Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  Testbeams at MedAustron in 2024, Page 5 of 11  Not logged in ELOG logo
Entry  Sun Jun 9 00:07:17 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Wasser, 18, TOF-Cal GSI, 145.4 MeV, Low Flux High, Proton, Good, 23:04, 23:20, , , ,  
4 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 500 kHz on LGAD

WET measurement
Entry  Sun Jun 9 00:08:07 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Wasser, 19, TOF-Cal GSI, 194.3 MeV, Low Flux High, Proton, Good, 23:20, 23:30, , , ,  
5 cm plastic water (in isocentre)
3.7 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 795 kHz on LGAD

WET measurement
Entry  Sun Jun 9 00:10:38 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Wasser, 20, TOF-Cal GSI, 145.4 MeV, Low Flux High, Proton, Good, 23:31, 00:00, , , ,  
5 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 330 kHz on LGAD

14 min break with beam off (DAQ failed, had to power cycle TRB3s and all DIRICH boards-->out of synch DIRICH)
Entry  Sun Jun 9 00:12:41 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Knochen, 21, TOF-Cal GSI, 194.3 MeV, Low Flux High, Proton, Good, 00:00, 00:14, , , ,  
1 cm dense bone (in isocentre)
4.5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1.2 MHz on LGAD

WET measurement
Entry  Sun Jun 9 01:22:48 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Knochen, 22, TOF-Cal GSI, 145.4 MeV, Low Flux High, Proton, Good, 00:14, 00:23, , , ,  
1 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD

WET measurement
Entry  Sun Jun 9 01:25:26 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Knochen, 23, TOF-Cal GSI, 194.3 MeV, Low Flux High, Proton, Good, 00:30, 01:02, , , ,  
2 cm dense bone (in isocentre)
- Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1 MHz on LGAD

interlock at 00:31 till 00:50 --> 19min break
Entry  Sun Jun 9 01:26:56 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Knochen, 24, TOF-Cal GSI, 145.4 MeV, Low Flux High, Proton, Good, 01:02, 01:14, , , ,  
2 cm dense bone (in isocentre)
2.1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 315 kHz on LGAD

WET measurement
Entry  Sun Jun 9 01:27:38 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Knochen, 25, TOF-Cal GSI, 194.3 MeV, Low Flux High, Proton, Good, 01:16, 01:30, , , ,  
3 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD

WET measurement
Entry  Sun Jun 9 01:32:51 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Knochen, 26, TOF-Cal GSI, 145.4 MeV, Low Flux High, Proton, Good, 01:30, 01:45, , , ,  
3 cm dense bone (in isocentre)
1.7 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 230 kHz on LGAD

WET measurement
Entry  Sun Jun 9 01:48:51 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Knochen, 27, TOF-Cal GSI, 194.3 MeV, Low Flux High, Proton, Good, 01:48, 01:59, , , ,  
4 cm dense bone (in isocentre)
2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 470 kHz on LGAD

WET measurement
Entry  Sun Jun 9 02:02:16 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Knochen, 28, TOF-Cal GSI, 145.4 MeV, Low Flux High, Proton, Good, 02:00, 02:14, , , ,  
4 cm dense bone (in isocentre)
1.4 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 175 kHz on LGAD

WET measurement
Entry  Sun Jun 9 02:18:55 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Knochen, 29, TOF-Cal GSI, 194.3 MeV, Low Flux High, Proton, Good, 02:18, , , , ,  
5 cm dense bone (in isocentre)
1.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 350 kHz on LGAD

WET measurement
Entry  Sat Mar 30 15:02:07 2024, hh, mb, ps, 1st tests, 1027, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 14:52:54, 30.03.2024 15:04:32, 11, HV, ,  tjmonopix2.conf
automatic log for run 1027
Comment:
Entry  Sat Mar 30 15:05:28 2024, hh, mb, ps, 1st tests, 1028, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:04:47, 30.03.2024 15:07:55, 3, HV, ,  tjmonopix2.conf
automatic log for run 1028
Comment:
Entry  Sat Mar 30 15:08:33 2024, hh, mb, ps, 1st tests, 1029, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:08:26, 30.03.2024 15:11:00, 2, HV, ,  tjmonopix2.conf
automatic log for run 1029
Comment:
Entry  Sat Mar 30 15:18:29 2024, hh, mb, ps, 1st tests, 1030, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:18:21, 30.03.2024 15:20:55, 2, HV, ,  tjmonopix2.conf
automatic log for run 1030
Comment:
Entry  Sat Mar 30 15:20:37 2024, hh, mb, ps, 1st tests, 1031, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:21:51, 30.03.2024 15:23:03, 1, HV, ,  tjmonopix2.conf
automatic log for run 1031
Comment:
Entry  Sat Mar 30 15:22:15 2024, hh, mb, ps, 1st tests, 1032, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:24:02, 30.03.2024 15:24:41, 0, HV, ,  tjmonopix2.conf
automatic log for run 1032
Comment:
Entry  Sat Mar 30 15:24:44 2024, hh, mb, ps, 1st tests, 1033, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:25:06, 30.03.2024 15:27:10, 2, HV, ,  tjmonopix2.conf
automatic log for run 1033
Comment:
Entry  Sat Mar 30 15:31:41 2024, hh, mb, ps, 1st tests, 1034, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:29:49, 30.03.2024 15:34:08, 4, HV, ,  tjmonopix2.conf
automatic log for run 1034
Comment: