05:59 2024 Christian IrmlerRD50-MPW4999           

Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4 shift: mpw4-tj-monopix2_TLU_00-000999.xml 

Previous local runs and xml files (mpw4-tj-monopix2_00-000212.xml) are unusable, because sensor L5.1.1.0 had a loose cotact and thus low gain.
Fixed by disconnecting and reconnecting.

  72   Sat Jun 8 19:53:47 2024 Felix Ulrich-PurTOF CAL HADES LGADs Test High Rate1TOF-Cal GSI252.7 MeVLow Flux HighProtonGood16:0016:18    

7.5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 2.5 MHz on LGAD

  73   Sat Jun 8 19:56:37 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve2TOF-Cal GSI252.7 MeVLow Flux MediumProtonGood16:2916:47    

1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 350kHz on LGAD

TOF Calibration Curve

  74   Sat Jun 8 19:57:39 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve3TOF-Cal GSI194.3 MeVLow Flux MediumProtonGood16:5117:28    

600 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 235kHz on LGAD

TOF Calibration Curve

  75   Sat Jun 8 20:05:27 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve4TOF-Cal GSI175.3 MeVLow Flux MediumProtonGood17:3117:54    

500 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 170kHz on LGAD

TOF Calibration Curve

  76   Sat Jun 8 20:07:44 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve5TOF-Cal GSI145.4 MeVLow Flux MediumProtonGood17:5518:24    

400 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 120kHz on LGAD

TOF Calibration Curve

  77   Sat Jun 8 20:08:55 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve6TOF-Cal GSI115.7MeVLow Flux MediumProtonGood18:2419:00    

400 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 65kHz on LGAD

TOF Calibration Curve

  78   Sat Jun 8 20:09:25 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve7TOF-Cal GSI100.4 MeVLow Flux MediumProtonGood19:0019:42    

300 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 65kHz on LGAD

TOF Calibration Curve

  79   Sat Jun 8 20:11:00 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve8TOF-Cal GSI83 MeVLow Flux MediumProtonGood19:4220:51    

300 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 35kHz on LGAD

TOF Calibration Curve

  80   Sat Jun 8 21:41:04 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve9TOF-Cal GSI62.4 MeVLow Flux HighProtonGood20:5521:21    

changed back to high due to beamsize vs LGAD size factor
650 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 230kHz on LGAD

TOF Calibration Curve

  81   Sat Jun 8 21:42:13 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser10TOF-Cal GSI194.3 MeVLow Flux HighProtonGood21:2721:39    

1cm plastic water (in isocentre)
6 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1.5 MHz on LGAD

WET measurement

  82   Sat Jun 8 21:43:26 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser11TOF-Cal GSI145.4 MeVLow Flux HighProtonGood21:3921:48    

1cm plastic water (in isocentre)
4 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 700 kHz on LGAD

WET measurement

  83   Sat Jun 8 21:54:59 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser12TOF-Cal GSI194.3 MeVLow Flux HighProtonGood21:5322:05    

2cm plastic water (in isocentre)
5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1.2 MHz on LGAD

WET measurement

  84   Sat Jun 8 22:12:06 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser13TOF-Cal GSI145.4 MeVLow Flux HighProtonGood22:0522:34    

2cm plastic water (in isocentre)
3.2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD

WET measurement