Sun Jun 9 01:22:48 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Knochen, 22, TOF-Cal GSI, 145.4 MeV, Low Flux High, Proton, Good, 00:14, 00:23, ,
|
1 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD
WET measurement |
Sun Jun 9 00:12:41 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Knochen, 21, TOF-Cal GSI, 194.3 MeV, Low Flux High, Proton, Good, 00:00, 00:14, ,
|
1 cm dense bone (in isocentre)
4.5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1.2 MHz on LGAD
WET measurement |
Sun Jun 9 00:10:38 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Wasser, 20, TOF-Cal GSI, 145.4 MeV, Low Flux High, Proton, Good, 23:31, 00:00, ,
|
5 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 330 kHz on LGAD
14 min break with beam off (DAQ failed, had to power cycle TRB3s and all DIRICH boards-->out of synch DIRICH)
WET measurement |
Sat Mar 30 06:34:39 2024, Bernhard Pilsl, And a new testbeam starts :D, , , , , , , , , ,
|
|
Sat Mar 30 06:53:31 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, , , , Normal
|
about to start
geo and eudaq ini attached |
Sat Mar 30 07:59:55 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, , , , Normal
|
currently no beam |
Sat Mar 30 08:05:59 2024, Christian Irmler, RD50-MPW4, 999, , , , , , , , ,
|
Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4 shift: mpw4-tj-monopix2_TLU_00-000999.xml
Previous local runs and xml files (mpw4-tj-monopix2_00-000212.xml) are unusable, because sensor L5.1.1.0 had a loose cotact and thus low gain.
Fixed by disconnecting and reconnecting. |
Sat Mar 30 08:34:12 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Good, , , , Normal
|
beam should be back, there was something in the nozzle too |
Sat Mar 30 08:38:21 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Good, , , , Normal
|
beam not back, fake news |
Sat Mar 30 08:56:25 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, , , , Normal
|
waiting for beam
Performing MTS restart |
Sat Mar 30 09:15:13 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, , , , Normal
|
moved entire setup a bit in order too better focus beam on MPW4 (hopefully) |
Sat Mar 30 09:25:05 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, , , , Normal
|
bea is back |
Sat Mar 30 09:43:29 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, , , , Normal
|
max triggerof tracker set to 100 |
Sat Mar 30 09:54:37 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, , , , Normal
|
correlations still there after rate change |
Sat Mar 30 09:59:40 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Medium, Proton, Good, , , , Normal
|
changed rate |
Sat Mar 30 10:23:04 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, , , , Normal
|
changed rate to low again, too much "noise"
also moved table down and a bit to the left |
Sat Mar 30 10:28:42 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, , , , Normal
|
tracker FADC down, HV not on earlier, restart happening |
Sat Mar 30 11:20:13 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, , , , Normal
|
alignment good now |
Sat Mar 30 13:35:09 2024, bp, ci, hh, useful datataking, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, , , , Normal
|
new users arrived |
Sun Jun 9 02:18:55 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Knochen, 29, TOF-Cal GSI, 194.3 MeV, Low Flux High, Proton, Good, 02:18, , ,
|
5 cm dense bone (in isocentre)
1.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 350 kHz on LGAD
WET measurement |
|